| After-sales Service Provided: | Engineers available to service machinery overseas |
|---|---|
| Type: | Drying Machine |
| Application: | Liquid |
| Brand Name: | MIC |
| Condition: | room temperature |
| Model Number: | Pilot7-12L |
| Place of Origin: | China (Mainland) |
| Shelf Usable Area: | 0.7 |
| Cold Trap Temperature: | -55 |
| Vacuum Degree: | <7Pa |
| Shelf Temperature: | -40 |
| Shelf Circulation System: | Silicone Oil Circulation System |
| Condenser Capacity: | 12L |
| Drying Capacity: | 7L/24H |
| Shelf Spacing: | 110mm |
| Stopper: | Motor |
| Compressor Power: | 3HP |
Quick Details
Specifications
the following example is for you reference.
1.Brief Introduction:
2.Techincal parameters:
Pilot3-6L
Pilot3-6M
Pilot5-8L
Pilot5-8M
Pilot7-12L
Pilot7-12M
Pilot10-15L
Pilot10-15M
Shelf Usable Area(㎡)
0.3
0.3
0.5
0.5
0.7
0.7
1.0
1.0
Cold Trap
Temperature
(No Loading)
-55℃
-85℃
-55℃
-85℃
-55℃
-85℃
-55℃
-85℃
Vacuum Degree
(No Loading)
<7Pa
Shelf Temperature(No Loading)
-40℃
-55℃
-40℃
-55℃
-40℃
-55℃
-40℃
-55℃
Shelf Circulation System
Silicone Oil Circulation System
Condenser Capacity
6L
6L
8L
8L
12L
12L
15L
15L
Drying Capacity
3L/24H
3L/24H
5L/24H
5L/24H
7L/24H
7L/24H
10L/24H
10L/24H
Shelf Spacing
130mm
130mm
80mm
80mm
110mm
110mm
80mm
80mm
Stopper
Motor
1.5HP
2*1.5HP
2*2HP
3HP
2*3HP
2*3HP
Pump
4L/S
Dimension
(mm)
W760*D1070*H1900
W760*D1070*H1900
W760*D1070*H1900
W760*D1070*H1900
W760*D1300*H1900
W760*D1300*H1900
W760*D1300*H1900
W760*D1300*H1900
3.Performance features:
U Adopt the PLC and HMI
Use the 7 inch touch screen,User-friendly interface,easy to Understand, do not need instructions can also Operte.
U Automatic Programmable Control System
from precfreeze to drying,user-friendly programmable Controls enable you to start runs quickly and the PID controler can control different Ramping and holding segments to meet different temperature protocols.
U Pre-freeze System
Prefreeze so fast and in place pre-freezes sample to save money and time,eliminating the need for a separate freezer and product transfer.
U Defrosting System
Automatically defrosting system is available for cold tray When defrosting is necessary.
U Vacuum Backfilling System
as far as the permanent preservation of the sample Desiccation is concerned it protects a sample by inserting sterile air and Nitrogen gas with back filling system for preventing contamination of the Sample.
U Automatic drainage System
after the drainage and vacuum system interlocking,avoid forget the breakdown of the drain valve in order to produced the Vacuum pump(optional).
U Compressor Delayed Protection