Product Main

Quick Details

Usage: Universal Testing Machine
Power: Electronic
Brand Name: PONOVO
Warranty: 12 months
weight: 350KG-450KG
Model Number: PAV3000/5000/10000/15000/20000/30000
Place of Origin: China (Mainland)
Color: black and white
Output frequency range: 0-5000Hz

Specifications

Ponovo PAV Series 4-Quadrant Power Amplifier for Real Time Digital Simulation


Best Application Assistant for Digital Simulator System



PONOVO's PAV series of 4-quadrant simulation power amplifiers is based on linear power amplifier technology, and integrated advanced technical performance with rich functions. It is widely used by institutions in industries of power, new energy, aerospace, railway transportation, mining, petrochemical etc. It is also the ideal R&D device for wind power, PV, electric car, large power charging device, aerospace power system, marine power system, energy distribution and micro grid etc.
It can be directly connected to popular simulation platforms including RTDS, OPAL-RT, NI, Typhoon etc., supporting not only analog input communication, but also digital interface communication via AURORA protocol.
It can work as both source mode to output power and also sink power mode to conduct power absorption.
PAV Series 4Quadrant Power Amplifier for Real Time Digital Simulation


Models:
PAV3000 4-Quadrant Power Amplifier
PAV5000 4-Quadrant Power Amplifier
PAV10000 4-Quadrant Power Amplifier
PAV15000 4-Quadrant Power Amplifier
PAV20000 4-Quadrant Power Amplifier
PAV30000 4-Quadrant Power Amplifier
PIV270 Portable 4-Quadrant Power Amplifier
Power Amplifier DIA-01 Aurora Digital Module for Simulator Application
PAL Programmable AC Load Unit
PDL Programmable DC Load Unit
PADS Programmable AC&DC Power Supply Unit



Main Features:

  • Extremely low harmonic distortion - even under very non-linear load conditions
  • Very fast slew rate: >50V/μs
  • Short Input/Output delay: <10μs
  • Wide frequency range: DC~5kHz
  • High input impedance
  • High output precision
  • High accuracy output
  • Special port for power interactive simulation in 4-quadrant
  • Supports optical digital communication with PHIL interface via AURORA protocol
  • Dual-gain to work smoothly with different simulations
  • Measurement, monitor and protection functions
  • High long-term overload characteristic (up to 1 hour)
  • High short-term overload characteristic (for 5-10 min)


Applications:


the distributed energy system such as photovoltaic power generation,Wind generation, energy storage battery and fuel
Cell system etc
the microgrid
the electromobile and charge unit
the energy storage
Railway transportation
the aerospace
the electric system detection
the hybrid simulation in power system
HVDC
FACTS
HVDC and HVAC connection
Dynamic load analysis on AC, etc.



Application Areas:


Distributed energy systems such as photovoltaic power generation, wind generation, energy storage battery and fuel cell system etc. Electric system detection
Microgrid Hybrid simulation in power systems
Electromobile and charge units HVDC
Energy storage FACTS
Railway transportation HVDC and HVAC connection
Aerospace Dynamic load analysis on AC, etc.


Specifications: PAV3000 / PAV5000 / PAV10000

Model PAV3000 PAV5000 PAV10000
Nominal Voltage


AC 270V (135V optional) 270V (135V optional) 270V (135V optional)
DC ±382V (±191V optional) ±382V (±191V optional) ±382V (±191V optional)
Line Regulation 1.510-4 / 10V 1.510-4 / 10V 1.510-4 / 10V
Gain 25V/V; 40V/V (optional) 25V/V; 40V/V (optional) 25V/V; 40V/V (optional)
Gain Stability (const load & Temp.) ±0.1% / 5min ±0.1% / 5min ±0.1% / 5min
Frequency Range


Bandwidth range DC~5kHz (-3dB) DC~5kHz (-3dB) DC~5kHz (-3dB)
Small signal (3%) DC~50kHz (-3dB) DC~50kHz (-3dB) DC~50kHz (-3dB)
Harmonic Distortion


45~450Hz (Typ. / Max.) 0.05% / 0.2% 0.05% / 0.2% 0.1% / 1%
450~5kHz 0.6% typ., 1% guar. 0.6% typ., 1% guar. 0.6% typ., 1% guar.
Input


Signal Range (Analog Signal) 0~±16V (25V/V) (optional)
0~±10V (40V/V)
0~±16V (25V/V) (optional)
0~±10V (40V/V)
0~±16V (25V/V) (optional)
0~±10V (40V/V)
Digital Signal Interface Communication interface with fiber optic ports, supporting AURORA protocol Communication interface with fiber optic ports, supporting AURORA protocol Communication interface with fiber optic ports, supporting AURORA protocol
Impedance 10kΩ 10kΩ 10kΩ
Input/Output Delay 10μs 10μs 10μs
Power AC (Nominal Voltage 270V) 3kVA 5kVA 10kVA
Power DC (Nominal Voltage ± 382V) 3kW 5kW 10kW
Long-time Overload (1 hour) 4.5kVA 7.5kVA 15kVA
Max. Short-time Power 6kVA 10kVA 20kVA
Max. Sink Power 30% rated output power 30% rated output power 30% rated output power
Measurement Range


Voltage 0~300V 0~300V 0~300V
Current 0~24A 0~40A 0~80A
Accuracy of Voltage Measurement 0.5% RG 0.5% RG 0.5% RG
Accuracy of Current Measurement 0.5% RG 0.5% RG 0.5% RG
Accuracy of Power Measurement 0.5% RG 0.5% RG 0.5% RG
Protection Overload / Short-circuit / Overheat Overload / Short-circuit / Overheat Overload / Short-circuit / Overheat
Digital Monitoring Unit (optional)


Analog output 0~±10V (±16 optional) 0~±10V (±16 optional) 0~±10V (±16 optional)
Signal accuracy AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V
Frequency output range 0~5000Hz 0~5000Hz 0~5000Hz
Frequency accuracy Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz
Selectable waveforms (optional) DC, sine, square, triangle, ramp, arbitrary DC, sine, square, triangle, ramp, arbitrary DC, sine, square, triangle, ramp, arbitrary
Power supply 3 phase 380V/208V±10%,
50/60±5Hz
3 phase 380V/208V±10%,
50/60±5Hz
3 phase 380V/208V±10%,
50/60±5Hz
Power protection Short-circuit,
Defaut-phase alarm
Short-circuit,
Defaut-phase alarm
Short-circuit,
Defaut-phase alarm
Dimensions


Cabinet (W D H) 650mm 900mm 2100mm, 43U 650mm 900mm 2100mm, 43U 650mm 900mm 2100mm, 43U
Power amplifier unit 19'', 5U 19'', 5U 19'', 11U
Digital monitor unit 19'', 4U 19'', 4U 19'', 4U
Power supply unit 19'', 12U 19'', 12U 19'', 12U
Weight 450kg 450kg 3 450kg

*Note: the default frequency is 50Hz/60Hz except for the explicitly indicated frequency.
Specifications: PAV15000 / PAV20000 / PAV30000

Model PAV15000 PAV20000 PAV30000
Nominal Voltage


AC 270V (135V optional) 270V (135V optional) 270V (135V optional)
DC ±382V (±191V optional) ±382V (±191V optional) ±382V (±191V optional)
Line Regulation 1.510-4 / 10V 1.510-4 / 10V 1.510-4 / 10V
Gain 25V/V; 40V/V (optional) 25V/V; 40V/V (Could be customized set, optionally) 25V/V; 40V/V (Could be customized set, optionally)
Gain Stability (const load & Temp.) ±0.1% / 5min ±0.1% / 5min ±0.1% / 5min
Frequency Range


Bandwidth range DC~5kHz (-3dB) DC~5kHz (-3dB) DC~5kHz (-3dB)
Small signal (3%) DC~50kHz (-3dB) DC~40kHz (-3dB) DC~40kHz (-3dB)
Harmonic Distortion


45~450Hz (Typ. / Max.) 0.1% / 1% 0.5% / 1.5% 0.5% / 1.5%
450~5kHz 1% typ., 2% guar. 1% typ., 2% guar. 1% typ., 2% guar.
Input


Signal Range (Analog Signal) 0~±16V (25V/V) (optional)
0~±10V (40V/V)
0~±16V (25V/V) (optional)
0~±10V (40V/V)
0~±16V (25V/V) (optional)
0~±10V (40V/V)
Digital Signal Interface Communication interface with fiber optic ports, supporting AURORA protocol Communication interface with fiber optic ports, supporting AURORA protocol Communication interface with fiber optic ports, supporting AURORA protocol
Impedance 10kΩ 10kΩ 10kΩ
Input/Output Delay 10μs 10μs 10μs
Power AC (Nominal Voltage 270V) 15kVA 20kVA 30kVA
Power DC (Nominal Voltage ± 382V) 15kW 20kW 30kW
Long-time Overload (1 hour) 22.5kVA 30kVA 45kVA
Max. Short-time Power 30kVA 40kVA 60kVA
Max. Sink Power 30% rated output power 30% rated output power 30% rated output power
Measurement Range


Voltage 0~300V 0~300V 0~300V
Current 0~120A 0~200A 0~300A
Accuracy of Voltage Measurement 0.5% RG 0.5% RG 0.5% RG
Accuracy of Current Measurement 0.5% RG 0.5% RG 0.5% RG
Accuracy of Power Measurement 0.5% RG 0.5% RG 0.5% RG
Protection Overload / Short-circuit / Overheat Overload / Short-circuit / Overheat Overload / Short-circuit / Overheat
Digital Monitoring Unit (optional)


Analog output 0~±10V (±16 optional) 0~±10V (±16 optional) 0~±10V (±16 optional)
Signal accuracy AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V
AC: 0.03% RG + 0.1% @ 0.5~6.75V
0.1% RG + 0.5% @ 0.1~0.5V
DC: 0.03% RG + 0.1% @ 0.5~9.55V
0.1% RG + 0.5% @ 0.1~0.5V
Frequency output range 0~5000Hz 0~5000Hz 0~5000Hz
Frequency accuracy Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz
Accuracy (DC):
15 Hz~450Hz, ±0.02 Hz
450Hz~2000Hz, ±0.1Hz
2000Hz~5000Hz, ±0.15Hz
Selectable waveforms (optional) DC, sine, square, triangle, ramp, arbitrary DC, sine, square, triangle, ramp, arbitrary DC, sine, square, triangle, ramp, arbitrary
Power supply 3 phase 380V/208V±10%,
50/60±5Hz
3 phase 380V/208V±10%,
50/60±5Hz
3 phase 380V/208V±10%,
50/60±5Hz
Power protection Short-circuit,
Defaut-phase alarm
Short-circuit,
Defaut-phase alarm
Short-circuit,
Defaut-phase alarm
Dimensions


Cabinet (W D H) 650mm 900mm 2100mm, 43U on request on request
Power amplifier unit 19'', 17U on request on request
Digital monitor unit 19'', 4U on request on request
Power supply unit 19'', 12U on request on request
Weight 3 450kg, 1 280kg on request on request

*Note: the default frequency is 50Hz/60Hz except for the explicitly indicated frequency

PAV Series 4Quadrant Power Amplifier for Real Time Digital Simulation