Product Main

Quick Details

Unit Type: piece
Package Size: 20cm x 20cm x 20cm (7.87in x 7.87in x 7.87in)
Package Weight: 0.04kg (0.09lb.)

Specifications

 
 
 
 
 
 
 
Product Categories
ZY1270 large color screen with Bluetooth needs to be scheduled
ZY1270 large color screen need to be scheduled
ZY1272  Small color table  
ZY1273Small yellow table
Small yellow table ZY1273 on sale! Color TFT display! USB3.0 high current 5A interface! Support OPPO flash charge, DASH flash charge! Support TypeC line function! Latest 3.1 system!
This instrument features more upgrades more frequently, it is recommended to upgrade with a brush line STLINK and 6 spring pin 1
Bluetooth serial port function: You can even computer or mobile phone to send test data, and in the computer or mobile phone to draw the graph. PC to step up the development, the only temporary assistance with the serial port + excel drawing. Note that Bluetooth can not be used to upgrade the usb table, only stlink upgrade.
Color TFT LCD display, rich colors, high resolution, display more information, fonts larger and easier to read
New dual USB port, one of the port to support accelerated charging, you can plug the phone into the computer can also be close to full charge, and avoid charging the public computer caused by the virus.
Other features and ZY1266 the same green table, equivalent to the advantages of all the previous models, larger size.
 
Positive with Z flash logo is the intelligent acceleration port, but can not change the voltage is 5V input can not become 9V recommended computer charger or unofficial charger to use when charging the phone, the opposite is a straight port with USBlogo.
Note that the output QC9V or higher voltage is prohibited when dual-use at the same time, or may burn the phone!
Accelerated charging: can be inserted into the computer USB port or non-original USB charger, the charge identification signal automatically becomes the original charger, so that the phone that plug into the original charger to speed up the charging speed. Note that this function can not change the output voltage, does not support the normal charger change QC2.0 charger, can not enlarge the output current.
 
Charger Type: USB port can be inserted into the unknown or mobile power USB port, the USB port to detect the specific charge identification signal, easy to identify what is suitable for mobile phone charging. Use this feature is not recommended to pick up the phone, otherwise the phone will interfere with recognition.
 
Safety Monitor: When the input voltage is too high or too low, the temperature is too high, the output current is too large or too small to maintain the set time will activate the USB security monitoring protection function, cut off the output to prevent accidents. Can be used to charge the phone at night, full of power after the full; protection of the wrong voltage and current input cell phone damage; charger adapter overheat to stop charging. If you want to restore the output after protection, please press the key to restore the output on D + D- voltage page.
 
D + D- voltage: that is, data line voltage, based on this voltage can distinguish most of the charger type. You can refer to this voltage to help determine the USB port charging recognition mode.
 
Plastic shell: a plastic shell version of the dust into the debris to prevent a lot of good performance, not touch the circuit is not easy to interfere with the circuit work. PCB frame version without shell, but the three-tier structure of the core circuit protection is also very good, good heat dissipation.
 
Interface: divided into USB3.0 and USB2.0, USB3.0 backward compatible with USB2.0, USB3.0 can be used to test USB3.0 device operating current, USB2.0 interface is more suitable for testing ordinary charger and USB2 .0 device operating current.
 
Voltage: Input voltage range, it is recommended to work within the nominal value, if less than the nominal value may not work, higher than the nominal value of the accuracy of low or even burned. ZY1252 new record to become the first to support 24V USB table.
 
Current: Input the current range, it is recommended to work within the nominal value, greater than 3A can also be normal display, but the USB port can not afford a large current may burn USB port. Circuit board sampling resistor maximum support 6A, for more current can be changed for external sampling resistor to support 20A.
 
Resolution: the minimum voltage or current capacity can be read to change the value of the smaller representative of the higher resolution, can distinguish the more subtle voltage and current capacity changes.
 
Accuracy: The percentage accuracy of the final reading and the range of the last bit reading. The smaller the percentage, the higher the accuracy. The smaller the run-out range, the more stable the reading will be. ZY1252 to a new high to become the first to support 0.1mV 0.1% accuracy, 5 effective reading, automatic range 0-30V voltage test USB table.
 
Line Loss: Contains current sample loss and USB contact resistance loss. The smaller the value is, the smaller the voltage loss is. ZY1230 and ZY1231 is already USB table limit, but the new ZY125x series is a new low.
 
Amperes capacity: Amperes per hour, 1A current to maintain 1 hour compared with 1Ah, 1Ah = 1000mAh, the domestic mobile power and battery capacity of the most commonly used units. Measuring battery capacity and mobile power capacity commonly used.
 
Watts capacity: Watts per hour, 1W power to maintain 1 hour compared with 1Wh, 1000Wh = 1 kWh, compared to Ah expression more accurate, so the whole world. Since power = voltage x current, Ah * voltage = Wh. This parameter measurement of mobile power capacity more accurate and convenient, with the energy meter can also measure the efficiency of the charger.
 
Charging time: When the charging current is greater than the set trickle shielding current, the time starts to go. Use this function to measure the time required for the device to fill. It can also be used to accumulate the amount of time the device is operating. V2.5 version of the new features.
 
Temperature: the temperature of the built-in chip, if no load without fever, the reading approximates the ambient air temperature. V2.5 version of the new features.
 
Memory: All current models are ferroelectric FRAM memory, similar to the infinite number of 10000000000 erase life, so as to ensure 1 second to save a capacity, 300 years is not bad legend. So far the only USB table with this high-end memory.
 
Static power consumption: default brightness of the screen, the USB table of consumable current. The machine uses a 32-bit processor + external ADC, all models are new lows, as low as a stable 6mA off the screen power, any voltage input is 6mA, if used to measure the mobile power, regardless of how much voltage fast charge , More than 6mAh per hour can be, simple and accurate.
 
MicroUSB line function: with the constant current source can quickly detect the data line resistance, loss of line loss and other parameters, the players select a higher quality data lines
b1b2b3b4
Performance parameters:
 
Size: 75 * 30 * 15mm
 
Weight: Contains iron box 55g, bare metal 22g
 
Voltage range: 3.5-24V, the ultimate pressure 28V
 
Voltage resolution: 0.0001V (18bit)
 
Current range: the average positive and negative 0-3A, can instantly maximum 24A (continuous over 3AUSB mouth can not afford to Kazakhstan) to change the current can choose to store large 10mA shunt direct support 24A
 
Current resolution: 0.0001A (0.1mA 18bit)
 
Capacity range: 0-99999Ah 0-99999Wh, in fact, 999999 and 9999999 also support, but the decimal point is not in, only shows the high 5
 
Capacity Resolution: 0.0001Ah 0.0001Wh (0.1mAh 0.1mWh)
 
 
 
Instructions for use:
 
Measuring voltage and current:
 
USB plug into any USB port, plug the mother cell phone and other equipment, direct reading of the voltage and current parameters
 
Measurement of mobile power output capacity and efficiency:
 
It is recommended to use dummy load with resistor, plug the USB plug into the mobile power supply, and insert the dummy load into the socket until the discharged power of the fully charged power supply is finished. The next time you turn on the unit, the display capacity is Ah and Wh for the mobile power output.
 
ZY1270 Edition uses intelligent identification to speed up the charge:
 
If not with the official charger, such as the Samsung charger to charge the apple, or through the computer USB charging, charging speed may be slow or even refused to charge, you can plug into the upper USB port to accelerate charging. Note 1A charger is not possible to output 2A, the energy conservation Oh.
 
Calculation of mobile power battery capacity and efficiency:
 
Ah data x output voltage ÷ battery voltage ÷ efficiency = mobile power battery Ah (output voltage is generally 5V, you can view the capacity of the second screen, the average voltage, the battery voltage is generally by 3.7V, efficiency generally 85-90% Or high-end mobile power by 95%), or Wh data ÷ efficiency = battery Wh (so measured Wh more simple calculation), battery Wh ÷ battery voltage = battery Ah, Ah ÷ 1000 = mAh. If you know the built-in battery capacity and voltage, you can calculate the mobile power efficiency: (Ah data x output voltage) ÷ (battery capacity x battery voltage) = mobile power efficiency, or Wh data ÷ battery Wh = mobile power efficiency
 
Measuring the power adapter / charger efficiency:
 
With the meter (your home distribution box that goods) and false load use. After the meter is only connected to the measured charger, charger output USB table and false load, run for some time, check the USB table accumulated Wh data, and then check the meter to go the number of degrees, 1 kWh = 1000Wh, with USB table reading ÷ Meter reading change = Accurate charger efficiency. (In fact, turn the number of meter wheel turntable more convenient, the general meter will be marked with a circle is 0.00x degrees)
 
Measured data cable / USB cable / other USB table resistance:
 
 
 
With dummy load use. First of all, insert the power on the USB table, switch to the measuring line resistance function, and then plug in precision dummy load transferred to the required test current (recommended greater than 0.5A less than equal to 2A), read the long press the button to record the reference voltage and current. Then unplug the USB table, with the test data cable / cable / other USB table directly plug the power supply, then the USB table inserted into the measurement line, false load fine-tuning to the current equal to the reference current as much as possible. You can read out the resistance of the wire under test and test current line loss voltage drop
 
Measuring battery capacity:
 
Using TP4056 and other linear charging circuit through the capacity table to completely charge the battery fully charged to full capacity readings for the battery capacity, the use of this method can also be measured about the phone charge capacity (as far as possible with the USB cradle, because the phone is generally not Linear charge, and standby power consumption interference)
 
Measuring the current of small equipment and standby current:
 
 
 
Low 0.1mA high-resolution high-precision current, easy to detect almost all small USB devices operating current / standby current, such as card readers, wireless mouse receiver, Bluetooth or LAN adapter.
 
Trickle-down function to measure charging time / capacity:
 
Most of the mobile phone is still full of trickle current, if not shield the capacity will continue to increase the trickle, interference test. When the charge current is less than the set value after setting the trickle screen, the capacity and accumulated charging time will not increase, so the charging time and charge capacity can be measured more accurately. Set to 0 to disable the trickle mask function.
 
Measurement of electrical equipment to detect the power output capacity of the current waveform:
 
 
 
High-speed current curve drawing (up to 1 second 3 times) can be used to draw electrical equipment after testing the power supply current waveform. Development of self-adaptive electrical equipment essential tool!
 
Data clear:
 
Pressing and holding the key will first jump to the next group and continue to hold for a few seconds, jumping back to the current group and resetting to the current group and resetting the current group to zero. The function 1 and function 2 interface (ie, the first line shows the current; The current group, that is, to complete the zero operation
 
Data View:
 
Parameter interface Long press to switch to the next group
 
Shortcut screen rotation:
 
Display D + D-voltage interface and display large font voltage and current interface, long press the button to rotate the display direction
 
Power on:
 
Through the USB male power, the display shows about 1 second after the LOGO into the parameter interface
 
Display Parameter Switching / Closing Display:
 
Parameter interface Short press to switch the display parameter / function and to turn off the display
 
Restore the backup settings; restore factory settings:
 
Press and hold the button until the setting is displayed, press to switch to 09 - press to restore the backup settings, short press to switch to 07 - long press to restore the factory settings, note that the factory settings are not calibrated. After the shipment is calibrated, the shopkeeper will back up a good calibration setting, and suggest that you do not use it easily 08 - The backup settings cover the correct calibration parameters
 
Data calibration function settings:
 
An electronic load instrument, an adjustable power supply.
 
Press the button and then turn on the power, about 5 seconds to show Setting and then let go, after the show 10 - show the version number below 2.0
 
Press the button to switch to the display 00--, adjust the power to the precise 5V, first do not take any load, to be below the 0S voltage reading is relatively stable long press the button, the system automatically records the current voltage of the standard 5V
 
Press the button to switch to display 01--, electronic load CC constant current mode, transferred to the precise 2A, access USB female port, to be 1S below the current reading is relatively stable long press the button, the system automatically records the current current standard 2A
 
After the completion of 10 - long press or direct power to automatically save the settings
 
 
 
 
 
 
 
 
 
Payment
 
if  you have any problems of payment please contact us!
 
if you need to buy more goods but the price isnotvery cheap please contact us!
 
Warranty
 
All products have been checked and packaged in good condition before dispatch.
 
ALL peoducts have 1yeas warranty.
 
If you are not satisfied with our product and service.Please contact us first  before giving a non positive feedback or dispute.we will try to our best solve the problems
aa