Product Main

Quick Details

Main Circuit Rating Current: 200a
Main Circuit Rating Voltage: 48
Phase: 0
Brand Name: Jinquan
Number of Pole:
Model Number: 200D(B)/48-48BW
Place of Origin: China (Mainland)
Rated coil voltage: Ue=48V
Maximum coil voltage: 57.6V
Mininum coil voltage: 38.4V
Load current: 200A
Dielectric strength: 50HZ
Mechanical life: 10,0000 times
Electric life: 1000 times
Weight: 0.5kg

Specifications

DC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil ContactsDC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil ContactsDC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil ContactsDC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil Contacts
1. Product summary

JQ-200D(B)/48-48BW DC contactor has a set of bridge normally opened contactors with load current up to 100A. Accord with GB1408.4-2010/IEC60947-4-1:2009 Ed.3.0.MOD, YD/T585-2010. Suitable for communication power equipment electrical control device.


2. Usage condition

Ambient temperature: work

- 40 ~ + 60;

Storage and transportation: - 40 ~ + 70

Relative humidity 98% at 40
Altitude Not more than 2000 meters
Vibration 10-55hz
Amplitude 0.35mm
Impact 30m/s2


3. Order mark standard

JQ-200D(B)/48-48BW

JQ DC Ccontactor
200 Rated load 200A
D Normally closed
(B) Communication power
B Double coil
48 the contact voltage
48 the contact voltage
W Bending mounting plate


4. Parameter table

Parameter Coil voltage of contact circuit
Voltage range 6-220v
Coil power 5-8w
Normal state Normlly closed
Main rated load current of contact circuit 200A
Rated voltage of contact circuit 6-80v
Sucking time 40ms
Releasing time 30ms
Mechanical life 100000times
Electric life 1000times
Coil resistance 603.6-708.4


5. Standard,safty and environmental protection

(1) Comply with GB14048.4-2003 / IEC60947-4-1:2000 low voltage switching equipment and control equipment electromechanical contactor and motor starter standard;

(2) YD/T585-2010 General credit distribution equipment technical conditions.


6. Verify the tightening torque of mechanical strength of threaded terminal

the thread diameter( mm ) Tightening torque (N.M) Instructions
Meter standard value Diameter range First column: applicable to tighten without prominent headless screw and cannot be used outside the hole edge width is greater than the other screws at the top of the diameter of the screw driver tighten screw;
the first column: suitable for screwdriver screw down the screws and nuts are available;
the first columns: applicable to tighten the screw and nut is not available with a screwdriver.
2.5 2.8 0.2 0.4 0.4
3 2.8<3.0 0.25 0.5 0.5
3.0<3.2 0.3 0.6 0.6
3.5 3.2<3.6 0.4 0.8 0.8
4 3.6<4.1 0.7 1.2 1.2
4.5 4.1<4.7 0.8 1.8 1.8
5 4.7<5.3 0.8 2 2
6 5.3<6.0 1.2 2.5 3
8 6.0<8.0 2.5 3.5 6
10 8.0<10.0 4 10
12 10<12 14
14 12<15 19



7. JQ - 200D(B) / 48 - 48AW current curve

Bridge Double Coil Contacts DC Battery Contactor Available Any Way To Install

8. General description about company

Shenzhen Zhenhua Qunying Electronics CO.,Ltd. Was founded on July 6 , 2012. It's located in in Shenzhen, China's first economic Zone. Our plant was built in 2017. We are Professional manufacturer of Electronics focusing on researching, producing and Selling high(low) pressure Contactor, relay(Magneticretaining relay), shunt Resistor, potentiometer.
DC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil Contacts

9. Our mission
A.  Focusing on quality,

B.  Innovation is our life,

C.   Offering best service to Our customers,

D.   Dedicating all the energy to our business,

E.   Thankfulness to all.

We strictly supervise of products' quality and have been trying to Supply the best service and competitive price to our Customers. In order to Guarantee the interest of customers, we organize a Professional technical team To track industry market and researching suitable Products to meet our Customers' needs.

10. how to order?

(1). Pls let us know what kind of model you want to Order.

(2). Proforma invoice(PI) will be sent to you.

(3). Please check and confirm the PI.

(4). Once we confirmed the order, pls pay it as soon as Possible.

(5). after full payment, all goods will be sent to you in 7-15 days as usual.

(6). OEM/ODM is welcome. Free OEM is for over 5000pcs order.


11. Our advantages
DC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil Contacts


12. Packaging and Shipping

DC Battery Contactor Mechanical Life Up To 300 Thousand Times Bridge Double Coil Contacts