After-sales Service Provided: | Engineers available to service machinery overseas |
---|---|
Certification: | ce |
Weight: | 500-1000kg |
Dimension(L*W*H): | option |
Power(W): | 10kw |
Voltage: | option |
Usage: | Insulation Oil |
Model Number: | TCF |
Brand Name: | Acore |
Place of Origin: | China (Mainland) |
Working Pressure: | 0.4Mpa |
Flow: | 15l/min |
Condition: | New |
Quick Details
Specifications
Application:
Frequent switching converter of transformer load tap
Changer produces free carbon and various solids, they pollute the load tap
Changer oil. Meanwhile, the oil absorbs moisture, so that insulation pressure
of oil reduces and water content increases, the insulation performance of load
Tap changer declines, further increases pollution and brings a bad cycle. So in
Order to solve this problem, we design and produce Load Tap Changer Oil Purifier.
Load Tap Changer Oil Purifier(TCF) Can works automatically when transformers is running, it has a sensor to check Solids and moisture content, when they reach the setting index, the oil Filtration system will automatically run and remove solids and water, restore Tap-oil dielectric strength and performance, increase the TCF operation safety, Reliability, greatly reducing the transformer outage times and improve Reliability.
Load Tap Changer Oil Purifier can
Completely solve the problem of insulating oil easily decomposed, aging,
Pollution of free carbon and metal debris, breakdown voltage reducing and
Dielectric properties deteriorating.
Feature
1. Breakdown voltage increases to above 75 kV/2.5mm
2. High efficiency micro-glass filter element can remove 99% of Particles 1 micron or larger
3. Water removal filter element reduce water content down to 20 ppm
4. Pressure gage to display the Pressure of filter vessels
5. Pressure switch turns the System off when filter is plugged
6. NEMA4 fully enclosed cabinet
7. Automatic Safety Shut-Down
8. Stainless steel piping