Product Main

Quick Details

Brand Name: Readeagle
Type: instrument
Properties: The Basis of Surgical Instruments
Material: Metal
Voltage: 100~240V
Place of Origin: China (Mainland)
Model Number: Re902-C1
Instrument classification: Class III
Display: 8.4"color touch screen and button operation
I:E Rate:: 8:1-1:8
Breathing Frequency: 1-65BPM
O2 Flush: 25-75L/min
Working Mode:: Semi-open, Semi-closed and Closed
Tidal Volume:: 100-1600ml
Driven Mode: Pneumatically dirven and electronically controlled
Respiration Mode: IPPV, SIMV, Sigh, Manual, Demo, Standby

Specifications

High quality multifunction Anestesia machine Clinical Anesthesia equipment with ventilator

Technology Specification:

Patient

Suitable for Adult and Pediatric

Display

8.4"color touch screen and button operation

Optional: 15.1"color touch screen

Frame

Metal alloy frame, with plastic spray process, durable and elegant. Two big drawers, convenient for different articles storage

Flowmeter

Classical Flowmeter of 5 tubes, with O2 and N2O Linkage Device, and make sure Oxygen Concentration not lower than 25%.

O2 Flow Rate: 0-1L/min, 1-10L/min

N2O Flow Rate: 0-1L/min, 1-10L/min

Air Flow Rate: 0-10L/min

O2 Flush

25-75L/min

Circle Absorber

Classical CO2 Circle Absorber with twins canister

with non-return respiratory valves

with APL valve, the airway pressure could be adjusted freely

with " Manual / Ventilation"  one switch

  Canister Volume: each 1000ml (1000g soda lime); total 2000ml (2000g soda lime)

High Precise Anesthesia Vaporizer

Concentration Scope: 0.2-5VOL%

Flow Scope: 0.2-15L/min

Temperature Scope: 15-35

Anesthesia Vaporizer, automatic compensation for Temperature, Flow and Pressure.

Anesthesia Agent: Halothane, Enflurane, Isoflurane, Sevofluane for choice.

Monitoring Parameters

Tidal Volume

Respiratory Frequency

Minute Ventilation

FiO2

Airway Pressure (Ppeak, Ppeep)

Respiration mode

Monitored Waveform

P-t,  F-t

Alarm Parameters

Airway Pressure high / low limit

FiO2 high/low limit

Minute Ventilation high/low limit

Breathing Frequency high/low limit

AC failure

O2 supply low

Alarm silence

Gas supply Pressure

O2  N2O  Air  

O2:  0.28-0.60Mpa

N2O:  0.28-0.60Mpa

Air:  0.28-0.60Mpa

Working Mode

Semi-open, Semi-closed or Closed

Driven Mode

Pneumatically driven and electronically controlled

Respiration Mode

IPPV, SIMV, Sigh, Manual, Demo, Standby

IPPV(Pressure Protection)

SIMV((Pressure Protection, Time protection)

Breathing Frequency

1-65BPM

Tidal Volume

100-1600ml

I:E Rate

8:1-1:8

Pressure Limit

Min. Pressure Limit: 1cmH2O

Max Working Pressure Limit: 60cmH2O

Airway Pressure Monitored

-10-60cmH2O

PEEP

0-20cmH2O (Mechanic)

Anesthesia Ventilator System Compliance

4ml/100Pa

Power Supply

220V, 50Hz; or 110V, 60Hz

Power: 90VA

Optional

Patient Monitor. YOKE  .CO2 Monitor  . AGSS