Nominal Capacity: 135AH
Weight: 38KGS
Size: 483*170*240MM
Usage: UPS
Brand Name: protettore
Maintenance Type: Free
Sealed Type: Sealed
Voltage: 12v
Model Number: NP12135
Place of Origin: China (Mainland)
Color: White
Battery plate: calcium alloy
Battery case: ABS engineering plastic
Life time: 10 years

Specifications

Advantage

1.the battery is full of power when it's out of factory, no need To use liquid charge;

2.No memory, no need to discharge battery use, suitable for Circuit design;

3.by high partition, adsorption and strong;

4.There is no flowing liquid (poor liquid), does not leak acid and Free Upside down,

5.Comply with environmental requirements, ease of use,

6.the use of lead-calcium alloys, battery self-discharge is very low,

7.Easy storage, less maintenance;

8.Using ABS plastic shell and valve technology for safe use.

 

Application

the lead acid battery 12v135ah can be used in UPS, light, magnetic Lifting equipment and so on.

 

Battery Characteristic

Nominal Voltage

12V

Nominal Capacity(10h rate)

135Ah

Size

Total Height

240mm

Length

483mm

width

170mm

Height

240mm

Weight

38kg

Rated Capacity                       25C(77F)

10 hour Rate

135Ah

 

 

5 hour Rate

120Ah

1 hour Rate

90Ah

Internal Resistance

in full Charge status 25C(77F)

3.8m

Capacity at different temperature(10h)

40C(104F)

102%

25C(77F)

100%

0C(32F)

85%

-15C(5F)

65%

Self Discharge     25C(77F)

Capacity after 3 months

91%

Capacity after 6 months

82%

Capacity after 12 months

64%

Mode of Charge (constant voltage)       25C(77F)

Cycle-use

Initial Charging current less than16.5A,                    voltage14.40-14.80V

Float-use

No Limit on Initial charging current  Voltage13.50-13.80V

 

 Notice

1         Don't near the hot source and Don't under the sunshine.

2         Don't charge in the sealed Container.

3         No short Circuit. It should be addition charge if you don't use, and single charge Per three months, to avoid irreversible sulfating. the battery should be Changed when the battery jar broken or the electrolyte omitted, to avoid acid Corrosion.

4         Don't store in the space of Acid gas.

5         You Should be careful and regular check when use the battery. to avoid the battery Don't work. You should change the battery if the capacity is not full Or has been damage, especially after one year using.

6         Don't put the battery in the Fire, or it will explode.

7         Please Use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

8         Don't clean the battery by Using the organic solution. (e.g. Petrol)


12v135ah Valveregulated sealed lead acid battery12v135ah Valveregulated sealed lead acid battery12v135ah Valveregulated sealed lead acid battery