Application: | Laser Cutting |
---|---|
Certification: | |
Brand Name: | Zhengye Laser |
Graphic Format Supported: | |
Applicable Material: | |
Laser Type: | Fiber Laser |
Quick Details
Specifications
Usage
the machine is equipped with imported fiber laser, natural granite base, imported linear motor, double workstation, and stationary gantry structure. It is widely used for IT, automobile, LED, jewelry, precision machinery industry, etc.
Feature
1.Security and reliability: High security and reliability of marble base as well as fully enclosed design.
2.High speed and high precision: Adopts imported servo motor, the imported guide rail, stationary gantry structure, imported NC system. the machine has good performance with high cutting speed, smooth corner and high stability.
3.Long using Life: the machine is with long life using the imported fiber laser. High efficiency photoelectric conversion,
4.Good cutting quality: Adopts imported cutting head, small slit width, smooth cutting edge, low heat-affected.
5.High production efficiency: with double work station design, high production efficiency.
6.Convenient Operation: Convenient data processing with dedicated laser cutting software. File formats include DXF, PLT, etc. Interface is simple and friendly, easy operation.
7.CCD can be optional: Auto-finding mark point, work base on the designed graphics and position.
Parametres
Specifications of | |||
Model |
PIL02DL-150F |
PIL02DL-500F |
|
Laser |
Imported Fiber Laser | ||
Laser power |
150W |
500W |
|
Maximum Processing Size |
250mm×250mm | ||
Speed |
≤800mm/s | ||
Accelerated speed |
≤10000 mm/s2 | ||
Positioning accuracy |
±0.003mm | ||
Repetitive positioning accuracy |
±0.001mm | ||
Comprehensive processing precision |
±0.03mm | ||
Smallest linewidth |
0.06mm |
0.08mm |
|
Portable Document Format |
Dxf,plt |
Dxf,plt |
|
Electric Power Supply |
Three-phase Five-wire System,AC380V50Hz/4.5kW |
Three-phase Five-wire System,AC380V50Hz/6.5kW |
|
Dimensions(L x W x H) |
1680mm×1300mm×1500mm | ||
Weight |
1400kg | ||
Environmental Temperature |
10℃-35℃ | ||
Environmental Humidity |
10%-85%RH, non-condensing | ||
Ground Amplitude |
<5μm | ||
Ground Pressure |
60×103kgf/m2 | ||
Control System |
Imported NC System | ||
Optional Function |
CCD automatic positioning |