Model Number: | DM432C |
---|---|
Motor Type: | Stepper Motor |
Unit Type: | piece |
Package Size: | 15cm x 10cm x 8cm (5.91in x 3.94in x 3.15in) |
Package Weight: | 0.45kg (0.99lb.) |
Quick Details
Specifications
Drive function |
Operating instructions |
Micro-step subdivision set |
SW5 - SW8 Four dip switches to set the micro step drive subdivision, the total 15 Micro-step breakdown. While user micro-step segmentation should first stop the drive operation. Micro-step creation of a subdivision, please drive layout instructions. |
Output current setting |
SW1 - SW3 Three dip switches to set the drive output current, the output current total 8 Document. Specific output current setting, please drive layout instructions. |
Automatic half flow features |
Users can SW4 To set the drive's automatic half stream. Off half the quiescent current is set to dynamic current,on quiescent current and dynamic currents of the same. General purpose should be in SW4 set to off, Reduce the heating of the motor and drive, and increased reliability. Pulse train stopped after about 0.4 seconds or so current is automatically reduced to about half (the actual value of 60 %), Reduce the heat theory to 36 %. |
Signal interface |
PUL + And PUL -To control the pulse signal positive end and negative end; DIR + And DIR -Direction signal positive end and negative end; ENA + And ENA -Enable signal positive end and a negative end. |
Electrical interface |
A + And A -Stepping Motor A The positive and negative ends of the winding; B + And B -Stepping Motor B The positive and negative ends of the winding. Dang , andb two-phase winding when replaced, motor direction can be reversed. |
Power interface |
DC power supply operating voltage range is recommended for 18 - 40VDC , Power is greater than the 100W . |
LEDs |
Drive has two red and green indicator lights. Green light for the power led, when the drive is powered on green always; the Red fault led, when over voltage, over current fault, the fault lights stay lit. After fault elimination, red light off. When a drive fails, it can only power on again and again to clear the fault. |
Installation instructions |
Drive size: 116×69.2×26.5mm Installation hole distance 109mm . Both horizontal and vertical installation vertical installation is recommended. When installed, should be attached to the metal cabinet in order to facilitate heat dissipation. |
Micro-step segmentation set
|
SW5 |
SW6 |
SW7 |
SW8 |
Default |
on |
on |
on |
on |
400 |
off |
on |
on |
on |
800 |
on |
off |
on |
on |
1600 |
off |
off |
on |
on |
3200 |
on |
on |
off |
on |
6400 |
off |
on |
off |
on |
12800 |
on |
off |
off |
on |
25600 |
off |
off |
off |
on |
51200 |
on |
on |
on |
off |
1000 |
off |
on |
on |
off |
2000 |
on |
off |
on |
off |
4000 |
off |
off |
on |
off |
5000 |
on |
on |
off |
off |
8000 |
off |
on |
off |
off |
10000 |
on |
off |
off |
off |
20000 |
off |
off |
off |
off |