Product Main

Quick Details

Motor Type: AC Motor
Model Number: JKL5C
Size: 14*14*14cm
PCB: Relay control Signal
Power supply: Power Transformer 230V~400V
Type: Reactive power Auto Compensation Controller
Power Sensor: CT Type
power factor capacity: 0.00~1.00
Function: Harmonic power factor
Display: LED
Over Voltage Setting: 230V~500V
Control Step: 8 step
Unit Type: piece
Package Size: 15cm x 15cm x 15cm (5.91in x 5.91in x 5.91in)
Package Weight: 1.8kg (3.97lb.)

Specifications

JKL5C power factor regulator compensation controller for power factor capacitor 8step 380v

The power factor approve state of user

To improve the utilization efficiency of electric transformer

Reducing line loss

To improve the voltage quality of power supply

 

Specification

Item  Name   JKL5C power factor controller 
1 LED/LCD Display will show  
a.three-phase voltage,current, active power, reactive 
b.power factor and power network frequency, control parameter
2 Strong anti-interference ability can resist 2kv impulse test ,keep data 
3 You can revise control data sheet ,it will save data no power 
4 Auto analysis phase function 
5 Current get signal resistor less than 0.05Ω
6 Over voltage ,under voltage lack phase protection function 
7 Input way: static ,Dynamic ,compound 
8 Rated voltage AC 220V±10%  AC 380V±10%
9  Rated current AC 0-5A
10 Rated frequency 50Hz±5%
11 Sensitivity 100mA
12 COS φ Preset  0.80-0.99; step length 0.01; Factory preset 0.98 input and cutoff time
13 Input Delay dynamic state 100ms-30S; Static state 1-250S;Factory preset dynamic state 5S; 
static state 30S.
14 Over-voltage protection 230-260V; step length 1V; Return difference 6V  reset 240V
15 Under-voltage protection 180V;return difference 6V
16 Auto Discriminating Phase ON/OFF; factory preset ON(Auto discriminating ON)
17 Reactive threshold OFF-4-100kvar; factory preset OFF (reactive threshold inefficiency)
18 CT variation 50/5A-3000/5A; step length 1; factory preset 500/5A
19 Capacitance capacity 0-99kvar factor preset of each branch 10kvar
20 Contact capacity dynamic state output of each branch DC12V×50mA
Static state output of each branch 380V×7A/200V×5A
21 size 113*113   138*138

 

 

Advantage

1.20 years global leading profession manufacture of energy meter 

2.the precision of measurement

The current identification: the controller can judge the sampling current polarity and automatic conversion.

3.the display of choice

4.parameter setting function

5.protection function

6.control strategy, capacitors

7.output circuit design 

8.Fast delivery : you will get the order when you need it 

9.OEM is warmly welcome 

10.Convenient : 45 minutes to wenzhou airport 

 

Function 

1.Control signal: comprehensive control by using the power factor and reactive current of two physical quantities

2.Step :step number selected by the user

3.Data storage: after the loss of electricity parameter settings will not be lost, data save permanently

4.Adaptability: automatically adapt to the distribution system of different parameters of the controller, does not need to provide the transformation ratio of current transformer and capacitor compensation capacity

5.Overvoltage protection: the voltage is higher than the set value quickly over voltage, gradual resection capacitors have been put

6.Strong anti-interference: unique design, crash, indiscriminately, indiscriminate cutting phenomenon can not occur in operation

7.Switching shocks: can prevent the small current load and over voltage critical values appear repeated switching

8.High sensitivity: compensator can work normally in the input signal when the current is 0.10A

9.Display error: input signal power of current 0.10A to 5A changes due tonumerical error measurement showed minimal

10.The current identification: the controller can judge the sampling current polarity and automatic conversion

5