Item Type: | Ballasts |
---|---|
Unit Type: | piece |
Package Size: | 2cm x 2cm x 2cm (0.79in x 0.79in x 0.79in) |
Package Weight: | 1.0kg (2.20lb.) |
Quick Details
Specifications
IPL Lamp Driver
The IPL lamp power supply is used to drive 1 2 or 3 pulsed lamps used in beauty industry. It is easily operated.
Product Introduction
Model | Input | Output power | No. of driven lamps | Max. output voltage | Display | Weight | Dimension (cm) |
---|---|---|---|---|---|---|---|
ST-IPL-03-1 | 220VAC | 300W | 1 | 360V | 240x128 LCD | 3kg | 16x18x14 |
ST-IPL-04-1 | 220VAC | 400W | 1 | 360V | 240x128 LCD | 3kg | 16x18x14 |
ST-IPL-10-1-A | 220VAC | 1000W | 1 | 360V | 240x128 LCD | 5kg | 20x27x14 |
ST-IPL-10-1-B | 220VAC | 1000W | 1 | 360V | 240x128 LCD | 5.2kg | 19x24x14 |
ST-IPL-08-2 | 220VAC | 800W | 2 | 400V | 240x128 LCD | 5.7kg | 20x30x14 |
ST-IPL-10-2 | 220VAC | 1000W | 2 | 360V | 240x128 LCD | 5.7kg | 20x30x14 |
ST-IPL-10-2-1 | 220VAC | 1000W | 2 | 360V | colour touch screen | 6kg | 25x30x14 |
ST-IPL-10-3 | 220VAC | 1000W | 3 | 360V | 240x128 LCD | 8kg | 38x31x14 |
ST-IPL-30-1 | 3P 208VAC | 3kW | 1 | 450V | 240x128 LCD | 70kg | 44x44x40 |
ST-IPL-30x2-1x2 | 3P 208VAC | 2x3kW | 2 | 450V | 240x128 LCD | 140kg | 88x44x40 |
Description of Model: ST- IPL-XX-YY-Z
ST- | IPL | XX | YY | Z |
Model | IPL driver | Output power, unit=100W | Number of driven lamp | Others |
Remark:When multi-lamp is driven, the lamps are not simultaneously driven. If all lamps are simultaneously driven, the total output power will be summed by all lamps.
Fluence: setting of pulse energy, range 05 to 35, corresponding to output voltages 130 to 360V.
Pulsewidth: setting of pulse width, range 05 to 35ms.
Number of pulses: setting of pulse number, range 01-07.
Interval between pulses: spacing of neighbour pulses.
Pulse counter: counting the pulse number.
Specifications of ST-IPL-30x2-1x2
Model | ST-IPL-30x2-1x2 | |
---|---|---|
DC Voltage control | 100 – 450 V | |
Capacitor | 450 V/ 100, 000 uF | |
Repetition Rate | 1 Hz | Frequency of triggering (one triggering can include multiple pulses) |
Pulse sequence | 10 Hz | Pulse frequency in each triggering |
Pulse number control | 1 – 100 | Through LCD controller |
Pulse duration | 1 – 100 ms | Through LCD controller, 0.1 ms step increase |
Pulse gap | 5 – 100 ms | Through LCD controller, 1 ms step increase |
Simmer trigger error check | yes | |
Dual output | 2 x 3 kW | 2 separate LCD, to control each channel output |
Power | 3P 208VAC/50-60Hz or 3P 380VAC/50-60Hz |