ACEHE 1pc 30A 12V/24V Professional LED Screen PWM Solar Panel Battery Regulator Charge Controller CMTP02-30A Black Sale
Features:
Solar charge controller
Electronic protection
Fully automatic operation
PWM charge mode(SOC)
Microcontroller digital accuracy
Suitable for all 12/24V DC lamps
Big terminals,big distance between terminals
Double digital LED display,numbers equal to timer setting
Temperature compensation(with external temperature sensor)
Always keep the battery on fill voltage condition.
Prevent the battery from over-charging.
Prevent the battery from over-discharging.
Prevent the battery from reverse charging to solar panels during nights.
Reverse Polarity Protection for Battery
Reverse Polarity Protection for Solar Panels
When the battery voltage is low, the controller will automatically cut off the load from the system. If the voltage of
battery is back to normal and the load will restart working.
Thunder protection
According to the battery voltage grade, the controller can automatically set charge-off voltage, the load-off voltage,
the load- restore voltage. (The parameter is default under 25° condition, locked by the CPU procedure, cannot adjust.)
The controller will automatically compensate the temperature of the charging voltage according to the changes of
ambient temperature.
Specifications:
Model:CMTP02
Rated Voltae :12V / 24V
Max Load current: 30A
Input voltage range: 12V20V/24V~40V
Length≤1m:Charge loop drop:<250mV
Length≤1m:Discharge loop drop: <50mV
Full charge cut: 1.374.4V/27.4V28.8V (data under no load condition)
Low voltage cut: 10.5V11V/21V22V
Temperature compensation: -3mV/°/cell
No load loss: ≤20mV
Efficiency: 95%97%
Max wire area: 6mm2
Ambient temperature -25 ° -55 °
Color-changing LED working voltage indicates area:
Color-changing LED:12V 24V
Red LED: 10.5V-11V 21V-22V
Orange LED: 10.511V-13.7V 212V-27.4V
Green LED: ≥13.7V ≥ 27.4V
Color:Black
Size:133 x 70 x 31 mm
Net weight:108 g
Package weight:128 g
Package included:
1 x PWM Solar Charge Controller
Manual
SAFETY
Full consideration to the safety of persons and property has been given when designing the products.
However the incorrect connection may cause the system breakdown or even safety accident. For your safety and benefits, the following rules must be complied during the operation.
Installation of this product shall be tinder the guidance of the professionals in this field.
Prevent this controller from water, humidity and insects, to avoid short-circuit.
Keep children and incapable persons away from the controller
Keep the controller away from electrical heater, heating machine and other high temperature electrical
appliances; avoid the controller suffering from insulation directly.
Please check the rated voltage of solar panel, battery, and loads before connection. 12V rated voltage is 12V, 24V rated voltage is 24V.
Make sure connections between positive and negative poles of Solar panels, Battery and Loads are correct.
The diameter of connecting cable must be matched with the requirements of the current. Do not use thinner diameter cable, the thinner diameter. The larger resistance, this will cause higher temperature and output power
decreasing.
The total rated current of solar panel and loads must be smaller than the rated current of the controller.
Components of system must be correctly and firmly connected. Prevent the terminals from oxidation and moldy,to avoid connection trouble.
Warning:
Before connecting to the solar panel, please connect the controller to the battery; do not use solar panel supply power
to the loads directly.
Notes:
Do not use lamplight to charge the solar panel (lamplight is too weak to charge)
DC power source to replace the solar panel will cause troubles to controller.
Choose the suitable wire which diameter should not be too small, please refer to the parameter.
INDICATE LIGHT AND BUTTON.
When Red LED (CHARGE) is on, battery is charged up strongly; When Red LED is flickering, battery is MPPT charged up in constant voltage; when Red LED is oft charge off
When Green LED (LOAD) is on, loads are working; when Green LED (LOAD) is off, loads stop working.
Three Colorchanging LED (BATTERY), When light is red, it indicates low voltage, green indicate battery full charged, orange indicate normal status.
TROUBLE SOLUTION
Phenomenon:Green LED off, battery indicator LED is red.
Reason: Low voltage of battery
Solution:
A:Cut off the power, disconnect the load; reconnect the load after the charge become normal.
B:Battery charge problem: Increase the solar panel power or change the battery.
Phenomenon:Battery indicator LED is orange and Load indicator LED is green, the loads cannot work.
Reason:Over load or short-circuit causes the controller inner fuse cut off
Solution: 10-20 minutes after eliminated the malfunction, the fuse will automatically back to working.