Product Main

Quick Details

Application: Lighting Controller,Solar System Controller,Charger Controller,Solar Working Station,Voltage Controller
Model Number: MPPT-10A
Maximum Current: 10A
is_customized: Yes
Brand Name: Y-SOLAR
Rated Voltage: 12V 24V
Max input power: For 12V Pv System:150W For 24V Pv System:300W
Charge Mode: MPPT SOLAR CHARGE CONTROLLER
Full charge cut: 14V(12V) 28V(24v)
Low voltage cut: 10.5V(12v) 21V(24V)
Reconnected voltage: 12.6V(12V)25.2v(24V)
Unit Type: piece
Package Size: 15cm x 10cm x 5cm (5.91in x 3.94in x 1.97in)
Package Weight: 0.7kg (1.54lb.)

Specifications

MPPT 10A Solar Charge Controller LED 12V 24V Auto Solar Panel Battery Regulator 

Package: 

1.1xMPPT Solar Controller 10A

2. 1x Users` manual

True MPPT,transformer coil inside.

Compared with normal solar charge controller, this MPPT controller could increase 10%-30% electrical power using efficiency from solar panel.

Feature:

The most outstanding feature of Maximum Power Point Tracking controller is intelligent tracking input voltage from solar panel, which could let solar panel always working at Maximum Power Point of V-A curve. Compared with normal solar charge controller, this MPPT controller could increase 10%-30% electrical power using efficiency from solar panel.

Function:

MPPT 10A solar charge controller regulator is not only have above mentioned special function, at the same time including completely Protecting and Controlling functions:

Overcharge protection Over-discharge protection Battery Reverse Current Protection Overloading Protection 

Short Circuit Protection Reverse Polarity Connection Protection

 

Thank you very much for selecting our product

This manual offers important information and suggestions with respect to installation, use and troubleshooting, etc. Please read this manual carefully before using the product and pay attention to the safety recommendations in it.

This MPPT controller is not only have above mentioned special function,at the same time including completely Protecting and Controlling functions:

Overcharge protection

Over discharge protection

Battery Reverse Current Protection

Overloading Protection

Short Circuit Protection

Reverse Polarity Connection Protection 

 

Model

MPPT-10

MPPT-20

Rated voltage

DC:12V / 24V 

Max current

10A

15A,20A,

No load loss

≤8mA/12V / 24V 

Voltage drop

≤300mV

Max voltage of solar panel

23V/12V,23V×2/24V,

Full charge cut

14V/12V,×2/24V,

Low voltage cut

10.5V/12V,×2/24V,

Reconnected voltage

12.6V/12V,×2/24V,

Temperature compensation

-3mV/cell. °C

Efficiency

95%-97%

Wire area

1-2A/ mm

Electrical power using efficiency

Can increase 10-30%

Net Weight

0.55Kg

0.65Kg

Dimension

188×93×55mm

188×118×55mm

 

Form a complete set:
 
Solar Panel: 12V solar system should use 40pcs cells laminated solar panel. The maximum power point voltage is over 18V. 24V solar system should use 2pcs above mentioned solar panels. 
Conductor: The cable between solar panel with MPPT solar charge controller should be better calculated by 1Ampere per 1mm2.
Solar Charge Controller: We have 12V, 24V and 48V three kinds of MPPT solar charge controllers with 10A, 20A, (other specifications could be designed as customer special request). Fit for power of solar panels:
MPPT-20—200Wp(12V), 40—400Wp(24V), 
Connection:
 
1.Connected the “+”, “-” poles of the battery to the controller (3, 4 from left) firmly and correctly. At this time the LOAD green LED is bright. If the LOAD green LED is not bright, it is indicate there is battery reverse polarity connection. Only LOAD green LED is bright, we could continue next step operation.
2.Connected the “+”, “-” poles of the solar panel to the controller (1,2 from the left) firmly and correctly.
3.Connected the “+”, “-” poles of the LOAD to
the controller (5,6 from the left) firmly and correctly
Simply Measure Method:
 
For 12V system, measure the input voltage from solar panel with multimeter (terminal 1, 2 of controller), it is normal if the voltage of solar panel more than battery voltage 0.5-6V. Generally, the higher input voltage, the better charge efficiency. For 24v and 48V system, the input voltage will be much more higher than battery voltage
(Note: It is normal phenomenon the controller can not find Maximum Power Point within 10 minutes from system start.)
Indicator:
 
1.Load indicator, green, bright indicate there is output, Load could work, “off” indicate there is not output, and Load can not work.
2.Low Voltage Indicator, red; bright indicate the voltage of the battery is low. Load could not normal working. This is normal phenomenon. When the battery voltage recover to 12.6V or (25.2v), the Load will be automatically working, at this time the indicator is off.
3.Charge Indicator, red, bright indicate the battery need to charge, flickering means float charging, off means charge has stop.
 
RESET Button:
 
Please notice the rated current of your controller, if there is short circuit or overload happened, the MPPT controller will close output. (Load indicator off, Low voltage indicator off.)
If you need the MPPT controller recover work, please check the reasons and clear out the fault firstly. Then put a small stick such as toothpick, ball-pen tip inside the RESET hole, and press RESET button will be OK.
 
Attention:
 
1.Please check the rated voltage of the solar panel, battery, and load are all the same with 12V or 24V or 48V.
2.Please pay attention to connection, do not connect the “+” “-” poles of solar panels and loads wrong.( Wrong connection will be burn your MPPT controller)
3.Battery must be connected earlier than solar panels and load. When take off the system, Solar Panels must be take down first, then cut off battery.
 
 
 
mppt-10-1mppt-10-2
 
393938