Brand Name: | Ainuo |
---|---|
color: | blue |
Theory: | N |
Resolution: | 2% |
Size: | N |
Model Number: | AN9651S(F)AN9651F(F)AN9651B(F) |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
* Comply with CCC,IEC EN,VED,BS,UL,JIS standard
Requiements.
* Latest international standard:500VA AC Hipot
Capacity(AC 5KV/100mA),short-circuit output current exceeds 200mA.Built-in
Optional leakage current test network MD card,meeting requirements of different
Industrial standards Maximum test current of Ground Bond resistance is up to
64A
*6 in 1:AC Hipot,Insulation Resistance,Ground
Bond resistance,Leakage Current,Running Power,Low-Voltage Start.
Standby power consumption is optional for
AN9651F(F)and AN9651S(F),minimum is low to 0.50w,accuracy is 0.2%
* Simple operation:LED backlit screen
Display.Menu operation,Chiense/English langues,socket test fixture.
* Flexible configuration:Built in isolated
Transformer,AC frequency conversion power supply,frequency conversion power
Supply and industrial PC combiantion
* Satisfy lattest requirements:Follow the production line
Developing trends of comprehensive,fast,automation and information.Satisfy
Quality management,5s management and refid management requirements.
Spec.
AC Hipot test |
|||
Booster rated output capacity |
500VA(5000V/100mA) |
||
Booster maximum short-circuit current |
>200mA |
||
Output waveform |
Sine wave, <3%(Pure resistance,5000V/1mA),<3%(from empty load to full load) |
||
Output voltage setting |
Range |
5005000V |
|
Resolution |
5V |
||
Accuracy |
(3%setting+10V) |
||
Frequency setting |
Range |
50Hz/60Hz |
|
Accuracy |
0.1%setting |
||
Alarming limits setting |
Current upper-limit |
0.1099.99mA |
|
Current lower-limit |
0.0010.00mA |
||
Compensation current setting |
Range |
0.0010.00mA, automatic testing, compensation can be set to ON/off |
|
Time setting |
Range |
1999s |
|
Ramp up time range |
1100s |
||
Accuracy |
(0.1%setting+1count) |
||
Breakdown current alarm |
Range |
0.1099.99mA |
|
Accuracy |
(3%reading+3counts) |
||
Insulation Resistance test |
|||
Rated output capacity |
2VA(1000V/2mA) |
||
Output voltage regulation |
<3%(from no load to full load) |
||
Output voltage ripple |
<1% |
||
Output voltage setting |
Range |
DC 500Vor1000V |
|
Accuracy |
(3%setting+3counts) |
||
Alarming limits setting |
Resistance upper-limit range |
0.099.9 M,1002000M(If upper-limit is set to 0, it will not make adjudgment for upper Limit) |
|
Resistance lower-limit range |
0.399.9 M, 1002000M |
||
Time setting |
Range |
1999s |
|
Accuracy |
(0.1%setting+1count) |
||
Insulation resistance measurement |
Range |
0.099.9 M, 1002000 M |
|
Accuracy |
200M:(3%reading+3counts) |
||
200M:(8%reading+8counts) |
|||
Ground Bond Resistance test |
|||
No load output voltage |
<12V |
||
Output current setting |
Range |
330A |
|
Accuracy |
(3%setting+0.2A) |
||
Current range instruction |
Optional: 3 ~ 64A test current |
||
Current frequency setting |
Range |
Sine waveform 50Hz/60Hz |
|
Accuracy |
0.1%setting |
||
Test time setting |
Range |
1999s |
|
Accuracy |
(0.1%setting+1count) |
||
Result display mode |
Ground resistance or voltage |
||
Ground resistance display mode |
|||
Alarming limits setting |
Resistance upper-limit range |
3Aoutput current10A:10600 m |
|
Resistance lower-limit range |
0100 m |
||
Compensation resistance setting |
Range |
0200 m, automatic testing, compensation can be set to ON/off |
|
Ground bond resistance measurement |
Range |
10600 m |
|
Accuracy |
(3%reading+ 5counts) |
||
Ground voltage display mode |
|||
Alarming limits setting |
Voltage upper-limit range |
307500 mV |
|
Voltage lower-limit range |
03000 mV |
||
Compensation voltage setting |
Range |
01000 mV, automatic testing, compensation can be set to ON/off |
|
Ground bond resistance measurement |
Range |
107500 mV |
|
Accuracy |
(3%reading+ 50mV) |
||
Leakage Current test |
|||
Leakage current test type setting |
Single phase load, static/dynamic leakage current |
||
MD network selection |
Standard IEC 60335-1 figure 4 network;Other test network Optional |
||
Alarming limits Setting |
Current upper-limit range |
0.0509.999mA |
|
Current lower-limit range |
0.0005.000mA |
||
Leakage current compensation setting |
Range |
0.0001.000mA, automatic testing, compensation can be set to ON/off |
|
Time test setting |
Range |
1999s |
|
Accuracy |
(0.1%setting+1count) |
||
Leakage current measurement |
Range |
0.0509.999mA |
|
Accuracy |
DC10kHz: (3%reading+0.010mA) |
||
Output voltage measurement |
Range |
60280V(Phase voltage) |
|
Accuracy |
(0.5%reading+2counts) |
||
Run Power Only forAN9651S(F)/AN9651F(F)/AN9651B(F) |
|||
Alarming limits setting |
Power upper-limit range |
66000W |
|
Power lower-limit range |
06000W |
||
Test time setting |
Range |
1999s |
|
Accuracy |
(0.1%setting+1count) |
||
Voltage measurement |
Range |
60280V(Phase voltage) |
|
Accuracy |
(0.5%reading+2counts) |
||
Current measurement |
Range |
0.0303.999A, 4.0025.00A |
|
Accuracy |
(0.5%reading+2counts) |
||
Active power measurement |
Range |
30.0199.9W:(0.5%reading+5W) |
|
Accuracy |
2006000W(Or2000W):(0.5%reading+30W) |