Brand Name: | AME |
---|---|
discharge current: | 1st range: 0.5mA~0.1A, 2nd range: 0.1A~6A |
current measurement resolution: | 0.05% of FS |
discharge voltage range: | The two up&down head of clamp:1.0V, 2m clamp line: 1.5V |
voltage measurement resolution: | 0.05% of FS |
Model Number: | 4008-5V6A |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
BTS-5V6A Battery Testing System |
||||||||||
Description |
Product Specification |
|||||||||
AC Input |
AC 220V10% 50Hz |
|||||||||
Power |
425 |
W |
||||||||
Resolution |
AD: 16bit; DA: 16bit |
|||||||||
Input Impedance |
1M |
|||||||||
Voltage |
Measuring Range |
Charge: 25mV~5V |
|
|||||||
Discharge Min Voltage |
the two up&down head of clamp:1.0V, 2m clamp line: 1.5V |
|||||||||
Accuracy |
0.05% of FS |
|||||||||
Stability |
0.05% of FS |
|||||||||
Current |
Each channel outputRange |
1st range: 0.5mA~0.1A 2nd range: 0.1A~6A |
||||||||
Accuracy |
0.05% of FS |
|||||||||
CV cut-off current |
1st range:0.02mA 2nd range:12mA |
|||||||||
Stability |
0.05% of FS |
|||||||||
Power |
Output Power Per Channel |
30W |
||||||||
Stability |
0.1% of FS |
|||||||||
Time |
Rise Time |
1ms (0~Full Range) |
||||||||
Step Time |
(365*24)hour/step Time Format 00:00:00 (h:min:s) |
|||||||||
Data Acquisition |
Intervals |
Min.Time Interval t:100ms |
||||||||
Min.Voltage Interval U: 10mV |
||||||||||
Min.Current Interval I: 1st :0.02mA 2nd:12mA |
||||||||||
Frequency |
10Hz |
|||||||||
Charge |
Mode of Operation |
CCC, CVC, CC & CVC,CPC |
||||||||
End Conditions |
Voltage, Current, Test Time, Capacity,-V |
|||||||||
Dischar |
Mode of Operation |
CCD, CPD,CRD |
||||||||
|
End Conditions |
Voltage, Current, Test Time, Capacity,-V | ||||||||
Pulse |
Charge |
CCC,CPC | ||||||||
Discharge |
CCD,CPC | |||||||||
Min Pulse Width |
500ms | |||||||||
Pulse no. |
Single pulse step support 32 different pulse | |||||||||
Automated Switch |
Automated switch from charge to discharge for each pulse | |||||||||
End Condition |
Voltage, Test Time | |||||||||
DCIR test |
Support custom getting point then DCIR calculate |
|||||||||
Cycle |
Cycles |
65535 | ||||||||
Steps |
254 | |||||||||
Nested Function |
Max three Levels of loops | |||||||||
Protective Function |
Software |
Power-off data Protection | ||||||||
off-line Operating | ||||||||||
User-defined Safety(upper and Lower)tolerance of Current, Voltage and delay time | ||||||||||
IP Protection level |
IP 20 protection level |
|||||||||
Channel Features |
Independent pairs of Closed loop for Constant Current Source and Constant Voltage Source |
|||||||||
Channels |
Independent Control |
|||||||||
Detection and Sampling |
4-wire Connecting |
|||||||||
Noise Density |
<85dB |
|||||||||
Data Management |
MYSQL Database |
|||||||||
Communication Means |
TCP/IP Protocol |
|||||||||
SOS |
Windows 7 |
|||||||||
Export Formats |
EXCEL2003, 2010,TXT |
|||||||||
Communication Interface |
Internet |
|||||||||
Number of Channels Per Cabinet |
8 |
|||||||||
Current leakage |
0.0000005mA |
|||||||||
Operating Environment |
||||||||||
Description |
Product Specification |
|||||||||
Operating Temperature |
0~40 |
|||||||||
Storage Temperature |
-10~50 |
|||||||||
Operating Humidity |
70% RH |
|||||||||
Storage Humidity |
80% RH |
|||||||||
Description |
Product Specification |
|||||||||
Holder |
Universal Holder |
|||||||||
|
|
|
|
|
||||||
Universal Holder |
Alligator Holder |
Polymer Holder |
Wiring Terminal |
|||||||
Dimensions (W*D*H)(mm) |
3U(164),480*330*130 |