Product Main

Quick Details

Brand Name: Kanglida or OEM
Type: First-Aid Devices
Color: White
Material: fiberglass
Certificate: CE,ISO,FDA
Place of Origin: China (Mainland)
Model Number: KSF312
SIZE: 7.5X30cm

Specifications

Medical Consumables Ortopedic Fiberglass Splint

Orthopedic Casting Splint

 

Klida orthopedic splint is composed by manifold layers of orthopedic casting tapes and specially non woven fabrics. It is characterized by better viscosity, fast drying time, high rigidness after dying and light weight. Due to better bio compatibility, polyurethane is widely used in medical places. Animal study and acute and chronic toxicity test have proved that medical polyurethane was non-toxic and no-induced distortion, no local irritation and no allergic reaction.

 

Specification

 

A.Fiberglass Material

model

size

Packing

KSF 312

7.5CM X 30 CM

20Bags *6boxes/ctn

KSF 335

7.5CM X 90 CM

10 bags *6boxes/ctn

KSF 415

10.0CM X 40 CM

15 bags *6boxes/ctn

KSF 430

10.0CM X 75 CM

10 bags *6boxes/ctn

KSF 530

12.5CM X 75 CM

10 bags *6boxes/ctn

KSF 545

12.5CM X115 CM

5 bags *6boxes/ctn

KSF 630

15.0CM X 75 CM

10 bags *6boxes/ctn

KSF 645

15.0CM X 115 CM

5 bags *6boxes/ctn

 

B.Polyester Material

model

size

Packing

KSP312

7.5CM X 30 CM

20Bags *6boxes/ctn

KSP 335

7.5CM X 90 CM

10 bags *6boxes/ctn

KSP 415

10.0CM X 40 CM

15 bags *6boxes/ctn

KSP 430

10.0CM X 75 CM

10 bags *6boxes/ctn

KSP 530

12.5CM X 75 CM

10 bags *6boxes/ctn

KSP 545

12.5CM X115 CM

5 bags *6boxes/ctn

KSP630

15.0CM X 75 CM

10 bags *6boxes/ctn

KSP 645

15.0CM X 115 CM

5 bags *6boxes/ctn


Package

1pc/bag,5bags/box,6boxes/carton

1pc/bag,10bags/box,6boxes/carton

1pc/bag,15bags/box,6boxes/carton

1pc/bag,20bags/box,6boxes/carton

how to use splint

1) Select proper specification according to the surgery position

2) Put the pad (cotton coil or cotton slipcover) on the surgery position.

3) Immerse the roll in room temperature water(21-24C) for 4-6 seconds and squeeze it 2-3 times firmly. If the water warmer than 21-24C shortens the immersing time, while cooler than 21-24C water lengthens the time.

4)Take the splint out and press out excrescent water;Absorb water drip of the splint surface with towel.

5) Put the splint on the fixed position, molding it according to need. Mold it in 3-5 minutes after immersing in water because after that time it will concretion. Allow about 10 minutes for sufficient concretion and let patients not move during this time. It could bear electric weight after 20 minutes.

6) Fix the splint with gauze bandage or elastic bandage after concretion.