Product Main

Quick Details

Brand Name: Koten
Card type: 125Khz
Communication: Dallas TM, Wiegand 26
Dimension: 25*25*22mm
Frequency: 125Khz
Model Number: Z2L
Place of Origin: Russian Federation
Size: the samllest RFID reader in the word

Specifications

GENERAL INFORMATION

Controller is used in access Control systems (ACS). 
It is used to read and transfer ID numbers to the controller 
Key fobs or bracelet with mark 
Standard 
EM-marine 
Via protocol 
Dallas Touch Memory (Ibutton) или Wiegand 26.


 












READER OPERATION


in standby mode, there is a red light. 
at the moment of touch by key fob, the red light will turn off for one second. 
while the card close to the reader, the light indication is disabled. 
If the jumper of light control is cut, there is no red light in standby mode, but there will be the light for one second at the moment of touching by key Fob. 


PURPOSE of PINS

Color - Purpose of wire 



Red - Power Plus from 8 to 18 V. 
Black - power minus, common wire. 
Blue - Data 0 
White - Data 1 / Output Dallas TM, TM centeral. 
Brown - a jumper, to disable the backlight cut. 








DELIVERY SET


Reader - 1. 
Nut - 1 PC 
Packaging - 1 PC.





Round Smallest Z2L RFID Reader 125Khz


the reader is mounted on a flat Surface in place where you can touch the key fob to reader without any problems 
Mark and drill the hole for mounting the reader. 
Insert the reader into the hole and secure it with mounting nut 
Connect the wires to the reader. 
1 - red LED 
2 - retention ring 






SPECIFICATIONS


Operating frequency: 125 kHz 
Type readable cards: EM Marine 
Range of card reading to 2-6 cm 
Protocol for connection to the controller: IButton (Dallas Touch Memory, emulation DS1990A), Wiegand 26 
Maximum length of line from reader to Controller: up to 15m 
Power supply: 8 - 18 VDC 
Current consumption: 35 mA 
Light indication: Red LED 
Housing material: Polyamide 
Size (mm): Diameter 25 mm., Height 22 mm.





OPERATING CONDITIONS STORAGE and TRANSPORT

Converter is designed to Operate in the absence of: 
Atmospheric fallouts, sunshine and humidity Condensation. 
Operating conditions 
Temperature from -30 ° C to +40 ° C; 
Relative humidity less than 98% (at 25 ° C). 
When there are changes in maintenance conditions, The specification of product may differ from the nominal values. 
Storage conditions (group L according to GOST 15150-69) 
Temperature from +5 ° C to +40 ° C; 
Relative humidity less than 80% (at 25 ° C). 
Transportation conditions: 
Temperature from -50° C to +50 ° C; 
Relative humidity less than 98% (at 25 ° C).