Brand Name: | Ainuo |
---|---|
color: | blue |
Theory: | N |
Resolution: | 2% |
Size: | N |
Model Number: | AN9638H(F)AN9637H(F) |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Main features
* Latest international standard:Comply with
CCC,IEC,EN,VDE,BS,UL,JIS standard requirements,500VA WITHSTAND(AC
5KV/100mA),short-circuitoutput current exceeds 200mA,Ground resistance test
Current up to 64A,optional resistance or voltage mode.7 kinds of
Built-innetworking MD card for leakage contace current test,complying with
Multiple industrial standards.
Latest international standard: Comply with CCC, IEC, EN,VDE, BS, UL,JIS
Standard requirements. 500VA withstand (AC 5kV/100mA), short-circuit output
Current exceeds 200mA. Ground resistance test current up to 64A, optional
Resistance or voltage mode. 7 kinds of built-in networking MD card for leakage
Contact current test, complying with multiple industrial standards.
Intelligent test: 15 groups of test memories (group name editable),
8-step programming for each group. Product bar code reading and identification,
Automatically call the test group according to the model/specifications of the
Products tested. with U-disk to save test data timely.
Auto control: RS232/RS484/GPIB (four), bar code scanner interface, PLC
Interface, easily forming automation system.
Information management: optional electrical safety monitoring and control
System software (ESRS), realizing test process and data management, high test
Efficiency, convenient for analysis and tracing.
Simplified operation: LCD display,
Shortcuts, Chinese/English.
Order information:
AN9638H, 500VA(5000V/100mA) AC/DC Withstand voltage, ground test (64A).
AN9637H, 200VA(5000V/40mA) AC/DC Withstand voltage, ground test (32A).
Spec
AC Hipot test | ||
Rated output capacity |
AN9638H(F) |
500VA(5000V/100mA),Short circuit current >200mA |
AN9637H(F) |
200VA(5000V/40mA),Short circuit current >200mA | |
Output voltage setting |
Range,Accuracy |
1005000V,(2%setting+5counts) |
Output frequency setting |
Range,Accuracy |
50Hz or 60Hz,0.1%setting |
Alarm current limits setting |
Upper-limit range,Accuracy |
0.10100.00mA(or 40.00mA),(2%setting+5counts) |
Lower-limit range,Accuracy |
0.0009.999mA,(2%setting+5counts) | |
Time setting |
Range |
0.5999.9s(0 is infinite) |
Ramp up/down time range |
0.1999.9s | |
Accuracy |
(0.2%setting+1count) | |
Measurement |
Voltage range,Accuracy |
0.015.00kV,(1.5%reading+1count) |
Frequency range,Accuracy |
50Hz or 60Hz,0.1%reading | |
Current range,Accuracy |
0.10100.00mA(or 40.00mA),(2%reading+2counts) | |
Time range,Accuracy |
0.1999.9s,(0.2%reading+1count) | |
Output voltage waveform, distortion, regulation |
Sine wave,<2%(Pure resistance load),<2%setting+5V)(from empty load to full Load) | |
Start voltage setting |
(0%50%)Output voltage setting | |
Current compensation setting |
0.000~100.00mA(or 40.00mA),auto,Manual | |
Arc detection |
19 level,9 level is Optimally sensitive,0 is off | |
DC Hipot test | ||
Output voltage setting |
Range,Accuracy |
1006000VDC,(2%setting+5counts) |
Alarm current limits setting |
Upper-limit,Accuracy |
0~10000A,(2%setting+5counts) |
Lower-limit,Accuracy |
0.0~999.9A,(2%setting+5counts) | |
Time setting |
Range |
0.5999.9s(0 is infinite) |
Ramp up time range |
0.1999.9s | |
Ramp down time range |
0.3999.9s(0 is off) | |
Accuracy |
(0.2%setting+1 count) | |
Measurement |
Voltage range,Accuracy |
0.016.00VDC,(1.5%reading+1count) |
Frequency range,Accuracy |
0.010000uA,(2%reading+5count) | |
Current range,Accuracy |
0.1999.9s,(0.2%reading+1count) | |
Rated output capacity |
60VA(6000VDC/10mA) | |
Output voltage ripple, regulation |
<5%(Pure resistance load,6000V/10mA),<(2%setting+5V)(from empty load to full load) | |
Compensation current Setting |
0 ~200.0A,Auto, manual | |
Start voltage setting |
(0%50%)Setting output voltage | |
Charging current lower limit |
(0~3.500)A,Auto, manual | |
Discharge time |
200ms | |
Arc detection |
19 level,9 level is Optimally sensitive,0 is off | |
Insulation Resistance test | ||
Output voltage setting |
Range,Accuracy |
1002500Vdc,(2%setting+5counts) |
Alarm resistance setting |
Range |
19999M |
Accuracy |
100-499V,1~1000M,(8%setting+2counts) 1000~2000M,(12%setting+2counts) 500-2500V,1~199M,(2%setting+2counts), 200~999M, (5%setting+2counts) 1000~9999M, (15%setting+2counts) | |
Time setting |
Ramp up time range |
0.1999.9s |
Adjustment delay time |
0,0.5999.9s(0 is Infinite) | |
Test time range |
0,0.5999.9s(0 is Infinite) | |
Ramp down time range |
0.1999.9s | |
Accuracy |
(0.1%setting+0.1s) | |
Measurement |
Voltage range, accuracy |
1002500Vdc,(2%reading+5counts) |
Resistance range, accuracy |
19999M; 100-499V,1~1000M,(8%reading+2counts) 1000~2000M,(12%reading+2counts) 500-2500V,1~199M,(2%reading+2counts), 200~999M, (5%reading+2counts) 1000~9999M, (15%reading+2counts) | |
Time range,Accuracy |
0.1999.9s,(0.2%reading+1counts) | |
Charging current lower limit |
0~3.500A,Auto, manual | |
Discharge time |
200ms | |
Ground Bond test | ||
Rated output |
AN9638H(F) |
Max output current is 64A,Max testing resistance 600m,Open-circuit Voltage <12V |
AN9637H(F) |
Max output current is 32A,Max testing resistance 600m,Open-circuit voltage <12V | |
Output current setting |
Range,Accuracy |
2.032.0A(or 64A),(2%setting+5counts) |
Output voltage setting |
Range,Accuracy |
3.0~10.0V ,(2%setting+5counts) |
Output frequency setting |
Range,Accuracy |
Sine wave,50Hz or 60Hz,0.1%setting |
Alarm limits setting |
Resistance upper/lower limits |
2.0~10.6A:0.1~600m; 10.7~32.0A(or 64A):0.1~R m,among R=(6400 / set current value)m,When current range changs,Tester for automatic calculation range scope biggest |
Tolerance |
(2%setting+5counts) | |
Compensation resistance setting |
Range |
0100 m,Automatic measurement,on/off |
Test time setting |
Range,Accuracy |
0.5999.9s(0 stand for time infinite length);(0.2%setting+1count) |
Measurement |
Current range,Accuracy |
2.032.0A(or 64A),(2%reading+2counts) |
Voltage range,accuracy |
3.0~10.0V ,(2%reading+5counts) | |
Resistance range, accuracy |
10.0~99.9~100~600m;(2%reading+5counts) (64A current calculated method is same) | |
Time range,Accuracy |
0.5999.9s(0 stand for time infinite);(0.2%setting+1count) | |
Extended function | ||
Communication function |
Address setting |
0999 |
Baud rate setting |
300,1200,2400,4800,9600,192000 | |
Verification mode setting |
None,odd,even | |
Bar code scanning |
Bar code scanning function |
on/off |
Bar code length setting |
130 | |
Model identification number |
Start bit select 130,Max length 16 Bit | |
Function allocation explain |
Hardware interface is optional | |
Print function |
Printer type setting |
Stylus printer miniprinter |