Item Type: | Lighting Transformers |
---|---|
Certification: | CCC,FCC,RoHS |
Material: | 1 |
Input Voltage: | 1 |
Output Signal: | 1 |
Input Signal: | 1 |
Output Voltage: | 1 |
Warranty: | 2 |
Model Number: | S-1200 |
is_customized: | Yes |
Unit Type: | piece |
Package Size: | 1cm x 1cm x 1cm (0.39in x 0.39in x 0.39in) |
Package Weight: | 3.0kg (6.61lb.) |
Quick Details
Specifications
Specification:
Model | S-1200-12 | S-1200-24 | S-1200-36 | S-1200-48 | |
output | DC voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1% | ±1% | ±1% | ±1% | |
Rated current | 100A | 50A | 33A | 25A | |
Current range | 0~100A | 0~50A | 0~33A | 0~25A | |
Rated power | 1200W | 1200W | 1188W | 1200W | |
Ripple&noise | 200mvp-p | 240mvp-p | 300mvp-p | 300mvp-p | |
DCvoltage ADJ.range | ± 10% | ±10% | ±10% | ±10% | |
input | Voltage range | 90~132VAC/180~264VAC, 255~373VDC | |||
frequency | 47~63HZ | ||||
AC current | 24A/115VAC,12A/230VAC | ||||
efficiency | 80% | 82% | 83% | 84% | |
Inrush current | Cold start current 30A/115VAC,60A/230VAC | ||||
Leakage current | < 3.5mA/240VAC | ||||
protection | overload | Rated output power115%~135% start over load protection | |||
protection type:cutoff output,recovery after restart power | |||||
Over voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
protection type:cutoff output,recovery after restart power | |||||
Over temperature | detect on heatsink of power transistor≥85°C start over temperature protection | ||||
Protection mode:cutoff output,auto-recovery after temperature become normal | |||||
environment | Working temp,humidity | -10°C~+60°C,20%~90%RH | |||
Storagetemp,humidity | -20°C~+85°C,10%~95%RH non-condensing | ||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | ||||
Fitstandard | Safety standard | Conform to UL1012 | |||
EMC standard | Conform to EN55022,CLASSA | ||||
others | Dimension |
345*133*69mm(L*W*H) | |||
Weight/packing | 2.62kg/8pcs/20kg | ||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance:includes set up tolerance, line regulation and load regulation. |