Product Main

Quick Details

is_customized: Yes
Application: Charger Controller
Maximum Current: 80A
Brand Name: Y-SOLAR
Model Number: 80i
Rated Voltage: 12V 24V
Work for: off grid pv system
Maximum Voltage of solar panel: 50V
Max Power: 1000W(12V) 2000W(24V)
Charging Mode: PMW Mode
Amps: 80A
Installtion cable area: 3# AWG ( 25mm2 )
Float Voltage: 13.7V/27.4V
Low Voltage Disconnection: 10.7V/21.4V
Low Voltage Reconnection: 12.6V/25.2V
Unit Type: lot (5 pieces/lot)
Package Size: 20cm x 10cm x 5cm (7.87in x 3.94in x 1.97in)
Package Weight: 4.0kg (8.82lb.)

Specifications

5PCS/LOT Wholesale 80A Solar Charge Controller 12V 24V 1000W 2000W Solar Panel LCD PWM Charging for Off Grid PV Solar System

 

 

Package Included:
1. 5X solar controller 80A
2. 5X Users` Manual
3. 5X Temp. Sensor

80I controllers are a kind of intelligent, multi-purpose solar charge and discharge controller. The family use the fixed LCD display, with a very friendly interface; various control parameters can be flexibly set, fully meet your various application requirements.

Features:

 
Simple button operation
 
Intelligent PWM charge mode
 
Adjustable charge-discharge control parameters
 
Overload, Short Circuit Protection
 
Battery reverse-discharge protection
 
Battery reverse connection protection
 
Image of LCD graphic symbol
 
Automatic Identification System Voltage level
 
Automatic Temperature Compensation
 
Settable Operating mode of Load
 
Remote monitoring and control function (custom)
 
Battery Low Voltage Disconnection (LVD)
 
Accumulated function of charge and discharge Ampere hours
Model
60I
80I
Rated Current
60A
80A
Rated Voltage 12V/24V
Maximum Voltage of solar panel 50V
Float Voltage 13.7V/27.4V
Low Voltage Disconnection 10.7V/21.4V
Low Voltage Reconnection 12.6V/25.2V
No load loss <30mA
loop voltage drop <200mV
Charging Mode PMW Mode
Temperature Compensation -4mV/Cell °C

 

Installation
 
1 Get ready for tools and cables. Advising you to matching the right cables. Ensure that the current density<4A/mm2 that is conductive to reducing the line voltage drop. Recommendation: 30A with 10mm2 cables. Check whether the installation sites compliance with the relevant safety requirements. Please avoid the damp, dusty, there is a place flammable, explosive and corrosive gases use the controller to install. 
 
2 Install the controller into a fixed vertical plane. See section 5 of the pore size and pore spacing. In order to ensure a good thermal control conditions, please set aside each 10cm below the controller space.
 
3 As shown on the right, connect the (1) Load, (2) Battery and (3) Solar Panel to the controller according to the order of (1) (2) (3). Pay attention to the load, battery, solar panel and controller of same polarity.
 
4 Put the external temperature sensor into the left of the controller (probe port). The temperature sensor should be placed at the similar space of the battery. (Otherwise, the controller will control the parameters of all wrong temperature compensation.)
 
5 If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the controller (communication port), the other end to connect to the host computer.
 
Demolition: To prevent accidents, please order the demolition of solar panels, battery and load disconnect with controller.
Note Battery polarity will not damage the controller, but you will have a load equipment security risks.
 

Installtion cable area

>3# AWG ( 25mm2 )

Operation temperature

-20 °C ~ 50 °C

storage temperature

-30 °C~ 70 °C

Humidity requirement

<90% , no condensation

Size

130mm*188mm*62mm

Mounting hole spacing

90 mm 178 mm -- 5

Weight

700g

 

 

 

60I (2)60I (3)60I (4)60I (5)60I (7)60I (8)60I (9)60I (10)