is_customized: | Yes |
---|---|
Application: | Thermal Controller |
Maximum Current: | N/A |
Model Number: | MS-SWH-SRC-C8Q-A |
Rated Voltage: | 110V |
Place of Origin: | Zhejiang, China (Mainland) |
Unit Type: | piece |
Package Size: | 40cm x 27cm x 10cm (15.75in x 10.63in x 3.94in) |
Package Weight: | 1.9kg (4.19lb.) |
Quick Details
Specifications
This auction includes: 1 set of full controller kit for solar water heater, Including: Display, controller, 5 sensors 110V
Application: it is used for seperated pressurized solar water heating system.
Main technical data
Appearance of controller 120mm×120mm×18mm
Power supply AC230V±10% (or AC110V+/-10%)
Power consumption < 3W
Accuracy of temperature ±2oC
measuring Range of collector -10~220oC
temperature measuring Range of tank 0~110oC
temperature measuring
Suitable power of pump three pumps,≤ 600W
Suitable power of power ≤ 1500W
electrical heater Inputs
2pcs x Pt1000 sensor (500oC)for collector (silicon cable≤280oC),
3pcs x NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
Outputs
3 relays, for circulation pumps or 3way electromagnetic valve
1 relay for electrical heater
Ambient temperature -10~50 oC
Water proof grade IP40
Introduction:
1 collector array 1 storage tank
1 pump and auxiliary heating Description: The solar circuit pump (R1) is switched on as soon as the switch-on temperature difference (Ton) between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (Toff), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( R1) is switched off. Back-up heating by auxiliary boiler (detailed see paragraph 4.3): Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased.
Main functions
1.Main menu DT O & DT F Temperature difference function
2.Main menu-THET timing heating
3.TEMP Temperature main menu
4.EM Emergency collector temperature
(emergency switch-off temperature of collector)
5.CMX Maximum limited collector temperature (collector cooling function)
6.CMN low temperature protection of collector
7.CFR frost protection of collector
8.SMX Maximum temperature of tank
9.REC Tank re-cooling function
10.Celsius and Fahrenheit temperature transferring
11.FUN Auxiliary function
12.DVWG Anti-Legionella function
13.CIRC Temperature controlled hot water circulation pump
14.nMIN Solar circulation pump speed adjusting (RPM speed controlling)(Only available on SR868C8Q)
15.OHQM Thermal energy measuring (Only available on SR868C8Q)
16.INTV Pump interval function (Only available on SR868C8Q)
17.BYPR High temperature by-pass function
(tank temperature automatically adjusting)
18. HND Manual mode
19.PASS Password setting
20.LOAD Recovery to factory setting
21.ON/OFF button
22.Holiday function
23.Manual heating
24.Temperature query function
25.Memory Protection
26.Anti-dry heating Protection
27.Screen protection
Payment
· Please pay within 3 days after auction.
· Please contact us for your payment if you have any problem.
Terms of sale
· Positive Feedback is our life. Before you leave a neutral or negative feedback, please contact us first to get a better solution. We care our valued customers. So if you have any problems, please contact us immediately. Please give us the opportunity to resolve a problem. We understand the concerns and frustrations you might have and try our best to resolve the issues. Leaving neutral or negative feedback cannot solve the problems.
Delivery details
· Your item will be shipped within 48 hours in business days if payment for the order is cleared before 8PM PST daily (except Saturday, Sunday and Holidays). If there's an exception, we will inform you.
· Buyer, as the importer, is responsible for paying the customs clearance cost or related TAX.
About us
· Welcome to our store. We are specialized on Energy Saving electronics: Solar water heater and controllers, pump stations, solar charge controller, inverter, SOLAR Lamps, etc.. Please visit us often. We are pleased to work with you!
Contact us
· All communication is handled through emails and ALI message. We strive to answer all emails as quickly as possible.