| Usage: | Process Testing Machine |
|---|---|
| Power: | Electronic |
| Brand Name: | Kejie |
| Warranty: | 2 |
| weight: | 70kg |
| Model Number: | 4520B |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
4520B Atomic Absorption Spectrophotometer for Metal Elements in Natural Environment
·Product description
It has excellent optical system, adopted the advanced Multi-core embedded technology to automatically control and digital process for the instrument, and can self-adjust negative high voltage, lamp current, switch spectral bandwidth, control wavelength scanning, so that the repeatability can not only be ensured, and the working efficiency improved.
·Features
1. Excellent optical system
Adopted suspension design, so the shaking and environmental temperature change can not effect the instrument performance.
2. Automatic control to improve the operation efficiency.
3. Good configuration system
It can be optionally installed with hydride generator, quartz enrichment.
·Specification
| Power Supply | AC 220V/50HZ |
| Power | 150W |
| Weight | 70kg |
| Dimensions | 1000mm×350mm×390mm |
| Working Environment Temperature | 15oC-30oC |
| Working Environment Humidity | ≤75% |
| Optical System | |
| Wavelength range | 190nm-900nm |
| Monochromator | C-T |
| Spectral bandwidth | 0.1,0.2,1.0,2.0nm |
| Wavelength Accuracy | Better than ±0.25nm |
| Wavelength repeatability | 0.15nm |
| Baseline draft | 0.004A/30min |
| Detector | Photomultiplier |
| ATomization System | |
| Sensitivity | Quality concentration 3.0μg/ml, absorbance > 0.300Abs |
| LOQ | (Cu)0.006μg/ml |
| Burner | 100mm Metallic titaniumBurner |
| Repeatability | RSD≤1% |
| Sprayer | High-efficiency glass, plastic and stainless steel sprayer |
| Atomizing Chamber | Corrosion-resistant material |
| Location Adjustment | the best height and location of the flame burner can be adjusted, finished flame/hydride changing installation within 1min. |
| Safety Protection | Acetylene gas leakage alarm and turn off system |
| Analysis method | |
| Measurement method | Air-acetylene flame method and hydride generator atomic absorption method. |
| Concentration Calculation | Standard curve, automatic matching, standard addition methods |
| Repeat measurement | 1-20 Times,calculate the average value, and give standard deviation and relative standard deviation. |
| Result Print | Parameters, data results printing |
·Application
It is widely used for the analysis of metal elements in opaque materials for material science, life science, space technology and so on, while it can be used for the detection of trace metal elements in food, medical and natural environments.