Item Type: Lighting Transformers
Warranty: 2 years
Plug Type: None
Certification: CE
Weight: 0.9kg
Model Number: NES-100W
Output Voltage: 5v 12v 24v 15v 48v
Output Signal: DC
Features: full power
Input Signal: AC
Input Voltage: 85 ~ 132VAC / 176 ~ 264VAC selected by switch
Material: metal
Unit Type: piece
Package Size: 20cm x 15cm x 5cm (7.87in x 5.91in x 1.97in)
Package Weight: 1.1kg (2.43lb.)

Specifications

 Product Description                                                                  

Features : 

• Universal AC input by switch

• Protections: Short circuit / Over load / Over voltage

 Cooling by free air convection

 LED indicator for power on

 100% full load burn-in test

MODEL

NES-100-5

N ES-100-12

NES-100-15

NES-100-24

NES-100-48

 

 

 

 

 

 

 

     OUTPUT

 

 

 

 

 

DC VOLTAGE

5V

12V

15V

24V

48V

RATED CURRENT

20A

8.3A

6.7A

4A

2A

CURRENT RANGE

0 ~ 20A

0 ~ 8.3A

0 ~ 6.7A

0 ~ 4A

0 ~ 2A

RATED POWER

100W

100W

100W

100W

100W

RIPPLE & NOISE (max.)

80mVp-p

120mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V

11.4 ~ 13.2V

14.25 ~ 16.5V

22.8 ~ 26.4V

45.6 ~ 52.8V

VOLTAGE TOLERANCE

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load

HOLD UP TIME (Typ.)

30ms/230VAC 25ms/115VAC at full load

 

 

 

     INPUT

 

 

 

VOLTAGE RANGE

85 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC

FREQUENCY RANGE

47 ~63Hz

EFFICIENCY(Typ.)

80%

83%

84%

86%

86%

AC CURRENT (Typ.)

2A/115VAC  1.2A/230VAC 

INRUSH CURRENT (Typ.)

COLD START 36A

LEAKAGE CURRENT

<2mA/ 240VAC

 

 

 

PROTECTION

OVERLOAD

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~6.75V

13.8 ~ 16.2V

17.25 ~ 20.25V

27.6 ~ 32.4V

55.2 ~ 64.8V

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +60”C (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85°C, 10 ~95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 ~ 50°C)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X, Y, Z axes

 

OTHERS

 

MTBF

320.7Khrs min. MIL-HDBK-217F (25°C)

DIMENSION

159*97*38mm (L*W*H)

PACKING

0.56Kg; 30pcs/16.8Kg/0.97CUFT

 

NES-100_01NES-100_02