Product Main

Specifications

Product description
Amorphous alloy is a new type of energy-saving materials, the use of rapid condensation production process, the physical state of the performance of metal atoms were disorderly amorphous arrangement. It is completely different from the crystal structure of silicon steel, more conducive to magnetization and demagnetization. the thickness of its core film is very thin, only 0.025mm, less than 1/10 of the commonly used silicon steel. the transformer with amorphous alloy as iron core is a new energy-saving product with high saturation magnetic induction, low loss, low excitation current, good temperature stability and so on. Core with single or three-phase five-column core. Core clamping sheet or forming frame structure. High and low voltage coil for the rectangular structure. Amorphous alloy transformer no-load loss is low, anti-short-circuit ability, advanced structure, energy saving, environmental protection obvious advantages, in line with our government's 'conservation of resources, protect the environment, building a conservation-oriented society' industrial policy. Is the current energy-saving effect of the ideal distribution transformer. I introduced the company's amorphous alloy distribution transformers have been widely used in factories, mines, parks, residential, stations, terminals and other places, is the old generation of transformers ideal replacement products.

Model Description
S B H 15- □ / □
│ │ │ │ | └──── High Voltage Coil Voltage Rating (KV)
│ │ │ │ └───── Rated capacity (KVA)
│ │ │ └ ─ ─ ─ ─ ─ ─ performance level code
│ │ └ ─ ─ ─ ─ ─ ─ ─ ─ non-gold alloy core
│ └ ─ ─ ─ ─ ─ ─ ─ ─ low-voltage foil-type coil
└ ─ ─ ─ ─ ─ ─ ─ ─ ─ three-phase oil dip
 

Use environmental conditions
 
1, altitude is not 1000m (when more than 1000m need special design).

2, the ambient temperature: the maximum temperature +40 ℃, the hottest month average temperature +30 ℃; minimum temperature -25 ℃, the hottest annual average temperature +20 ℃.

3, the power supply voltage waveform similar to the sine wave; three-phase power supply voltage is roughly symmetrical.

4, installed in the indoor, the use of the environment without obvious pollution.

 
S (B) H15-M-1600/10 amorphous alloy transformer transformer and SBH15-M series dry-type transformers Technical parameters:
 
Model
Rated capacity (KVA)
Join group label
Voltage combination (KV)
No-load loss (W)
Load loss (W)
No-load current(%)
Short-circuit resistance (%)
High pressure
Tapping range
Low pressure
SH15-M-30
30
Dyn11
6
6.3
10
10.5
11
± 5%
or
± 2 × 2.5%
 
0.4
33
600
1.7
4.0
SH15-M-50
50
43
870
1.3
SH15-M-63
63
50
1040
1.2
SH15-M-80
80
60
1250
1.1
SH15-M-100
100
75
1500
1.0
SH15-M-125
125
85
1800
0.9
SH15-M-160
160
100
2200
0.7
SH15-M-200
200
120
2600
0.7
SH15-M-250
250
140
3050
0.7
SH15-M-315
315
170
3650
0.5
SH15-M-400
400
200
4300
0.5
SH15-M-500
500
240
5150
0.5
SH15-M-630
630
320
6200
0.3
4.5
SH15-M-800
800
380
7500
0.3
Sh15-M-1000
1000
450
10300
0.3
SH15-M-1250
1250
530
12000
0.2
SH15-M-1600
1600
630
14500
0.2
SH15-M-2000
2000
750
17400
0.2
5.0
SH15-M-2500
2500
900
20200
0.2
 
Features
1. Transformer core made of amorphous alloy strip rolling, no-load loss than the S9-type transformer reduced by 75%, no-load current decreased by about 80%.
2. Transformer low voltage copper foil coil, with strong anti-burst short circuit capability.
3. Transformer connection group Dyn11, to reduce the impact of harmonics on the power grid to improve the quality of power supply.
4. Transformer box with a fully sealed structure, extended service life, maintenance-free.
5. Transformer vacuum oiling, completely remove the bubbles in the coil to ensure the stability of insulation performance.
6. Each transformer factory before the peak voltage in line with national standards of full-wave lightning impact test to ensure that the transformer is completely reliable transport
S B H15M amorphous alloy transformer