Quick Details

Motor Type: AC Motor
Model Number: DSE5220
size: 24*17*5.5 cm
Biaya gagal/eksitasi kisaran: 0 v sampai 35 v
Frekuensi input magnetik: 10,000 hz (max)
usage: controlador de gerador de vento
Color: Black
Unit Type: piece
Package Size: 15cm x 15cm x 10cm (5.91in x 5.91in x 3.94in)
Package Weight: 1.5kg (3.31lb.)

Specifications

DSE5220 generator controller high quality diesel genset generator engine control unit

 

Introduction

The DSE5220 is an Automatic Mains Failure Control Module designed to automatically start and stop diesel
and gas generating sets that include non electronic engines.  The module also provides excellent engine monitoring and protection features.
 
The module has the ability to monitor under speed, over speed, charge failure, emergency stop,
low oil pressure, high engine temperature, fail to start, fail to stop, under/over generator volts,
over current, under/over generator frequency, low/high DC battery volts, low fuel alarm and loss of
the speed sensing signal. The module displays fault conditions on the LCD display and via the LED
indicators on the front.
 
The DSE5220 also has the ability to monitor a mains (utility) supply.  Upon detection of a mains (utility)
failure the module automatically starts the generating set. Once the mains (utility) power has been
restored it instructs the generating set to stop.

 

Technical data

DC Supply 8 to 35 V Continuous
Max. Operating Current 425mA at 12 V & 215mA at 24 V
Max. Standby Current 250 mA at 12 V & 125 mA at 24 V.
Alternator Input Range 75V(ph-N) to 277V(ph-N) AC (+20%)
Alternator Input Frequency 50 - 60 Hz at rated engine speed (Minimum: 15V AC Ph-N)
Magnetic Pick-up Voltage Input Range +/- 0.5 V to 70 V Peak
Magnetic Input Frequency 10,000 Hz(max)
Start Relay Output 16 Amp DC at supply voltage
Fuel Relay Output 16 Amp DC at supply voltage
Auxiliary Relay Outputs 5 Amp DC at supply voltage
Dimensions 240mm x 172mm x 57mm(9½' x 6¾' x 2¼' )
Charge Fail / Excitation Range 0 V to 35 V
Operating Temperature Range -30 to +70°C
Mains Sensing Input Range 15V(ph-N) to 277V(ph-N) AC (+20%)
Mains Sensing Input Frequency 50 - 60 Hz
Generator loading Relay Output 8 Amp AC 250V
Mains loading Relay Output

8 Amp AC 250V