Insulation Material: | ROHS PVC |
---|---|
Conductor Material: | bare copper or tinned copper |
Application: | For internal wiring of electronic and electrical equipment |
Type: | Insulated |
Brand Name: | ECHU |
Conductor Type: | Stranded |
Model Number: | UL1007 18AWG |
Place of Origin: | China (Mainland) |
TYPE: | UL1007 |
Standards: | UL758 & UL1581 |
Voltage: | 300V |
Temp.: | 80 Degree |
Quick Details
Specifications
Description:
Rated temperature: 80
Rated voltage: 300V
Reference stranded: UL subject 758 & UL 1581/CSA C22.2 NO.210.05.
Tinned or bare, stranded or solid copper conductor
Insulation: PVC
Uniform insulation thickness to ensure easy stripping and cutting
Passed Ul VW-1 flame test.
Application
for internal wiring of electronic and electrical equipment
UL certificate No.: E312831
Can be substituted by UL 10982 &UL3385.
TYPE | Conductor | Spec. AWG | Conductor No. | Conductor Dia. | Weight KG/KM | Insulation Thickness. mm | Insulation External Dia.Mm | ||
Lowst | upst | ||||||||
UL1007 | Bare Copper | 26 | 7 | 0.16 | 3.55 | 0.40 | 1.3 | 1.50 | |
UL1007 | Bare Copper | 24 | 11 | 0.16 | 4.58 | 0.40 | 1.5 | 1.70 | |
UL1007 | Bare Copper | 22 | 17 | 0.16 | 6.03 | 0.40 | 1.6 | 1.80 | |
UL1007 | Bare Copper | 20 | 26 | 0.16 | 8.09 | 0.40 | 1.8 | 2.00 | |
UL1007 | Bare Copper | 18 | 41 | 0.16 | 11.38 | 0.40 | 2.1 | 2.30 | |
UL1007 | Bare Copper | 16 | 26 | 0.254 | 17.18 | 0.40 | 2.4 | 2.60 | |
TYPE | Conductor | Spec. AWG | Conductor No. | Conductor Dia. | Weight KG/KM | Insulation Thickness. mm | Insulation External Dia.Mm | ||
Lowst | upst | ||||||||
UL1007 | Tinned Copper | 26 | 7 | 0.16 | 3.55 | 0.4 | 1.3 | 1.50 | |
UL1007 | Tinned Copper | 24 | 11 | 0.16 | 4.58 | 0.4 | 1.5 | 1.70 | |
UL1007 | Tinned Copper | 22 | 17 | 0.16 | 6.03 | 0.4 | 1.6 | 1.80 | |
UL1007 | Tinned Copper | 20 | 26 | 0.16 | 8.09 | 0.4 | 1.8 | 2.00 | |
UL1007 | Tinned Copper | 18 | 41 | 0.16 | 11.38 | 0.4 | 2.1 | 2.30 | |
UL1007 | Tinned Copper | 16 | 27 | 0.25 | 17.18 | 0.4 | 2.4 | 2.60 |