Temperature range: | -60C~150C |
---|---|
Accuracy: | +0.5,-0.5/+2.0,-2.0 |
Theory: | Temperature Recorder |
Usage: | Industrial |
Brand Name: | OTS JUNYUAN |
Model Number: | JY-OTS-225B12 |
Place of Origin: | Chile |
Application: | Industry, School, Hosipital, Lab |
Certification: | CE, ISO, SGS, RoHS |
Controller: | Programmable LCD Touch Screen |
Loading Method: | Static Load |
Quick Details
Specifications
IEC68-2-03 Standard Double Duty Thermal Shock Chambers
Applicable Industries:
Programmable High Low Temperature Shock Impact Test Equipment used to test the material structure or composite Material in an instant by the extremely high temperatures and very low Temperature continuous environment which can endure the degree of order In the shortest possible time to test its thermal expansion and Contraction caused by chemical changes physical harm.
the applicable the object material, including metals, plastics, rubber, electronic, ..., etc., can be used as the basis of its product improvement or reference.
Inner size selection
Detail Specification
Our services:
1.on-site maintenance and repair
2.Warranty support
3.over-the-phone service support and advice
4.If you have an OTS temperature humidity chamber, we will do our best to help you in whatever way we can.
5.Manuals: PDF files of manuals for current models are available free. Please Contact us to request a copy. Older and printed copies at additional Charge.
6.Service repair: We prefer you contact us direct at the Factory with any problems you may be experiencing. We help diagnose the Problem, arrange for any needed parts, and schedule a technician to do the repairs. Rarely can a local contractor get all that done for you as Quickly as we can. We also guarantee the work done.
FAQ:
Q1: Can you customize the product?
A: Yes, we can customize any products according to requirements.
Q2: how to choose the most suitable products?
A: Our professional team will give you the best suggestion,just be patiently to tell us the information about the parameters your Required.
Q3: Can you arrange installations and commissioning in our lab?
A: Firstly, for standard chamber we had 3-5 days commissioning Before shipping, you just need link power in your lab, then can start to operate
Secondly; we had detailed operation manual with chamber, any problems you can find and solve in it
Thirdly, some of customized chambers we should to install and teach your team to operate.
If you want to know more information...
Please leave a message below and click " SEND "
Thanks for your time and attention~Thank you!
Applicable Industries:
Programmable High Low Temperature Shock Impact Test Equipment used to test the material structure or composite Material in an instant by the extremely high temperatures and very low Temperature continuous environment which can endure the degree of order In the shortest possible time to test its thermal expansion and Contraction caused by chemical changes physical harm.
the applicable the object material, including metals, plastics, rubber, electronic, ..., etc., can be used as the basis of its product improvement or reference.
Purpose: |
Thermal
Shock test chamber makes it possible to quickly and autonomously
Transfer test items back and forth repeatedly between a hot and cold
Environment. Thermal shock testing is different from thermal cycling,
The latter being a longer and slower process. To see a more in depth
Look at thermal shock versus thermal cycling. |
Inner size selection
Model |
JY-OTS-50 | JY-OTS-80 | JY-OTS-150 | JY-OTS-225 | JY-OTS-408 |
Inner size WxHxD(cm) | 364035 | 405040 | 506050 | 607550 | 808560 |
External size WxHxD(cm) | 138x180x155 | 150X190X160 | 190x200X195 | 210x220X205 | 225x250x220 |
Detail Specification
Shock Temperature ragne |
-65C~150C | ||||
Heating up time | RT~200C about 35min | ||||
Cooling down time | RT~-70C about 90min | ||||
Temp recover time/change time | 5min / 10sec | ||||
Temp control accuracy/ | 0.5C / 2.0C | ||||
Distribution accuracy | |||||
Inner materials | SUS 304# stainless steel plate for inner chamber,and stainless steel plate | ||||
+ spray painting for external chamber. | |||||
Insulation materials | High-temperature high-density amino acid ethyl ester foam insulator material. | ||||
Systems | P.I.D+S.S.R+Microcomputer balanced temperature control system. | ||||
Cooling systems | Semi-hermetic two-stage compressor (water-cooled) / | ||||
Hermetic two-stage compressor (air-cooled). | |||||
Safety devices | Fuse switch, high and low pressure protection switch compressors, | ||||
Refrigerant pressure protection switch failure warning system, electronic siren. | |||||
Fitting | Outlook window (special purchase), the upper and lower adjustable | ||||
Compartment two energized measured line hole, casters,level bracket. | |||||
Power | 3 phase AC380V 50HZ/60HZ | ||||
Controller | Tanwan TATO or TH900C | ||||
Compressor | Germany Bitzer Brand |
Our services:
1.on-site maintenance and repair
2.Warranty support
3.over-the-phone service support and advice
4.If you have an OTS temperature humidity chamber, we will do our best to help you in whatever way we can.
5.Manuals: PDF files of manuals for current models are available free. Please Contact us to request a copy. Older and printed copies at additional Charge.
6.Service repair: We prefer you contact us direct at the Factory with any problems you may be experiencing. We help diagnose the Problem, arrange for any needed parts, and schedule a technician to do the repairs. Rarely can a local contractor get all that done for you as Quickly as we can. We also guarantee the work done.
FAQ:
Q1: Can you customize the product?
A: Yes, we can customize any products according to requirements.
Q2: how to choose the most suitable products?
A: Our professional team will give you the best suggestion,just be patiently to tell us the information about the parameters your Required.
Q3: Can you arrange installations and commissioning in our lab?
A: Firstly, for standard chamber we had 3-5 days commissioning Before shipping, you just need link power in your lab, then can start to operate
Secondly; we had detailed operation manual with chamber, any problems you can find and solve in it
Thirdly, some of customized chambers we should to install and teach your team to operate.
If you want to know more information...
Please leave a message below and click " SEND "
Thanks for your time and attention~Thank you!