Product Main

Quick Details

is_customized: Yes
Maximum Current: 41.7A/83.3A
Model Number: 1000W60
Application: Wind Solar Hybrid Controller
Rated Voltage: 12/24V Auto
Wind Power: 600W
Max Current: 41.7A/83.3A
Commodity: MPPT Wind Solar Hybrid Charge Controller
Charge Control Mode: Charge Control Mode: Wind: MPPT Boost Charge, Stepless Unloading, PWM charge for Solar
Discharge Control Mode: Light Controll Mode, Time Controll Mode and etc.
Protection Function: lightning, reverse connect, over charge/discharge, open-circuit..
Display: Big Size LCD Display
Show parameters: voltage,charge current,battery volumetric
Unit Type: piece
Package Size: 26cm x 22cm x 20cm (10.24in x 8.66in x 7.87in)
Package Weight: 2.7kg (5.95lb.)

Specifications

1000w 12/24V 600W wind+400W solar MPPT hybrid Solar  Wind Controller with 3 years warranty LCD Display free dump load7

1100w Auto 12/24V Off Grid Intelligent MPPT Wind Solar Hybrid Charge Controller with 3 years warranty / LCD display

Product overview

The controller is designed specifically for hybrid wind solar street light systemwhich can make the wind solar hybrid street light system of various resources to achieve the best configuration, of course, the controller with some simple Settings can also be used in household system.

 

Intelligent design succinct structure,powerfulcontroll, stable performance, safety and reliability of the products.Choose MPPT Wind turbine charging ways, charging more efficiency than ordinary PWM way more superior. The boost charge function, solve the low charging efficiency problem of low wind speed (optional). Professional digital intelligent control.

   

 

Features:

1.The Wind turbine charging part and Solar charging part are independent of each other, can make Wind turbine controller or solar controller using independent (As a Wind turbine controller cannot use light control function).

  • Wind turbine charging adopted booster MPPT technology, which makes under low wind speed, the Wind turbine's electricity can still be used;
  • In the high wind speed or the Wind turbine of power is beyond the scope of the battery and load absorption, the controller immediately launched the stepless unloading function,protection system of the equipment.
  • Solar charging using in serieMOS tube PWM technology, which makes the controller power consumption is small, the system more stable.

2.Discharge part working mode can be set, light control mode, time control function etc, The user can be set up according to the requirements on its own combination.

3.Manmachine interface of the controller USES a custom LCD screen and four key operation mode, the user to use simple and easy to use, popular and easy to understand, convenient and quick. 

4. The controllers with perfect protection function, including: lightning counter-attack, solar charger, over-voltage automatic braking, storage battery reverse connect and open protection, etc.

Parameters

 

 

model 1000W50 1000W60 1100W60 1200W60 1400W80
Rated voltage 12V/24V Automatic identification system voltage
PV input power 500W 600W 500W 600W 600W
Wind turbine power 500W 400W 600W 600W 800W
charging charging 41.7A/83.3A 41.7A/83.3A 45.8A/91.6A 50A/100A 58.3A/116.6A
Even charge protection 14.4V +/- 1%(12V)
floating Charge 13.8V +/- 1%(12V)
Even charge recover 13.2V +/- 1%(12V)
Temperature Compensation -24mV/
Over Discharge Shut off (DC) 10.8V +/- 1%(12V)
Resume (DC) 12.3V +/- 1%(12V)
Over Voltage Shut off (DC) 16V±1%(12V)
Resume (DC) 15V±1%(12V)
No-load Current   ≤0.1A
Voltage drop (DC) ≤0.5V
Control mode Wind turbine MPPT charge function, PWM uninstall function, PWM over-current limiting
Boost charge Flexible independent step-up circuit (optional)
Display LCD
Show parameters voltagecharge current,battery volumetric
Protected type Lightning protection, solar cells, anti-anti-charge protection, battery open-circuit protection, battery reversal protection, over speed and over-voltage soft automatic brake protection, overload protection.
Heat emanation way radiator
Working Temperature -25~+55
Height ≤5500m(2000m above the need to reduce power use)
Environment humidity 0~90%,No condensation
Warranty 3 years
Weight 1. Net Weight: 1.20KG        2. Gross Weight: 2.7 KGS/PC(controller+dump load)
Size(L*W*H) 1. 162×140×64(MM)                                                    2. Packing Size: 26X22X20CM

 

Technical note:

In offgrid system, there is always a pair of contradictions that produce energy source and energy absorption of load does not match the problem, may be the following situation: 1. The power supply can be issued under the condition of sufficient electrical energy of the load is not likely to work and the battery power is full, so this time we need to send power electricity do discharge processing, otherwise may cause permanent damage to the equipment;2. In the power supply does not have enough electric power support is likely to appear when battery power is rarely lead to load can not have normal work, so we also need to improve power generation capacity in this situation.

 

In our wind solar system, solar panels power relative to the Wind turbine power is very stable power supply, so we had a wind solar hybrid controller mainly for Wind turbine design the booster MPPT charging technology and step-less unloading function, and in view of the solar panels still take simple and efficient PWM charging technology.

 

Booster MPPT mainly for most of the time in many parts of the wind power is not enough to support a generator to the condition of the battery charging, specific working principle is: the Wind turbine under the condition of wind speed reach the rated wind speed, the resulting voltage and power are not reach the rated power, we through realtime acquisition Wind turbine by means of booster circuit of voltage and current from the boost voltage to the battery voltage to the system requirements, using the software MPPT algorithm make the Wind turbine of power use as much as possible.

  

Stepless unloading function mainly aimed at the first case, when don't need additional energy, will generate the energy consumption of the Wind turbine on unloading device, the controller dedicated connection port of unloading device, the user can be selected according to actual condition when the choose and buy, we suggest in good wind conditions, such as coastal and western is empty,you must configure unloading;In some inland areas where wind conditions in general, we also recommend that try to configure unloading.

Product Photos

 

hybrid wind solar controller

 

hybrid wind solar controller5hybrid wind solar controller6

 

 

 

3

hybrid wind solar controller7

HYBRID WIND SOLAR CONTROLLER.jpgWind product.jpg

Dimension

 

OperatingInstruction

HTB1wzpYHXXXXXbrXpXXq6xXFXXXm

 

Status Indication

Button instructions

 

Button1:Press this button to enter setup interface or switch set up program;

Button2:Click this button to switch down in page views,in the setup interface click this button is used to reduce the parameter values, step 0.1 V.

Button3:Click this button to switch up browsing on page views,in the setup interface click this button is used to increase the parameter value, step 0.1 V.

Button4:Click this button to exit the setup interface, and save the parameters.

 

 

LCD screen (the default interface)

To the user in accordance with the specifications, general automatically entered into the following interface 

Parameters to browse

User press down key to view the Wind turbine charging current "IWind turbine",the solar charging current"Ipv", press the up button to return to the interface of a parameter.

 

The above three pages, collectively known as browse pages, when a minute don't operating controller buttons, LCD back-light will automatically go out.after pressing any key will once again lit back-light and continuously for one minute.

Parameter Settings

Press Enter key,the controller into the parameter set interface, as shown infollowedpic,Vfloat” represent this time can be set to float charging voltage value, the user can press or key numerical,each time you press the increase or decrease 1v,set up finished,the user can press the ESC key to exit to browse the first page, can also continue to press Enter to switch to the next project, operation method as above.

Use environment 
1. Should be in a clean dry ventilated environment. 
2. Avoid direct sunlight and the sun, rain, humid mist of the environment. 
3. To avoid dust in a soil, dust in the environment. 
4. The battery should be placed away from 0.5m or more. 
5. Is strictly prohibited in flamable, explosive gas environments, to guard against flames and sparks! 
6. Ambient temperature -25 degree  - +50 degree . 
7. The air relative humidity less than 85% (25 degree ± 5 degree ). 

 

Safety and protection
The controller has the solar energy the counter-attack, reverse connect battery, battery open circuit, lightning protection, wind speed and over voltage protection function.
Note: lightning protection refers to the last level of protection, equipment necessary for lightning prone areas, need to use special multistage lightning protection system of lightning protection device, etc.If the user has this requirement, it is necessary to increase the corresponding cost of distribution system and indicate when you order it.

 

After-sales service

We provided product to the warranty period of one year since it is sold. If the product is exceed warranty or damaged by transportation, improper use, human element, force majeure, it is not under warranty.

Statement: we reserve the right to change products, product updates without prior notice

 

Any question, please feel free to contact with me: