| Motor Type: | DC Motor |
|---|---|
| Model Number: | LE3U 14MR |
| Brand Name: | LOLLETTE |
| Input : | 8 |
| Output: | 6 relay |
| AD: | 6 |
| DA: | 2 |
| AD0-AD2: | 0-10V |
| AD3-AD5: | 0-20MA |
| Unit Type: | piece |
| Package Size: | 12cm x 15cm x 18cm (4.72in x 5.91in x 7.09in) |
| Package Weight: | 0.5kg (1.10lb.) |
Quick Details
Specifications
LE3U 14MR6AD2DA PLC programmable logic controller
Third party Programming Software Description: can be compatible with the programming software Developer7.8 GX or 8.52.8.5 .8.86 Version
8-point input, 6 relay outputs
X0-X5 high-speed input, can be accessed by three AB encoder, the default 12K, optional 100K
6 analog (3channel 0-10v, 3channel 0-20mA) 2 channel 0-10v analog output
Power-down to maintain, can be set free
DC 24V power supply
3-way AB input
Support for 16-bit encryption,
Supports three kinds of interrupts,
485 communication Support 4 kinds of communication protocols,
Support 1N, 2N, 3U of the instructions,
Power-down to maintain their own set range,
Program 8000 steps,
Download speed 38400,
Floating-point operations,
HMI,
Scan 3000 steps 1ms
Note : since the international air does not allow the hair contains flammable and explosive goods, so the unity does not contain the battery delivery, thank you for understanding!
| Input Power |
DC24 |
| Number of steps |
8000 steps; 2 communication ports: 1 RS232 (DB9 serial port is communication port for the FX3u protocol 38400,7,E,1; 1 RS485 (485 selection) communication protocol can be set D8120). |
| X input element |
X0-X27 DC24 input,Low level,X0-5 is a high-speed count input port (the Default is 12K, 100KHZ optional) |
| Y output element |
Y0-Y27 for optimal relay output,relay output current 5A. 4 continuation electric apparatus 1 common end, altogether 3 common ends |
| Analog input |
6 analog input, 12 bit precision, 3 channel analog input 0-10V, 3 channel analog input 0-20MA; read analog RD3A instruction |
| Analog output |
2 analog output, 12 bit precision, output voltage: 0-10V. output analog voltage with WR3A instruction |
| Intermediate relay |
M0-M3071, power-down save range can be set M0-M1023, the default M500-M1023 |
| Step point |
S0-1023, power-down save range can be set S0-S1023, the default S500-S9999 |
| 100Ms timer |
T0-T199 Accumulated power-down saving T184-T199 |
| 10Ms timer |
T200-T249 Accumulated power-down saving T246-T249 |
| 1Ms timer |
T250-T383, where T250-255 is the cumulative type |
| 16-bit counter |
C0-C199, power-down save C100-C199 |
| 32-bit counter |
C200-C219, save the power-down C220-C234 |
| 32-bit high-speed counter |
C235-255; C235-C240 for the single-phase counter, not multiplier; C241-240 for the single-phase calculator, 2 octave; C2470249 for the dual-phase counter, not multiplier; C250-252 for dual-phase counter, ; C253-C255 for the dual-phase counter, 4 octave |
| Register D |
D0-D7999, power-down save the range can be set D0-7999 |
| Indirect addressing pointer V, Z |
V0-7, Z0-7 |
| P The subroutine jump number |
P0-63 |
| I interrupt |
X0-5 external interrupt, timer interrupt (1MS unit) counter interrupt |
| Special M components |
M8000 run-time normally closed, M8002 power pulse, M8011 is 10Ms pulse, |