Brand Name: Ainuo
color: blue
Theory: N
Resolution: 2%
Size: N
Model Number: AN9651S(F)AN9651F(F)AN9651B(F)
Place of Origin: China (Mainland)

Specifications


* Comply with CCC,IEC EN,VED,BS,UL,JIS standard Requiements.
* Latest international standard:500VA AC Hipot Capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in Optional leakage current test network MD card,meeting requirements of different Industrial standards Maximum test current of Ground Bond resistance is up to 64A
*6 in 1:AC Hipot,Insulation Resistance,Ground Bond resistance,Leakage Current,Running Power,Low-Voltage Start.
Standby power consumption is optional for AN9651F(F)and AN9651S(F),minimum is low to 0.50w,accuracy is 0.2%
* Simple operation:LED backlit screen Display.Menu operation,Chiense/English langues,socket test fixture.
* Flexible configuration:Built in isolated Transformer,AC frequency conversion power supply,frequency conversion power Supply and industrial PC combiantion

* Satisfy lattest requirements:Follow the production line Developing trends of comprehensive,fast,automation and information.Satisfy Quality management,5s management and refid management requirements.
Stand Electrical Safety Comprehensive tester AN9651SFAN9651FFAN9651BF

Spec.

AC Hipot test

Booster rated output capacity

500VA(5000V/100mA)

Booster maximum short-circuit current

>200mA

Output waveform

Sine wave, <3%(Pure resistance,5000V/1mA),<3%(from empty load to full load)

Output voltage setting

Range

5005000V

Resolution

5V

Accuracy

(3%setting+10V)

Frequency setting

Range

50Hz/60Hz

Accuracy

0.1%setting

Alarming limits setting

Current upper-limit

0.1099.99mA

Current lower-limit

0.0010.00mA

Compensation current setting

Range

0.0010.00mA, automatic testing, compensation can be set to ON/off

Time setting

Range

1999s

Ramp up time range

1100s

Accuracy

(0.1%setting+1count)

Breakdown current alarm

Range

0.1099.99mA

Accuracy

(3%reading+3counts)

Insulation Resistance test

Rated output capacity

2VA(1000V/2mA)

Output voltage regulation

<3%(from no load to full load)

Output voltage ripple

<1%

Output voltage setting

Range

DC 500Vor1000V

Accuracy

(3%setting+3counts)

Alarming limits setting

Resistance upper-limit range

0.099.9 M,1002000M(If upper-limit is set to 0, it will not make adjudgment for upper Limit)

Resistance lower-limit range

0.399.9 M, 1002000M

Time setting

Range

1999s

Accuracy

(0.1%setting+1count)

Insulation resistance measurement

Range

0.099.9 M, 1002000 M

Accuracy

200M:(3%reading+3counts)

200M:(8%reading+8counts)

Ground Bond Resistance test

No load output voltage

<12V

Output current setting

Range

330A

Accuracy

(3%setting+0.2A)

Current range instruction

Optional: 3 ~ 64A test current

Current frequency setting

Range

Sine waveform 50Hz/60Hz

Accuracy

0.1%setting

Test time setting

Range

1999s

Accuracy

(0.1%setting+1count)

Result display mode

Ground resistance or voltage

Ground resistance display mode

Alarming limits setting

Resistance upper-limit range

3Aoutput current10A:10600 m

Resistance lower-limit range

0100 m

Compensation resistance setting

Range

0200 m, automatic testing, compensation can be set to ON/off

Ground bond resistance measurement

Range

10600 m

Accuracy

(3%reading+ 5counts)

Ground voltage display mode

Alarming limits setting

Voltage upper-limit range

307500 mV

Voltage lower-limit range

03000 mV

Compensation voltage setting

Range

01000 mV, automatic testing, compensation can be set to ON/off

Ground bond resistance measurement

Range

107500 mV

Accuracy

(3%reading+ 50mV)

Leakage Current test

Leakage current test type setting

Single phase load, static/dynamic leakage current

MD network selection

Standard IEC 60335-1 figure 4 network;Other test network Optional

Alarming limits Setting

Current upper-limit range

0.0509.999mA

Current lower-limit range

0.0005.000mA

Leakage current compensation setting

Range

0.0001.000mA, automatic testing, compensation can be set to ON/off

Time test setting

Range

1999s

Accuracy

(0.1%setting+1count)

Leakage current measurement

Range

0.0509.999mA

Accuracy

DC10kHz: (3%reading+0.010mA)

Output voltage measurement

Range

60280V(Phase voltage)

Accuracy

(0.5%reading+2counts)

Run Power Only forAN9651S(F)/AN9651F(F)/AN9651B(F)

Alarming limits setting

Power upper-limit range

66000W

Power lower-limit range

06000W

Test time setting

Range

1999s

Accuracy

(0.1%setting+1count)

Voltage measurement

Range

60280V(Phase voltage)

Accuracy

(0.5%reading+2counts)

Current measurement

Range

0.0303.999A, 4.0025.00A

Accuracy

(0.5%reading+2counts)

Active power measurement

Range

30.0199.9W:(0.5%reading+5W)

Accuracy

2006000W(Or2000W):(0.5%reading+30W)