| After-sales Service Provided: | Engineers available to service machinery overseas |
|---|---|
| Type: | Drying Machine |
| Application: | Liquid |
| Brand Name: | MIC |
| Condition: | room temperature |
| Model Number: | Pilot7-12M |
| Shelf Usable Area: | 0.7 |
| Cold Trap Temperature: | -85 |
| Vacuum Degree: | <7Pa |
| Shelf Temperature: | -55 |
| Shelf Circulation System: | Silicone Oil Circulation System |
| Condenser Capacity: | 12L |
| Drying Capacity: | 7L/24H |
| Shelf Spacing: | 110mm |
| Stopper: | Motor |
| Compressor Power: | 2*3HP |
Quick Details
Specifications
the following example is for you reference.
1.Brief Introduction:
2.Techincal parameters: Pilot3-6L Pilot3-6M Pilot5-8L Pilot5-8M Pilot7-12L Pilot7-12M Pilot10-15L Pilot10-15M Shelf Usable Area(㎡) 0.3 0.3 0.5 0.5 0.7 0.7 1.0 1.0 Cold Trap Temperature (No Loading) -55℃ -85℃ -55℃ -85℃ -55℃ -85℃ -55℃ -85℃ Vacuum Degree (No Loading) <7Pa Shelf Temperature(No Loading) -40℃ -55℃ -40℃ -55℃ -40℃ -55℃ -40℃ -55℃ Shelf Circulation System Silicone Oil Circulation System Condenser Capacity 6L 6L 8L 8L 12L 12L 15L 15L Drying Capacity 3L/24H 3L/24H 5L/24H 5L/24H 7L/24H 7L/24H 10L/24H 10L/24H Shelf Spacing 130mm 130mm 80mm 80mm 110mm 110mm 80mm 80mm Stopper Motor 1.5HP 2*1.5HP 2*2HP 3HP 2*3HP 2*3HP Pump 4L/S Dimension (mm) W760*D1070*H1900 W760*D1070*H1900 W760*D1070*H1900 W760*D1070*H1900 W760*D1300*H1900 W760*D1300*H1900 W760*D1300*H1900 W760*D1300*H1900
3.Performance features:
U Adopt the PLC and HMI
Use the 7 inch touch screen,User-friendly interface,easy to Understand, do not need instructions can also Operte.
U Automatic Programmable Control System
from precfreeze to drying,user-friendly programmable Controls enable you to start runs quickly and the PID controler can control different Ramping and holding segments to meet different temperature protocols.
U Pre-freeze System
Prefreeze so fast and in place pre-freezes sample to save money and time,eliminating the need for a separate freezer and product transfer.
U Defrosting System
Automatically defrosting system is available for cold tray When defrosting is necessary.
U Vacuum Backfilling System
as far as the permanent preservation of the sample Desiccation is concerned it protects a sample by inserting sterile air and Nitrogen gas with back filling system for preventing contamination of the Sample.
U Automatic drainage System
after the drainage and vacuum system interlocking,avoid forget the breakdown of the drain valve in order to produced the Vacuum pump(optional).
U Compressor Delayed Protection