Product Main

Quick Details

Output Current: 13A
Output Frequency: 0.00~650.00Hz
Type: DC/AC Inverters
Output Voltage: 0~input voltage
Input Voltage: 380~440V
Weight: 3KG
Size: 32x20x18cm
Output Type: Triple
Model Number: VC610-4T0055G
Brand Name: invoee
Place of Origin: China (Mainland)
guarantee: 18 months
brand: invoee

Specifications

Main parameter of VC610 5.5kw CNC spindle inverter:

  1. Item: VC610-4T0055G

  2. Control mode: vector

  3. Matched motor power: 5.5kw

  4. Input frequency and voltage:380~440V,50/60Hz

  5. Rated output current: 13A

  6. Output frequency: 0.00~650.00Hz

  7. Output voltage:0~input voltage

  8. Guarantee: 3 years


VC610 55kw Vector Close Loop CNC Spindle Inverter


VC610 55kw Vector Close Loop CNC Spindle Inverter
the bottom of spindle inverter, cooling fan.

  General technical specifications for VC610 CNC spindle variable frequency drive

Items

Description

Input

Rated frequency and voltage

Three-phase: 380~440V, 50/60Hz;

Three-phase/single-phase: 220~240V, 50/60Hz

Operating range of voltage and frequency

Voltage: ±20%; frequency: ±5%

Output

Voltage

0~input voltage

Frequency

0.00~650.00Hz

over-load capacity

1min at 150% of the rated current and 1s at 200% of the rated current

Main control properties

Control mode

Vector control

Range of speed regulation

1:100

Torque characteristics

High torque output, starting torque can reach 150% at 1Hz.

Frequency accuracy

Digital setting: ±0.01%; analog setting: ±0.2%

Frequency resolution

Digital setting: 0.01Hz; analog setting: 0.1% of the max. Frequency

Start modes

3 modes: start from start frequency, start after brake and start after rotating speed tracking

Acceleration/

Deceleration modes

3 modes: straight line mode, settable S-curve mode (independently adjustable proportions of start and end sections of S-curve) and automatic acceleration and deceleration mode

Stop modes

3 modes: decelerated stop, decelerated stop+DC braking and free stop

DC braking

Start frequency of braking: 0~60.00Hz, or determined by external input terminals.

Braking time: 0.0~60.0s, or determined by external input terminals.

Braking current: 0.0~100.0% of the rated current of frequency converters

Dynamic  brake

Adjustable max.Braking torque.

Jog

Range of jog frequency: 0.00~upper limiting frequency; jog acceleration/deceleration time: 0.0~6553.5s; jog interval can be set.

Automatic voltage regulation

When input power grid  fluctuates, stability of output voltage can be kept automatically.

Fast current limit

Fast current restraining ability prevents frequent over-current trips and realize the Characteristics of excavator (output torque is kept for locked-rotor of motors).

Automatic carrier regulation

Carrier frequency can be automatically regulated to optimize system state in accordance with load characteristics.