| Rated Power: | 100KW |
|---|---|
| Frequency: | 50HZ 60HZ |
| Speed: | 1500turn 1800turn |
| Output Type: | AC Three Phase |
| Brand Name: | cummins |
| Rated Current: | 180A |
| Rated Voltage: | 400/230V |
| Model Number: | 100GF |
| Place of Origin: | China (Mainland) |
| color can be selected: | Black, green, red and yellow |
Quick Details
Specifications
Diesel generator 100kw with cummins engine 3phase 4wire
Diesel Engine |
Model |
6BTA5.9-G2 |
Brand |
Cummins | |
Type |
water-cooled, 4-stroke, direct injection, wet cylinder liner | |
Rated Power(kW) |
106 | |
Rated Speed(RPM) |
1500 | |
Intake Type |
Turbocharged | |
No.of Cylinder |
6.L | |
Bore x Stroke(mm) |
102*120 | |
Compression Ratio |
16.8:1 | |
Mechanical Governor Rate |
5% | |
Electronic Governor Rate |
1% | |
Noise Level (dBA) |
96 | |
Exhaust Temperature(C) |
601 | |
Lub oil Capacity(L) |
16.4 | |
Reted Fuel consumption |
27.5L | |
Displacement(L) |
5.88 | |
Starting Method |
DC 24V Electric motor | |
Governing Type |
Elecrtical Governor | |
Alternator |
Brand |
XINGNUO |
Model |
XN274DS | |
Rated Power(kW) |
100 | |
Voltage Regulation |
1 | |
Excitation Type |
Brushless | |
Insulation Class |
H |
1.Alternator Brand:Stamford,Marathon ,MECC, Copy Stamford,Faraday,and other brand
2..Controller:DSE ,SMARTGEN
1)Automatic control panel: use Smartgen or DSE controller: with
Automatic start, automatic stop; disply current, voltage, frequency, power,
Power factor, oil temperature, water temperature, oil pressure. Automatic
Protection function: overload, short circuit, high water temperature, low oil pressure,
Oil temperature and overspeed protection function;
2)Switch: the French model high beauty technology, small size,
Impact resistance, large current, high sensitivity, short trnsition time, etc.
3)Function: after the power grid, the controller signal launch, 10
Seconds to start the generator set (time can be adjusted 3 to 30 seconds)
Switch switch to power generation side. after the mains calls, controller
Signal downtime, delay 3 minuts downtime generator speed down.
3.ATS:
1)automatic control panel: use Smartgen 6120 LCD controller: with Automatic start, automatic stop; display current, voltage, frequency, power, Power factor, oil temperature, water temperature, oil pressure. Automatic Protection function: overload, short circuit, high water temperature, low oil Pressure, oil temperature and overspeed protection function;automatic Protection function: with overload, short circuit, high temperature, low oil Pressure, under voltage, oil temperature, downtime, overspeed protection function
2)Automation controller: the LCD panel: display current, voltage, Frequency, control of generating set automatic start, automatic stop and fault Alarm.
3)Switch: the French model high beauty technology, small size, Impact resistance, large current, high sensitivity, short transition time, etc.
4)Function: after the power grid, the controller signal launch, 10 Seconds to start the generator set (time can be adjusted 3 to 30 seconds) Switch switch to power generation side. after the mains calls, switch to the Mains switch, and the controller signal downtime, delay 3 minutes downtime Generator speed down.
4.Warranty
A, One year after installation;
B, 1000 running hours (accumulated); subject to the earlier one.
C,the Spare parts can be provided free within one year.