Brand Name: | Readeagle |
---|---|
Type: | instrument |
Properties: | The Basis of Surgical Instruments |
Material: | Metal |
Voltage: | 100~240V |
Place of Origin: | China (Mainland) |
Model Number: | Aries 2500 |
Instrument classification: | Class III |
Application: | Adult, Pediatric |
Tidal Volume: | 20-1600ml |
Display: | 10.4 TFT color screen |
Respiration mode: | IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO |
Trigger Pressure: | -20-20cmH2O |
I:E ratio: | 8:1~1:8 |
Quick Details
Specifications
Technical Parameter
Screen |
10.4" TFT color touch screen (Sharp brand) with high definition and colorful |
Driven mode |
Pneumatically Driven. Electronically Controlled
|
Respiration mode |
IPPV/VCV/PCV/SIMV/Sign/Manual/Standby/Demo |
Tidal Volume |
20-1600ml |
Respiratory frequency |
1-65bpm |
I:E ratio |
4:1-1:4 |
Pressure Setting |
1-60cmH2O |
Trigger Pressure |
-20-20cmH2O |
Inspiration Plateau |
0-50% Ti |
Working Mode |
Semi-open / Semi-closed / Closed |
Gas SupplyPressure |
O2: 0.27MPA-0.55Mpa N2O:0.27MPA-0.55Mpa Air:0.27MPA-0.55Mpa |
Oxygen flush |
25L/min-75L/min |
Electrical Specification Mains |
Mains: 100-240V, 50/60Hz Battery: 12V DC, minimum 120 min (if with) Power consumption:50W |
Special Feature
Aluminium alloy frame, durable and elegant.
Double vaporizer station, selectatec compatible.
Waveform: P-t, F-t, V-t. Loops: F-v, V-p
Classical Flowmeter of 5 tubes.
3 big drawers, with lock
Linear design, could be easily upgraded with functions: eg adding Multi-parameter Monitor, CO2 Monitor, AMIS System, etc.
Advanced proportional valve (SMC brand) ensures accurate tidal volume output.
Use advanced differential pressure sensor (Honeywell brand) to monitor tidal volume.
Apply for adult and pediatric, especially independent pediatric mode for patient of min.5kgs
Safety Function
When airway pressure reach 6 kPa, APL valve will automatically release gas.
When airway pressure reach 6 kPa, the Bellows will stop sending gas to patient.
Pressure Protection Function:
When use PCV respiratory mode, the inspiration pressure could be pre-set.
Pr Volume Protection Function:
When use VCV respiratory mode, the tidal volume could be pre-set.
Monitoring parameters (under Manual and Ventilation)
Tidal Volume Respiratory Frequency
Minute Ventilation FiO2 Respiration Mode
Airway Pressure (Ppeak, Pplateau) Lung Compliance
Alarm parameters (Audible and/or visual signal)
Airway Pressure high/low limit
FiO2 high / low limit
Minute Ventilation high/low limit
Low O2 Supply Pressure (when O2 Supply Pressure is lower than 0.15Mpa, will arouse Audible Alarm)
N2O automatic Cut off Alarm
Low O2 Supply Pressure (when O2 Supply Pressure is lower than 0.15Mpa, will arouse Audible Alarm)
N2O automatic Cut off Alarm
Anesthesia Vaporizer
the agent output is continuous, stable, and precise
Automatic compensation for Temperature, Flow and Pressure
Flow Range: 0.2-15L/min
Temperature Range: Operating 15-35
Agent: Halothane, Enflurane, Isoflurane, Sevofluane for choice
Circle Absorber
Classical CO2 Circle Absorber with twins canisters.
with non-return respiratory valve and expiratory valve
with " Manual / Ventilation" switch, easily and quickly change.
with APL valve, the airway pressure could be adjusted freely.
Flowmeter
Reliable and practical mechanical flowmeter
5 Tube: 2 x O2 Tube, 2 x N2O Tube, 1 x Air Tube
O2 Tube: 0L/min-1L/min-10L/min
N2O Tube: 0L/min-1L/min-10L/min
Air Tube: 0L/min-10L/min
O2 and N2O Linkage Device, keep oxygen concentration not lower than 25%
Pediatric Bellows
PEEP Patent in China, including adult size and pediatric size
Yoke
O2/N2O Yoke device(Optional). When main gas supply is failed, the backup gas supply can be automatically started
Dimensions
Size: 94*62*144cm
Optional
Yoke Device
Patient Monitor
CO2 Monitor
AMIS
AGSS
PEEP
Circle absorber heating function