Application: | Lighting Controller,Thermal Controller,Solar System Controller,Charger Controller,Solar Working Station,Voltage Controller |
---|---|
Model Number: | CM6024 |
is_customized: | Yes |
Brand Name: | Y-SOLAR |
Maximum Current: | 60A |
Rated Voltage: | 12V 24V AUTO |
Max input Voltage: | 48v |
Max Power: | 1440W,24V;720W,12V |
Battery Type: | Lead-acid,GEL,Flooded |
Charge Mode: | PWM |
Display: | LCD display |
Control Mode: | Light and timer Control |
Item : | Solar Charge Controller 60A |
Unit Type: | piece |
Package Size: | 10cm x 8cm x 5cm (3.94in x 3.15in x 1.97in) |
Package Weight: | 0.8kg (1.76lb.) |
Quick Details
Specifications
PWM 60A 12V 24V Solar Regulator with LCD Solar Charge Controller for Lead-acid GEL Flooded Battery Solar CM6024Z Voltage Control
Overall:
CM series controller is a kind of intelligent, multi-purpose solar charge and discharge controller. The family use the fixed LCD display, with a very friendly interface; various control parameters can be flexibly set, fully meet your various application requirements. CM series controller has following features:
1pcs temp sensors
1pcs user manuals(English)
Installation:
1. Ready tools and cables. Encourage you to matching the right cables. Ensure that the current density<4mm2 that is conductive to reducing the line voltage drop. Recommended: 60A with 20mm2 cable. Check weather the installation sitescompliance with the relevant safety requirements. Please avoid the damp, dusty, there is a place flammable, explosive and corrosive gases use the controller to install.
2. Install the controller into a fixed vertical plane. See section 5 of the pore size and pore spacing. In order to ensure a good thermal control conditions, please set aside each 10cm below the controller space.
3. As shown on the right, connect the (1) Load, (2) Battery and (3) Solar Panel to the controller according to the order of (1) (2) (3). Pay attention to the load, battery, solar panel and controller of same polarity.
4. Put into the external temperature sensor on the left of the controller (probe port). The temperature sensor should be similar space with battery. (Otherwise, the controller will control the parameters of all wrong temperature compensation.)
5.If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the controller (communication port), the other end to connect to The host computer.
Demolition: To prevent accidents, please order the demolition of solar panels, battery and load disconnect with controller.
Note:Battery polarity will not damage the controller, but you will have a load equipment security risks.
Model | CM6024Z | CM6048 |
Rated Current | 60A | |
Rated Voltage | 12V/24V | 48V |
Maximum Voltage of solar panel | 50V | 100V |
Float Voltage | 13.7V/27.4V | 54.8V |
Low Voltage Disconnection | 10.7V/21.4V | 42.8V |
Low Voltage Reconnection | 12.6V/25.2V | 50.4V |
No load loss | <30mA | |
loop voltage drop | <200mV | |
Charging Mode | PMW Mode | |
Temperature Compensation | -4mV/Cell/Degree | |
Notes | Model suffix ?Z? represent automatic identify system voltage level,?T? represent controller with remote monitoring |
Picture: