is_customized: | Yes |
---|---|
Application: | Solar System Controller |
Maximum Current: | 30A |
Brand Name: | HF |
Model Number: | SK30D |
Rated Voltage: | 12V/24V |
color: | black |
Unit Type: | lot (5 pieces/lot) |
Package Size: | 20cm x 25cm x 30cm (7.87in x 9.84in x 11.81in) |
Package Weight: | 3.5kg (7.72lb.) |
Quick Details
Specifications
5pcs/lot 30A Solar Charger Controller Regulator 12V 24V Auto Switch for PV System SK30D
1 Four-stage PWM charging mode.
2 Preset charging parameters for three battery types.
3 Detecting mode for battery voltage level is adjustable.
4 Charging and Discharging parameters are adjustable.
5 Temperature compensation is applied.
6 Real-time clock display.
7 Various controlling mode for load.
8 Optional communication function.
9 Protection against reverse connected solar panel and input over-current.
10 Protection against under-voltage, over-voltage, reverses connection and reverse discharge of battery.
11 Protection against over-current and short circuit of load.
12 Protection against internal over-heat.
Please make sure battery and solar panel are disconnected to controller, and do not contact the positive and negative terminals of solar panel and battery at the same time in case of electric shock.
A free space of 15cm on all sides must be provided for better heat dissipation. Current density control system wiring cables within the 3A / mm2.
- Make sure installation site meets safety requirements first.
- Make sure voltage of solar panel and battery are compatible with controller.
- Connect battery to controller and check whether the LCD display is on, if not, please solve the problem as mentioned in chapter 5.2.
- Connect solar panel to controller accordingly. If there’s sunlight, controller starts charging battery immediately and charging indicator arrow on LCD on.
- Connect load to controller
Model |
SK30D |
SK40D |
SK3048D |
SK4048D |
SK3048DA |
SK4048DA |
Input |
||||||
PV voltage |
≤50V |
≤100V |
12V/24V ≤50V 36V/48V ≤100V |
|||
Rated current |
30A |
40A |
30A |
40A |
30A |
40A |
Output |
||||||
System voltage |
12V/24V (Auto) |
48V |
12V/24V/36V/48V (Auto) |
|||
HVD |
16.00V×1/×2/×3/×4 |
|||||
Rated current |
30A |
40A |
30A |
40A |
30A |
40A |
No-load loss |
≤13mA |
≤15mA |
≤25mA |
|||
Charge loop voltage drop |
≤0.17V |
≤0.28V |
≤0.17V |
≤0.28V |
||
Discharge loop voltage drop |
≤ 0.10V |
≤ 0.10V |
≤0.10V |
≤0.10V |
Discharge loop voltage drop |
≤ 0.10V |
≤ 0.10V |
≤0.10V |
≤0.10V |
Charging mode |
PWM 4-stage(bulk, absorption,float, equalized) |
|||
Voltage of float charging |
13.8(13V~15V)×1/×2/×3/×4 |
|||
Voltage of absorption charging |
14.4V(13V~15V) ×1/×2/×3/×4 |
|||
Duration of absorption charging |
2hs |
|||
Voltage of equalized charging * |
14.6V(13V~15.5V) ×1/×2/×3/×4 |
|||
Duration of equalized charging |
2hs |
Duration of equalized charging |
2hs |
LVD |
10.7V(10V~14V) ×1/×2/×3/×4 |
LVR |
12.6V(10V~14V) ×1/×2/×3/×4 |
Load working mode |
Regular control mode Light control with switch-off point at night and switch-on point before dawn Light control mode Self-timing switch on/off mode |
Light control voltage |
5V(1V~10V) ×1/×2/×3/×4 |
Battery type |
GEL, SLD, FLD and USr(default) |
Other |
|
Buttons |
LCD, 3 buttons |
Heat sink |
AL alloy heat sink |
Wiring |
PCB terminal, ≤16mm2 |
|||
Working temperature |
-20 ~ +55 °C |
|||
Storage temperature |
-30 ~ +80 °C |
|||
Working humidity |
10% ~ 90%, no condensation |
|||
Dimension |
196 x 111 x 54 mm |
|||
Net Weight |
401 g |
403 g |
410 g |
412g |
IP grade |
IP30 |
|||
Optional function |
Remote communication,TTL, standard ModBus protocol |
|||
Accessory |
Temperature sensor |
Battery Type
Battery type |
Voltage of float charging (V) |
Voltage of absorption charging(V) |
Time of absorption charging(h) |
Voltage of equalized charging(V) |
Time of equalized charging(h) |
Interval of equalized charging(day) |
GEL |
13.8 |
14.2 |
2 |
--.- |
- |
-- |
Sealed |
13.8 |
14.4 |
2 |
14.6 |
2 |
28 |
Flooded |
13.8 |
14.6 |
2 |
14.8 |
2 |
28 |
User |
13.8 |
14.4 |
2 |
14.6 |
2 |
28 |
Manufacturer provides 1 year warranty from invoice date for solar charge controllers.
Please read the following instructions carefully. Free guarantee service will not be provided to the said equipment if
1.It has been installed and operated otherwise than in accordance with the instructions
2.Any unauthorized repair or modification has been carried out on the unit.
3.It has been damaged through natural calamities.
4.It has been damaged through transportation or storage.
5.Batch numbers, serial numbers or identification-marks are manipulated or are unidentifiable.
6.Load connected has been damaged due to incorrect, reversed connection as controller is equipped with solar panel and battery reverse connection protection, but no REVERSE LOAD CONNECTION PROTECTION.
7.It has been used to control power generated from any other type of device such as a Gasoline Generator rather than a solar panel to charge a lead acid battery.