Product Main

Quick Details

Place of Origin: China (Mainland)

Specifications

   Anesthesia Machine BZ-607 with anesthesia ventilator


Descrition:

Aluminium alloy frame has rail, can be upgraded with functions, eg, Anesthesia Ventilator, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
Fully operated by Manual, no electricity will be required,
Fresh gas outlet is in front of frame, the user can easily connect with Jackson -Rees circuit,
Classical CO2 circle absorber is with 2 canisters, low resistance, minimum gas leakage,
With stainless table surface, 1 safety lock and 2 big drawers,
Optional: O2,N2O Yoke device. When main gas supply is failed, the backup gas supply can be automatically started.
Applications:
The Anesthesia Machine which is researched and produced by the Manufacturer is a movable unit with anesthesia function, which could be applied to closed anesthesia, semi-closed anesthesia, and semi-open anesthesia, and be applicable to Adult / Pediatric inhalation anesthesia, oxygen supply, resuscitation.

Specifications:
Tidal volume 0.50ml~1600ml
Flowmeter O2: 0.1~10L/min.
N2O(Air): 0.1~10L/min.
Hypoxic guard system, keep oxygen concentration isn`t lower than 25%
APL valve 0.5~6.0Kpa
Volume of soda lime tank (CO2 absorbing tank) 1500ml each
Circle absorber Safety valve pressure limit: 6Kpa
Good air tightness, high reliability and minor respiration impedance
With Manual/ Ventilation switch
Gas source pressure O2: 0.25Mpa~0.65MPa
N2O: 0.25Mpa~0.65MPa
Oxygen flush 25L/min~75L/min
Physical specification


Whole machine:
Length: 920mm
Width: 560mm
Height: 1440mm
Weight: 110Kg
Wheels: 100mm (diameter), 125mm (height), with brakes on the front two wheels
Environments Temperature: Working: 18-36oC
Storage: -20-55oC
Comparative humidity:
Working: 45%-75%
Storage: ≤93%
Atmosphere:
Working: 0.95~1.05 bar
Storage: 500hpa~1060hpa,
Altitude:
Working: 500 to 800 mmHg (3565 to -440m)
Storage: 375 to 800 mmHg (5860 to -440m)

Competitive Advantage:
Aluminium alloy frame has rail, can be upgraded with functions, eg, Anesthesia Ventilator, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
Fully operated by Manual, no electricity will be required,
Fresh gas outlet is in front of frame, the user can easily connect with Jackson -Rees circuit,
Classical CO2 circle absorber is with 2 canisters, low resistance, minimum gas leakage,
With stainless table surface, 1 safety lock and 2 big drawers,
Optional: O2,N2O Yoke device. When main gas supply is failed, the backup gas supply can be automatically started.

Economic anesthesia machine\