Product Main

Quick Details

Nominal Capacity: 1.3AH
Weight: 0.52KGS
Size: 97*43*52MM
Usage: UPS
Brand Name: protettore
Maintenance Type: Free
Sealed Type: Sealed
Voltage: 12v
Model Number: NP1213
Place of Origin: China (Mainland)
Color: Black
Battery plate: Lead calcium alloy
Battery case: ABS engineering plastic
Life time: 10 years

Specifications

                       Description of 12v1.3ah Battery

Application

Maintenance free storage battery 12v1.3ah is used for instruments, Anti-theft alarm system, fire alarm system, automatic door and so on.

 

Advantage

1. the battery is full of power when it's out of factory, no need To use liquid charge;

2. No memory, no need to discharge battery use, suitable for Circuit design;

3. by high partition, adsorption and strong;

4. There is no flowing liquid (poor liquid), does not leak acid and free Upside down,

5. Comply with environmental requirements, ease of use,

6. the use of lead-calcium alloys, battery self-discharge is very low,

7. Easy storage, less maintenance;

8. Using ABS plastic shell and valve technology for safe use.

 

Battery Characteristic

Nominal voltage

12V

Nominal capacity(20h rate)

1.3Ah

Size

Total height

57mm

Length

98mm

width

43mm

Height

52mm

Weight

0.51kg

Rated capacity                       25C(77F)

20 hour rate(0.065A)

1.3Ah

10 hour rate(0.12A)

1.2Ah

5 hour rate(0.22A)

1.10Ah

1 hour rate(0.78A)

0.78Ah

Internal resistance

in full charge status 25C(77F)

75m

Capacity at different temperature(10h)

40C(104F)

102%

25C(77F)

100%

0C(32F)

85%

-15C(5F)

65%

Self discharge     25C(77F)

Capacity after 3 months

91%

Capacity after 6 months

82%

Capacity after 12 months

64%

Mode of charge (constant voltage)       25C(77F)

Cycle-use

Initial charging current less than0.52A,                    voltage14.10-14.40V

Float-use

Initial charging current less than 0.2A voltage13.50-13.80V

 

Notice

1         Don't near the hot source and Don't under the sunshine.

2         Don't charge in the sealed Container.

3         No short Circuit. It should be addition charge if you don't use, and single charge Per three months, to avoid irreversible sulfating. the battery should be Changed when the battery jar broken or the electrolyte omitted, to avoid acid Corrosion.

4         Don't store in the space of Acid gas.

5         You Should be careful and regular check when use the battery. to avoid the battery Don't work. You should change the battery if the capacity is not full Or has been damage, especially after one year using.

6         Don't put the battery in the Fire, or it will explode.

7         Please Use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

8         Don't clean the battery by Using the organic solution. (e.g. Petrol)




12V13AH Sealed lead acid rechargeable battery

12V13AH Sealed lead acid rechargeable battery