Product Main

Quick Details

is_customized: Yes
Application: Solar System Controller
Maximum Current: 3A
Rated Voltage: 12V
Model Number: MR-SS0312
Net weight: 0.035kg
dimension: 53.4*68.6*22mm
Place of Origin: China (Mainland)
Unit Type: lot (10 pieces/lot)
Package Size: 6cm x 7cm x 20cm (2.36in x 2.76in x 7.87in)
Package Weight: 0.5kg (1.10lb.)

Specifications

3A 12V/24V PWM Solar Power Charge Regulator for Solar System with LED Display, Workable for Home System or Solar Light (Adjusted according to actual requirement)

Characteritics of the function

1,Equipped with the MCU,artificially controlled.

2,Equipped with device to avoid the over charge,over release,electronic short circuit,over loading,battery inversely connecting,solar battery inversely connecting.

3,The series connection PWM circuit is implemented to form the major charging circuit,make the voltage loss 50% lower than the diode charging circuit,and the charging efficiency 3%-6% higher than the non-PWM.

4,The LED displyer shows the batteries current situation to make the customer get the information of the batteries.

5,The controller can automatically identify the voltage of 6V/12V,12V/24V.

 

The drawings of the controlling panel

3A The drawings of the controlling panel.JPG

 

Cording diagram:

 

3A Cording diagram.jpg

 

Outline dimension and Installation dimension

 

3A Outline dimension and Installation dimension.jpg

 

Indication instruction of LED light

LED

State

Function

Charge

off

Night condition or the battery not connected

Green light on

Battery at balanced charging situation

Slow flash

Battery at floating

Double flash

Day condition

Battery

Red light double flash

Voltage of Battery under 11.0V

Green light double flash

Battery low voltage alarm(11V~12.0V)

Green light Slow flash

Voltage of the battery is normal(11.5V-12.5V)

Green light on

Voltage of the battery is higher than 13.0V

Protection

Red light slow flash

Battery low voltage cut or high voltage cut

Red light double flash

The protection of the load short

Red light on

The protection of the over load

All light in sequence

The controller automatic system voltage

 

Technology index

Model number

MR-SS0312

Solar panel power

 

<=36W

Rated discharge current

3A

System voltage

12V

Over loading and short circuit protection

If the load current great than 3 rate current,close Output at once.If the load current great than 1.5 rate current,close Output delay 5 minutes,open output after 5 minutes.

Self consumption

≤6mA

Charge loop drop voltage

≤0.2V

Discharge loop

drop voltage

≤0.1V

High voltage protection

8.2V(6V)/16.5V(12V)/33V(24V);

High voltage resume

7.5V(6V)/15V(12V)/30V(24V);

Over discharge voltage

5.5V(6V)/11V(12V)/22V(24V);

Over discharge

voltage resume

 

6.4V(6V)/12.8V(12V)/25.6V(24V);

Boost voltage

7.4V(6V)/14.8V(12V)/29.6V(24V);

Charging time 60 minutes

Equalization voltage

7.2V(6V)/14.4V(12V)/28.8V(24V);

Charging time 60 minutes

Float voltage

6.9V(6V)/13.8V(12V)/27.6V(24V);

Charge resume voltage

6.6V(6V)/13.2V(12V)/26.4V(24V);

Working temprature

-20°C~55°C

Outline dimension

and weight

53.4mm*68.6mm*22mm 0.035KG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install and use

1,The preparation of the conducting wire:calculate the length of the wire ,and then figure out the installation place,make sure the length of the wire is reasonable to decrease the loss of the electricity.

2,Connect the battery first,pay attention to the anode and the cathode to avoid the inverse connection.the indicator light of the battery will work if the connection is correct,otherwise,it will not ,but the component of the controller will not be damaged.

3,Connect the wire of the solar panel, pay attention to the anode and

the cathode to avoid the inverse connection.if the connection is correct,the indicator light of “CHARGE”will be on or flash 10 seconds later after laying outside under the sun,otherwise,please check the connection.make sure the solar energy panel is laid outdoors under the sunshine.

4,Connect the load at the end,pay attention to the anode and the cathode to avoid the inverse connection .if inverse connection ,the led lamp may be damaged.

 

Suitable usage range

The controller is only suitable for the solar energy system with the rated voltage of 6V/12V/24V, batteries can be flood or seal,also can be lithium Iron Phosphate Battery.Please offer the category of the battery before ordering.

 

Warnings for usage

1,The batteries has stored much energy,please keep the batteries from the short circuit under any circumstances,we strongly recommend connecting the batteries with the fuse.

2,Please avoid the short circuit wire and the terminal,for the wire and the terminal may generate voltage two times higher than the rated voltage of the controller.Please use the insulated tools while operating the controller.

3,Ensure the children keep away from the battery and the controller.

4,Please comply with the manufacturer`s safety advice.