Product Main

Quick Details

Model Number: A6-SWH-SRC-868-C
is_customized: Yes
Unit Type: piece
Package Size: 40cm x 27cm x 10cm (15.75in x 10.63in x 3.94in)
Package Weight: 1.4kg (3.09lb.)

Specifications

SR86812V-1

Description

 

Model: SWH-SRC-868-C

Manual in English

This listing includes: 1 unit of controller for pressurized solar water heating system, 12V.

 

Application:

It can be used for the solar hot water heating system: 1 collector array – 1 storage tank – 1 pump and auxiliary heating.

 

SRC-81-C-1

QQ20170329144054

Function Introduction:

The solar circuit pump (R1) is switched on as soon as the switch-on temperature difference (△T on) between the collector array (T1) and the storage tank (T2) is reached.

If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (△T off), , or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump (R1) is switched off.

Back-up heating by auxiliary boiler: within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased.

 

Main technical data:

-       Controller dimension: 218mm×165mm×55mm

-       Display dimension:   120mm x 120mm x 18mm  

-       Power  supply:        DC 12V

-       Power  consumption:   < 3W  

-       Accuracy of temperature measuring:  ± 2 Cel. degree

-       Range  of  collector  temperature  measuring:   -10~220Cel. degree

-       Range  of  tank  temperature  measuring:   0~110 Cel. degree  

-       Suitable  power  of  pump:   3 pcs,3A 

-       Suitable power of electrical heater: 1 pcs, Electromagnetic relays, designed for on/off control of back-up heating device, Max. Current: 15A

 

-       Inputs:

l  1 x Pt1000 sensor  (≤ 500 Cel. degree)  for solar  collector  (silicon  cable≤280Cel. degree),  

l  2  x  NTC10K,  B3950  sensor  (≤  135 Cel. degree)  for  tank,  (PVC  cable  ≤105 Cel. degree),  

-       Outputs:  3 relays, for circulation pumps or 3-way electromagnetic valve,  1  relay  for  electrical  heater

-       Ambient  temperature:   -10~50  Cel. degree

-       Water proof: IP40

 

Display illustration:

 

SRC-81-C-2

SR86812V-2sr868-5sr868-3

Payment

· Please pay within 3 days after auction.
· Please contact us for your payment if you have any problem.

Delivery details

· Your item will be shipped within 48 hours in business days if payment for the order is cleared before 8PM PST daily (except Saturday, Sunday and Holidays). If there's an exception, we will inform you.

· Buyer, as the importer, is responsible for paying the customs clearance cost or related TAX.

Terms of sale

· Positive Feedback is our life. Before you leave a neutral or negative feedback, please contact us first to get a better solution. We care our valued customers. So if you have any problems, please contact us immediately. Please give us the opportunity to resolve a problem. We understand the concerns and frustrations you might have and try our best to resolve the issues. Leaving neutral or negative feedback cannot solve the problems.

About us

· Welcome to our store. We are specialized on Energy Saving electronics: Solar water heater and controllers, pump stations, solar charge controller, inverter, SOLAR Lamps, etc.. Please visit us often. We are pleased to work with you!

Contact us

All communication is handled through emails and ALI message. We strive to answer all emails as quickly as possible.