is_customized: | Yes |
---|---|
Maximum Current: | 80A |
Model Number: | 5kw |
Application: | wind and solar |
Rated Voltage: | 96V |
Unit Type: | piece |
Package Size: | 60cm x 40cm x 30cm (23.62in x 15.75in x 11.81in) |
Package Weight: | 22.0kg (48.50lb.) |
Quick Details
Specifications
Product features
- Series controller
- Voltage regulation
- Automatic detection of voltage
- PWM control
- Multistage charging technology
- Current compensated load disconnection
- Automatic load reconnection
- Temperature compensation
Electronic protection functions
- Overcharge protection
- Deep discharge protection
- Reverse polarity protection of load, module and battery
- Automatic electronic fuse
- Short circuit protection of load and module
- Overvoltage protection at module input
- Open circuit protection without battery
- Reverse current protection at night
- Wind-turbine auto brake and brake switch for manual operation
- Battery overvoltage shutdow
<table align="left" border="1" cellpadding="0" cellspacing="0" style="margin: 0px; padding: 0px; font-family: Arial, Helvetica, sans-senif, SimSun, <span class=" ksp-highlight"="">
Model No. |
SSWC-50-48 |
SSWC-50-96 |
SSWC-50-120 |
SSWC-50-240 |
Wind turbine power |
5000 W |
|||
Solar rated power |
1500 W |
|||
Rated Battery Voltage |
48 V |
96 V |
120 V |
240 V |
Wind-turbine input power max. |
9000 W |
|||
Wind-turbine input current max. |
200 A |
100 A |
80 A |
50 A |
Over-charge voltage |
58.8 V |
116 V |
144 V |
264 V |
Over-charge recovery voltage |
56 V |
110 V |
138 V |
288 V |
Method of control |
Two way control with PWM |
|||
Free-load lost power |
≤6 mA |
|||
Voltage lost on charging |
≤0.26V |
|||
Voltage lost on discharge |
≤0.15V |
|||
Display |
* LCD show battery charging current; battery voltage; system operation status * LED show battery situation ;device working status |
|||
Protection Mode |
Solar cells reverse charging, solar cells anti-reverse connection, battery over-charging, battery over-discharge, battery anti-reverse connection, over-load, Load anti-reverse connection, wind-turbine current limited, wind-turbine rotation limited, manual brake switch equipped. |
|||
Over-load and short-circuit protection |
1.25times 60sec./ 1.5times 5sec. action |
|||
ambient temperature |
-25°C - +55°C |
|||
humidity |
<85% RH without condensation |
|||
Dimension of main-device |
415mm x 345mm x 160mm |
|||
Dimension of Dump-load Box |
710mm X 410mm X 440mm |
|||
Weight of main-device |
17 Kg |
|||
Weight of Dump-load Box |
15 kg |
|||
Cooling Method |
Cooling Fan |