is_customized: | Yes |
---|---|
Application: | Charger Controller |
Maximum Current: | 25 |
Model Number: | 12V/24V/48V-25A |
Rated Voltage: | 12V 24V 48V auto work |
Unit Type: | piece |
Package Size: | 27cm x 20cm x 12cm (10.63in x 7.87in x 4.72in) |
Package Weight: | 2.5kg (5.51lb.) |
Quick Details
Specifications
MPPT solar controller modes | 15A | 20A | 25A | 30A | 40A | ||
Charge mode | MPPTmaximum power point tracking | ||||||
Charge method | Three stages: constant current(MPPT),constant voltage,floating charge | ||||||
System type | DC12V/24V/48V | Automatic recognition | |||||
System voltage | 12V system | DC9V~DC15V | |||||
24V system | DC18V~DC30V | ||||||
48V system | DC36V~DC60V | ||||||
Soft start time | 12V/24V/48V system | ≤3S | |||||
Dynamic response recovery and range | 12V/24V/48V system | 500us | |||||
MPPT efficiency | 12V/24V/48V system | ≥96.5%,≤99% | |||||
INPUT CHARACTERISTICS | |||||||
MPPT working voltage and Range | 12V system | DC14V~DC100V | |||||
24V system | DC30~DC100V | ||||||
48V system | DC60~DC100V | ||||||
Low voltage input Protection point | 12V system | DC14V | |||||
24V system | DC30V | ||||||
48V system | DC60V | ||||||
Low voltage input Recovery point | 12V system | DC18V | |||||
24V system | DC34V | ||||||
48V system | DC65V | ||||||
Input over voltage protection point | 12V/24V/48V system | DC110 | |||||
Input over voltage recovery point | 12V/24V/48V system | DC100V | |||||
Maximum PV power | 12V system (W) | 213 | 284 | 355 | 426 | 568 | |
24V system (W) | 426 | 568 | 710 | 852 | 1136 | ||
48V system (W) | 852 | 1136 | 1420 | 1704 | 2272 | ||
CHARGE CHRECTRESTICS | |||||||
Selectable Battery Types (Default type is GEL battery) | 12V/24V/48V system | Sealed lead acid, vented, Gel, NiCd battery (Other types of the batteries also can be defined) | |||||
Constant Voltage | 12V/24V/48V system | Please check the charge voltage according to the battery type form. | |||||
Floating Charge Voltage | 12V/24V/48V system |
| |||||
Rated Input Current | 12V/24V/48V system | 15A | 20A | 25A | 30A | 40A | |
Current-limiting Protection | 12V/24V/48V system | 20A | 25A | 30A | 35A | 45A | |
Temperature Factor | 12V/24V/48V system | ±0.02%/ | |||||
Temperature Compensation | 12V/24V/48V system | 14.2V-(The highest temperature-25°C )*0.3 | |||||
Output Ripples(peak) | 12V/24V/48V system | 200mV | |||||
Output Voltage Stability Precision | 12V/24V/48V system | ≤±1.5% | |||||
Output Discharge Characteristics | |||||||
Output voltage | Base on battery voltage | ||||||
Low voltage output Protection point | Default 10.5V; recovery 11V; custom available ; | ||||||
Rated output Current | 30A | ||||||
The output control | Always on, always off, PV voltage control switch | ||||||
Output control set mode | Controller button or upper computer | ||||||
Display | |||||||
LED digital tube display | Battery voltage, charge current | ||||||
LED light display | Charging indicator light, LOAD indicator light | ||||||
PC communication port | RS232 | ||||||
Protection | |||||||
Input Low Voltage Protection | Check the input characteristics | ||||||
Input Overvoltage Protection | Check the input characteristics | ||||||
Charge over voltage power Protection | yes | ||||||
Low Voltage output Protection | yes | ||||||
Rated output Current protection | yes | ||||||
Temperature Protection | yes | ||||||
Other Parameters | |||||||
Noise | ≤40dB | ||||||
Thermal heat-dissipating method | Itself cooling | fan cooling | |||||
Components | Imported material, with EU standards. | ||||||
Certification | CE\FCC\ROHS | ||||||
Physical | |||||||
Measurement D x W x H(mm) | 205*168*60 | ||||||
package size D x W x H(mm) | 265*196*110 | ||||||
N.G(KG) | 1.8kg | ||||||
G.N(KG) | 2kg | ||||||
Type of Mechanical Protection | IP25 | ||||||
Environment | |||||||
Humidity | 0~90%RH ( no condense) | ||||||
Altitude | 0~3000m | ||||||
Operating Temperature | -20°C ~ +50°C | ||||||
Storage Temperature | -40°C ~ +75°C | ||||||
Atmospheric Pressure | 70~106kPa |