Rated Current: | Depend on Voltage |
---|---|
Rated Voltage: | 230/400V |
Rated Power: | 125kva/100kw |
Frequency: | 50Hz |
Speed: | 1500RPM |
Output Type: | AC Three Phase |
Model Number: | GPW125 |
Brand Name: | GENLITEC POWER |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Open type 100kw weichai diesel generator set
STANDARD CONFIGURATION
* Prime power from 10kva to 35kva (50Hz, 3-Phase)
* Industrial water-cooled YANGDONG diesel engine
* CHINT or DELIXI circuit breaker
* Steel base fuel tank with anti-vibration mounting
* Based 8 hours daily fuel tank
* 9dB muffler exhaust system, free-maintenance battery, user's manual
* Flexible fuel lines and lube oil drain cock
* Smartgen or Harsen digital control module
* Shrink wrap or plywood box packing method
* Kipor type ultra-silent canopy design
PRP: Prime power is available for an unlimited number of annual operating hours in variable
Load applications, in accordance with ISO8528-1.A 10% overload capability is available for a period of 1 hour within 12-hours period of operation
ESP: the Standby power rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed
Delivery time: 20-25 working days upon received your 30% deposit.
Warranty: 12 months or 1000 working hours whichever comes first.
Service and parts are available from GENLITEC POWER or distributors in your location.
TESTING ITEMS
GENLITEC POWER provides a full line of brand new and high quality products. Each and every unit is strictly factory tested before shipment.
Parts faults testing; Fuel tank pressure testing; Bolt tightening torque testing; Painting thickness testing; Voltage bearing and insulation testing; Noise testing; Loading Testing(25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.
STANDARD CONFIGURATION
* Prime power from 10kva to 35kva (50Hz, 3-Phase)
* Industrial water-cooled YANGDONG diesel engine
* CHINT or DELIXI circuit breaker
* Steel base fuel tank with anti-vibration mounting
* Based 8 hours daily fuel tank
* 9dB muffler exhaust system, free-maintenance battery, user's manual
* Flexible fuel lines and lube oil drain cock
* Smartgen or Harsen digital control module
* Shrink wrap or plywood box packing method
* Kipor type ultra-silent canopy design
PRP: Prime power is available for an unlimited number of annual operating hours in variable
Load applications, in accordance with ISO8528-1.A 10% overload capability is available for a period of 1 hour within 12-hours period of operation
ESP: the Standby power rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed
Delivery time: 20-25 working days upon received your 30% deposit.
Warranty: 12 months or 1000 working hours whichever comes first.
Service and parts are available from GENLITEC POWER or distributors in your location.
TESTING ITEMS
GENLITEC POWER provides a full line of brand new and high quality products. Each and every unit is strictly factory tested before shipment.
Parts faults testing; Fuel tank pressure testing; Bolt tightening torque testing; Painting thickness testing; Voltage bearing and insulation testing; Noise testing; Loading Testing(25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.
Model | Prime Power (PRP) | Standby Power (ESP) | Engine Model | Alternator Model | Controller Moudle | ||
kW | Kva | kW | Kva | Weichai TIANHE | Genlitec Power | Smartgen | |
GWF12(S) | 10 | 13 | 11 | 14 | SL2100ABD/16kw | GPG-10KW | HGM420 |
GWF15(S) | 12 | 15 | 13 | 17 | SL2100ABD/16kw | GPG-12KW | HGM420 |
GWF20(S) | 15 | 19 | 17 | 21 | 2100ABD/19.3kw | GPG-15KW | HGM420 |
GWF25(S) | 20 | 25 | 22 | 28 | 495D/26.5KW | GPG-20KW | HGM420 |
GWF30(S) | 24 | 30 | 26 | 33 | 4100D/30KW | GPG-24KW | HGM420 |
GWF31(S) | 25 | 31 | 28 | 34 | 495ZD/36.5KW | GPG-30KW | HGM420 |
GWF38(S) | 30 | 38 | 33 | 41 | 4100ZD/42KW | GPG-40KW | HGM420 |
GWF50(S) | 40 | 50 | 44 | 55 | 4105ZD/56KW | GPG-50KW | HGM420 |
GWF63(S) | 50 | 63 | 55 | 69 | 4105AZLD/66KW | GPG-60KW | HGM420 |
GWF75(S) | 60 | 75 | 66 | 83 | 6105ZD/84KW | GPG-75KW | HGM420 |
GWF100(S) | 80 | 100 | 88 | 110 | 6105AZLD/110KW | GPG-100KW | HGM6120 |
GWF125(S) | 100 | 125 | 110 | 138 | 6105IZLD/132KW | GPG-120KW | HGM6120 |
GWF150(S) | 120 | 150 | 132 | 165 | 6110ZLD/165KW | GPG-144KW | HGM6120 |
GWF180(S) | 144 | 180 | 158 | 198 | 6113AZLD/170KW | GPG-160KW | HGM6120 |
GWF200(S) | 160 | 200 | 176 | 220 | TH6126AZLD/240KW | GPG-200KW | HGM6120 |