Conductor Material: | Copper |
---|---|
Application: | Power Station |
Type: | Low Voltage |
Insulation Material: | XLPE |
Brand Name: | ECHU/OEM |
Model Number: | H1Z2Z2-K |
Place of Origin: | China (Mainland) |
TYPE: | H1Z2Z2-K 4.0MM2 |
Conductor: | Class 5 flexible tinned copper conductor |
Quick Details
Specifications
APPLICATION
Updated harmonised (H1Z2Z2-K) European standard solar cable intended for the interconnection within photovoltaic systems such as solar panel arrays.
Suitable for fixed installations, internal and external, within conduit or systems, but
Not direct burial applications. Our solar cable is ozone-resistant
According to BS EN 50396, UV resistant according to HD 605/
A1, and is tested for durability according to EN 60216. for
Installations where fire, smoke emissions and toxic fumes create
A potential risk to life and equipment.
Conductor
Class 5 flexible tinned copper conductor
Insulation
Halogen-free cross-linked compound
Sheath
Halogen-free cross-linked,flame retardant compound
Voltage Rating
(Uo/U)
AC: 600/1000V
DC: 900/1800V
Temperature Rating
Fixed: -40C to +90C
Minimum Bending Radius
Fixed: 4 x overall diameter
Flexed: 5 x overall diameter
Maximum Voltage
(Umax)
1.8kV DC (conductor/conductor, non earthed system, circuit not
under load)
Maximum Conductor Temperature
+120C (for 20000h)
Test Voltage
6.5kV AC according to BS EN 50395
Sheath Colour
Black or Red
<
Updated harmonised (H1Z2Z2-K) European standard solar cable intended for the interconnection within photovoltaic systems such as solar panel arrays.
Suitable for fixed installations, internal and external, within conduit or systems, but
Not direct burial applications. Our solar cable is ozone-resistant
According to BS EN 50396, UV resistant according to HD 605/
A1, and is tested for durability according to EN 60216. for
Installations where fire, smoke emissions and toxic fumes create
A potential risk to life and equipment.
Conductor
Class 5 flexible tinned copper conductor
Insulation
Halogen-free cross-linked compound
Sheath
Halogen-free cross-linked,flame retardant compound
Voltage Rating
(Uo/U)
AC: 600/1000V
DC: 900/1800V
Temperature Rating
Fixed: -40C to +90C
Minimum Bending Radius
Fixed: 4 x overall diameter
Flexed: 5 x overall diameter
Maximum Voltage
(Umax)
1.8kV DC (conductor/conductor, non earthed system, circuit not
under load)
Maximum Conductor Temperature
+120C (for 20000h)
Test Voltage
6.5kV AC according to BS EN 50395
Sheath Colour
Black or Red
<
TYPE | SPEC. mm2 | Weight | Dia. mm |
H1Z2Z2-K | 1.5 | 43.5 | 5.4 |
H1Z2Z2-K | 2.5 | 57.2 | 5.9 |
H1Z2Z2-K | 4 | 77.5 | 6.6 |
H1Z2Z2-K | 6 | 104.0 | 7.4 |
H1Z2Z2-K | 10 | 153.6 | 8.8 |
H1Z2Z2-K | 16 | 217.3 | 10.1 |
H1Z2Z2-K | 25 | 336.2 | 12.5 |
H1Z2Z2-K | 35 | 445.8 | 14.0 |
1, Conductor: Copper Acc.IEC 60228+EN60228,VDE0295 CLASS5 ,Tinned, Fine Stranded Copper Conductor | |||
2, Insulation:XLPE Resistant to UV, ozone and Hydrolysis. XLPO Sheath UL4703 | |||
3, Sheath: XLPE Resistant to UV, ozone and Hydrolysis. XLPO Sheath UL4703 | |||
4.Type: Solar PV cable H1Z2Z2-K,TUV cert. | |||
5.Rated Voltage: 0.6kV/1KV | |||
6.Temperature Range: -40+90 dry or wet | |||
7.20000 hour Max.Temperature at Conductor can be 120. |