16A 4KW Room Electric Heating Plug In Thermostat with EU,UK,Italy,France
Product operation
1.Power off(power icon display on screen), long press down button for 3 seconds to switch between heating and cooling
2.Power on(power icon not display on screen),long press “M” button for 3 seconds to switch between °C and °F
3.Default States:
Default SET Temperature:20°C
Default Mode:Heating
Technical parameters
Anbang Technical Data
Operating Temperature | -10°C ~ 70°C |
Temperature Control range | 5°C (40°F) ~30°C(85°F) |
Precision | ±0.5°C |
Connection | 230 V ~ 50/60Hz |
Load (Max) | 16A 4KW – Resistive load;2A 460W – Inductive load |
Measuring period: | 10 S |
Sensor | Interal sensor and external sensor (3meters) |
Features | LCD display |
Heating/cooling function | |
°C and°F displaying switchover | |
Maximum range | 100 meters in open area |
Application | Electric floor heating |
Far infrared heater panel | |
Socket Type | EU,UK,Italy,France,USA and so on sockets type |
Screen display
Important safety precautions
1) Do not use an extension lead.
2) Do not plug any device performing mechanical movement directly into the temperature controller.
3) Fan or other appliances with exposed elements should not be left unattended,and it is recommended that these types of appliances are not connected to the temperature controller.
4) Do not insert needles or any other metal objects into mains outlet.
5) Avoid moisture,extreme temperatures, shock and vibration.
6) Used indoors only and do not be exposed in Sunshine.
7) Recommended ambient temperature is 10ºC~ 40ºC
8) Do not open the temperature controller. Repaired must be performed by authorized service personnel only.
9) To clean casing and display use a soft cloth. Do not use chemical or scouring agents. Do not submerge in water.
10) Keep device out of the reach of children.
11) Recharge the battery when the LCD displays “LO”.