Brand Name: | Readeagle |
---|---|
Type: | instrument |
Properties: | The Basis of Surgical Instruments |
Material: | Metal |
Voltage: | 100~240V |
Place of Origin: | China (Mainland) |
Model Number: | Aries 2700 |
Instrument classific: | Class III |
Respiration mode: | IPPV / SIMV / Sign / Manual |
Tidal Volume: | 50-1600ml |
Trigger Pressure: | -20-20cmH2O |
Pressure Setting: | 1-60cmH2O |
Display:: | 5.5" SNT screen |
Patient type:: | Adult / Pediatric |
Quick Details
Specifications
Special Feature
5.5" SNT screen, two waveforms are showed at the same time.
Aluminium alloy frame, durable and elegant.
Double vaporizer station, selectatec compatible.
Independent Anesthesia Ventilator, could be driven by medical air.
Classical Flowmeter of 4 tubes.
Linear design, could be easily upgraded with functions: eg adding Multi-parameter Monitor, CO2 Monitor, AMIS System.
Working Mode:
Semi-open, Semi-closed or Closed system
Gas Supply Pressure
O2: 0.27Mpa-0.55Mpa
N2O: 0.27Mpa-0.55Mpa
Flow meter
4 Tube: 2 x O2 Tube, 2 x N2O Tube
O2 Tube: 0L/min-1L/min-10L/min
N2O Tube: 0L/min-1L/min-10L/min
O2 and N2O Linkage Device, keep oxygen concentration not lower than 25%
Oxygen flush: 25L/min-75L/min
Safety Function
When airway pressure reach 6 kPa, APL valve will automatically release gas.
When airway pressure reach 6 kPa, the Bellows will stop sending gas to patient.
Monitoring parameters (under Manual and Ventilation):
Tidal Volume Minute Ventilation
Airway Pressure FiO2 (Optional)
Alarm parameters (Audible and/or visual signal):
Airway Pressure high/low limit
FiO2 high / low limit
Low O2 Supply Pressure (when O2 Supply Pressure is lower than 0.15Mpa, will arouse Audible Alarm)
N2O automatic Cutoff Alarm
Technical Parameter
Patient type |
Adult / Pediatric |
Driven mode |
Pneumatically Driven. Electronically Controlled
|
Respiration mode |
IPPV / SIMV / Sign / Manual |
Tidal Volume |
50-1600ml |
Respiratory frequency |
1-65bpm |
I:E ratio |
8:1-1:8 |
Pressure Setting |
1-60cmH2O |
Trigger Pressure |
-20-20cmH2O |
Waveforms (under Manual and Ventilation) |
P-t, V-t |
Mains |
100-240V, 50/60Hz |
Battery |
12V DC, minimum 120 min (if with) |
Power consumption |
50W |
Circle Absorber
Upgraded integrated Circle Absorber, with twins large volume CO2 canister, high CO2 absorbing efficiency.
with non-return respiratory valve and expiratory valve on it, avoid gas back flowing.
with " Manual / Ventilation" switch on it, easily and quickly change.
with APL valve on it, the airway pressure could be adjusted freely.
Anesthesia Vaporizer
the agent output is continuous, stable, and precise
Automatic compensation for Temperature, Flow and Pressure
Flow Range: 0.2-15L/min
Temperature Range: Operating 15-35
Agent: Halothane, Enflurane, Isoflurane, Servofluane for choice
Dimensions
Size: 92*62*144cm
Optional
Yoke Device
Patient Monitor
CO2 Monitor
AMIS
AGSS
FiO2