Product Main

Quick Details

Motor Type: DC Motor
Unit Type: piece
Package Size: 15cm x 15cm x 10cm (5.91in x 5.91in x 3.94in)
Package Weight: 0.15kg (0.33lb.)

Specifications

Related products
Descriptions:

1: Model: YYH-2 can control DC motor forward and reversing, speed, timing, spacing and other functions into one, to meet the needs of more applications.
 
2: Product Features: This product MOS transistor H-bridge circuit, performance, input and output opto isolated ,, as low as 0.01 seconds frequent switching, no noise, speed can be 10, well ahead of the relay contact control, relay contact point has life limit, and there was a noise, poor sensitivity, frequent contacts easily burn blocking relay contacts
 
3: Low power consumption: about 15ma, can be set to low-power mode, standby current of less than 10ma
 
4: Input voltage range and controllable power: Input voltage: DC4.2V ~ 28V, output can be controlled within the motor current 7A
 
5: time: 0.01 seconds to 99 hours at any time adjustable
 
6: Speed range: a total of 10 files, the speed from 0% to 100% at any speed
 
7: Wiring Port Description:
 
IN1, IN2: signal input (active low, negative trigger sensors can be connected NPN)
 
 
DC-:  power negative input (DC 4.2V ~ 28V wide voltage)
 
DC +: power supply positive input
 
M +, M-:  output termination connect motor, regardless of the positive and negative level
 
8: Other Frequently Asked Questions: A: All settings option to automatically save the set of non-volatile content
 
                  B: But frequent on-off, performance is better than relays, than the average life expectancy is longer electromagnetic relay
 
9: Feature List:
 
P-1: the signal, forward or reverse to set the time automatically stop
 
F-0: to the signal 1, is to set the time automatically stopped again ,during the delay trigger is invalid
 
To signal 2, reversed to set the time automatically stopped again ,during the delay trigger is invalid
 
F-1: to the signal 1 , forward to set the time automatically stopped again, during the delay time again
 
    To signal 2, reversed to set the time automatically stopped again ,during the delay time again
 
F-2: 1 to the signal, forward to set the time automatically stop, once again trigger a reset during the delay, the motor stops immediately
 
    To signal 2, reversed to set the time automatically stop, once again trigger a reset during the delay, the motor stops immediately
 
P-2: with automatic forward and reversing with stop time, the reset signal 2
 
   F-0: Auto power on an infinite loop: forward, stop, reverse, stop .... as forward reversing time, stop time, as
 
   F-1: 1 signal to start an infinite loop: forward, stop, reverse, stop .... as forward reversing time, stop time, as
 
   F-2: 1 initiates a signal: forward, stop, reverse, stop, do not cycle, forward and reversing the same time, stop time, as
 
P-3: automatic reversing without stopping time, the reset signal 2
 
    F-0: power on automatically start an infinite loop: forward, reverse .... which may not be the same as reversing time
 
    F-1: 1 signal to start an infinite loop: forward, reverse .... which may not be the same as reversing time
 
    F-2: 1 initiates a signal: forward, reverse without circulation which the forward reversing time can be different
 
P-4: Limit function
 
    F-0: power-forward encountered signal 1 (limit), and immediately reversed, encounter signal 2 (limit), immediately forward the cycle
 
    F-1: power-forward encountered signal 1 (limit), stop for some time auto reverse, met signal 2 (limit), automatic stop for some time forward, recycling
 
 
    F-2: power-forward encountered signal 1 (limit), stop for some time auto reverse, met signal 2 (limit), automatic stop for some time forward, not circulated
 
10: Brief description :( key set during the automatic timing, invalid button is pressed, to prevent interference or misuse)
 
 
Mode: Press: After mode selection key P- * choose well, press the enter function K2
 
Short press: Set the time, set the order of: a first set of time, the second set time, set the time unit
 
+: When the display flashes: time plus or adjusting the first set of time units
 
   Display not flashing: small function selection key F- *, after a good choice, press K3 into the function
 
-: The display flashes: Save time or adjusting the second group unit of time
 
   Display not flashing: You can permanently turn on or off the display to reduce power consumption
 
NOTE: Time Unit Description:
 
The middle two o'clock flash (about 0.2 seconds), displayed value in seconds: 0.01 seconds
 
Two middle slow flash (approximately 2 seconds), displayed value in hours: minutes
 
Two intermediate normal flash (approximately 1 second) to display the value in minutes: seconds
 
Speed +: Press to accelerate a file, a total of 10 stalls, the speed from 0% to 100% at any speed
 
Speed -: Press a gear reducer, a total of 10 stalls, the speed from 0% to 100% at any speed
 
 
 
Packaging
1pcs*  5V 12V 24V DC Motor Controller  For Forward Reverse Control Automatic / Speed Control / Timing / Delay  / Limit H bridge Module with case Hope_01
1 2 3 4 5 6 Hope_02 Hope_03 Hope_04