Product Main

Quick Details

Rated Power: -
Frequency: -
Speed: -
Output Type: -
Brand Name: Starlight

Specifications

 68GF

 Dat

Set Type: XG-68GF

Standby Power: 68KW/85KVA

Prime Power: 62KW/77KVA

Rated Current: 111(A)

Rated Frequency: 50(Hz)

Start-up time: 56(s)

Power Factor: 0.8(Lag)

Rated Voltage: 400/230(V)

Standard Features

1. Engine: VOLVO TD520GE

2. Radiator 50℃ max

3. Fans are driven by belt, with safety guard

4. 24V charge alternator

5. Dry type air filter, fuel filter, oil filter

6. Alternator: single bearing alternator

7. IP23, insulation class H/H

8. Main line circuit breaker

9. Standard control panel

10. Absorber

11. Muffler

12. User manual

Diesel Engine Data

Manufacturer:

VOLVO

Model:

TD520GE

Standby/Prime Power:

85KW/77.5KW

Rated Speed:

1500(r/min)

Cycle:

4 stroke

Cylinder Arrangement:

4 in line

Displacement:

4.76L

Bore and Stroke:

108*130(mm) 

Compression Ratio:

17.5:1

Governor Type:

Electronic

Start battery voltage:

24V DC

 

 

Air Intake System

Air Intake System:

Turbo

Max Intake Restriction:

3kpa

Burning Capacity:

4.8m3/min

Air Flow:

90m3/min

 

 

Exhaust System

Exhaust Gas Flow:

15.4m3/min

Exhaust Temperature:

610℃ 

Max Back Pressure:

3kPa

 

 

Fuel System

Fuel System:

Directly Injection Fuel System, Bosch Pump

100%( Prime Power) Load:

206g/kwh

50%( Prime Power) Load:

221g/kwh

 

 

Oil System

Total Oil Capacity:

13L

Oil Consumption:

≤0.07L/h 

Engine Oil Tank Capacity:

11L

Oil Pressure at Rated RPM:

400-440kPa

 

 

Cooling System

Cooling Way:

Water-cooled

Total Coolant Capacity:

22L

Thermostat:

83-95℃ 

Max Water Temperature:

110℃ 

 

 

Alternator Data

 

Manufacturer:

STARLIGHT/STAMFORD/SIEMENS/MARATHON/ENGGA /KEPU

Excitation Mode:

Brushless and self- exciting

Number of phase and Access Act:

3-phase 4-wire

Connecting Type:

"Y" type connecting

Alternator Capacity:

85KVA

Alternator Efficiencies:

95

Overload:

(PRP)110% load can run 1h

Protection Level:

IP22-IP23

Insulation Class, Temperature Rise:

H/H

Telephone Influence Factor (TIF):

50

THF:

2%

Voltage Regulation, Steady State:

≤±1%

Air Cooling Flow:

0.216m3/s

Altitude:

≤1000m

 

 

Genset Electrical Performance

 

Voltage Regulation:

≥±5%

Voltage Regulation, Stead State:

≤±1%

Sudden Voltage Warp (100% Sudden Reduce):

≤+25%

Sudden Voltage Warp (Sudden Increase):

≤-20%

Voltage Stable Time (100% Sudden Reduce):

≤6S

Voltage Stable Time (Sudden Increase):

≤6S

Frequency Regulation, Stead State:

≤5%

Frequency Waving:

≤1.5%

Sudden Frequency Warp (100% SuddenReduce):

≤+12%

Sudden Frequency Warp (Sudden Increase):

≤-10%

FrequencyRecoveryTime(100%SuddenReduce):

≤5S

FrequencyRecoveryTime(Sudden Increase):

≤5S

 

Options

Engine

Alternator

Heater 2KW & 4KW

Anti Condensation Heater

Battery Charger 3.5A & 7A

Permanent Magnet Generator(PMG)

Water Separator

Drop CT(for Paralleling)

Daily Fuel Tank

 

Fuel Level Sensor

 

Control System

Others

Remote Control Panel

Rainproof Type

Auto Transfer Switch (ATS)

Soundproof Type

Paralleling System

Trailer Type

Open Type

Overall Size

Weight

2080(mm)*940(mm)*1550(mm)

1290(kg)

 

Soundproof Type

Overall Size

Weight

2800(mm)*1200(mm)*1640(mm)

1850(kg)

volvo Diesel Generator Set 68GF