| Main Circuit Rating Current: | 600 |
|---|---|
| Main Circuit Rating Voltage: | 48 |
| Phase: | 0 |
| Brand Name: | Jinquan |
| Number of Pole: | |
| Model Number: | 600H(B)/48-48BW |
| Place of Origin: | China (Mainland) |
| Rated coil voltage: | Ue=48V |
| Maximum coil voltage: | 57.6V |
| Mininum coil voltage: | 33.6V |
| Load current: | 600A |
| Coil resistance: | 486 |
| Mechanical life: | 10,0000 times |
| Electric life: | 6000 times |
| Weight: | 0.1kg |
Quick Details
Specifications
1. Product summary
JQ-200D(B)/48-48BW DC contactor has a set of bridge normally opened contactors with load current up to 100A. Accord with GB1408.4-2010/IEC60947-4-1:2009 Ed.3.0.MOD, YD/T585-2010. Suitable for communication power equipment electrical control device.
2. Usage condition
(1) ambient temperature: work: - 40 ~ + 60; storage and transportation: - 40 ~ + 70
(2) relative humidity: 98% at 40
(3) altitude: not more than 2000 meters.
(4) vibration: 10-55hz,
(5) amplitude: 0.35mm
(6) impact: 30m/s2
3. Order mark standard
4. Standard,safty and environmental protection
(1) Comply with GB14048.4-2003 / IEC60947-4-1:2000 low voltage switching equipment and control equipment electromechanical contactor and motor starter standard;
(2) YD/T585-2010 General credit distribution equipment technical conditions.
6. Parameter table(current actual production parameter)
| No. | Requirements | unit | 24 | 48 | 54 |
| 1 | Coil resistance under 20 | 128.5 | 478 | 481 | |
| Coil consuming resistance | W | 4.48 | 4.8 | 6 | |
| Coil resistance error | 8% | 8% | |||
| 2 | Action features | ||||
| Cold suction voltage:4575%Ue | V | 10.815 | 21.629 | 24.3-33.4 | |
| Cold release voltage10%Ue40%Ue | V | 1.87.2 | 3.615 | 5.4-21.6 | |
| Contact pressure drop of main contact | mv | 80 | 80 | 80 |
7.the circuit diagram of the configuration, installation andTerminal
8. General description about company
9. Our mission
10. Packaging and Shipping