Model Number: | S30I |
---|---|
Maximum Current: | 30A |
is_customized: | Yes |
Brand Name: | Y-SOLAR |
Application: | Charger Controller |
Rated Voltage: | 12V/24V |
Application: | for renewable energy systems |
Maximum Current: | 30A |
Nominal System Voltage: | 12 / 24VDC Auto work |
Battery Type: | Gel,Sealed,Flooded |
Charge Mode: | PWM Charge mode |
Load Control mode: | Light and timer control |
Enclosure: | IP30 |
Float charging voltage: | 13.8V(12Vsystem) 27.6V(24Vsystem) |
reconnect voltage: | 12.2V(12Vsystem) 24.4V(24Vsystem) |
disconnect voltage: | 11.1V(12Vsystem) 22.2V(24Vsystem) |
Unit Type: | piece |
Package Size: | 20cm x 20cm x 20cm (7.87in x 7.87in x 7.87in) |
Package Weight: | 0.2kg (0.44lb.) |
Quick Details
Specifications
30A Solar Charge Controller Stable Quality CE Certificated Comfortable Protect Battery for Renewable Energy Systems Solar S30Icharge controllers
solar panel charge contr
The controller is for off-grid solar system,especially in solar lighting system and protects the battery from being over charged by the solar module and over dischargerged by the loads.The charging process has been optimized for long battery life and improved system performance
Three battery type option:
0 | [Load work mode] |
b1 | [Battery type] |
J0 | Load start-up delay |
S5 | Optical sensitivity |
F0 | Float charging voltage |
H0 | Low voltage reconnect voltage |
q0 | Low voltage disconnect voltage |
8.8. | Restore factory Settings |
When you want to change`s setting indicator is on, press the setting button for more than 5 seconds till the LED digital tube flashes. Then press the setting button till the desired number appears according to the following table. The setting is finished when the digital tube stop flashing.
Load work mode ,0] Table 4-6
Describe |
LED digital No. |
Dusk to Dawn, Load will be on all night |
0 |
Load will be on for 1 hour after ten minutes delay since sunset |
1 |
Load will be on for 2 hour after ten minutes delay since sunset |
2 |
Load will be on for 3 hour after ten minutes delay since sunset |
3 |
Load will be on for 4 hour after ten minutes delay since sunset |
4 |
Load will be on for 5 hour after ten minutes delay since sunset |
5 |
Load will be on for 6 hour after ten minutes delay since sunset |
6 |
Load will be on for 7 hour after ten minutes delay since sunset |
7 |
Load will be on for 8 hour after ten minutes delay since sunset |
8 |
Load will be on for 9 hour after ten minutes delay since sunset |
9 |
Load will be on for 10 hour after ten minutes delay since sunset |
10 |
Load will be on for 11 hour after ten minutes delay since sunset |
11 |
Load will be on for 12 hour after ten minutes delay since sunset |
12 |
Load will be on for 13 hour after ten minutes delay since sunset |
13 |
Load will be on for 14 hour after ten minutes delay since sunset |
14 |
Load will be on for 15 hour after ten minutes delay since sunset |
15 |
ON/OFF mode |
16 |
TEXT mode |
17 |
Data Sheet:
Description |
Parameter |
Nominal System Voltage |
12 / 24VDC Auto work |
Battery Voltage Range |
6-36V |
Rated Battery Current |
10A,20A,30A |
Charge Circuit Voltage Drop |
≤0.26V |
Discharge Circuit Voltage Drop |
≤0.15V |
Self-consumption |
≤6mA |
Threshold Voltage Parameters
Description |
Parameter |
NTTV (Night Time Threshold Voltage) |
5V; x2/24V |
DTTV (Day Time Threshold Voltage) |
6V; x2/24V |
Temperature Compensation Coefficient
Description |
Parameter |
Temperature Compensation (TEMPCO)* |
-25mV/ °C /12V[25 °C ref] |
* Compensation of equalize, boost, float and boost reconnect voltage
Battery Voltage Parameters (temperature at 25 °C )
Charging setting |
Sealed |
Flooded |
Gel |
Over voltage disconnect |
15.5V;x2/24V
|
||
Charging limit voltage |
15.0V;x2/24V
|
||
Equalize charging voltage |
14.6V;×2/24V |
14.8V;×2/24V |
14.4V;×2/24V |
Boost charging voltage |
14.4V;×2/24V |
14.6V;×2/24V |
14.2V;×2/24V |
Float charging voltage |
13.8V;x2/24V
|
||
Boost reconnect charging voltage |
13.2V;x2/24V
|
||
Low Voltage reconnect voltage |
12.6V;x2/24V
|
||
Under Voltage warning reconnect voltage |
12.2V;x2/24V
|
||
Unver voltage warning voltage |
12V;x2/24V
|
||
Low voltage disconnect voltage |
11.1V;x2/24V
|
||
Discharge limit voltage |
10.8V;x2/24V
|
||
Equalize duration |
60min
|
||
Boost duration |
60min
|
Environmental parameters
Environmental parameters |
Parameter |
Working temperature |
35 °C to +55 °C |
Storage temperature |
-35 °C to +55 °C |
Humidity |
10%-90% NC |
---|---|
Enclosure |