Product Main

Quick Details

After-sales Service Provided: Engineers available to service machinery overseas
Certification: ce
Weight: 500kg
Brand Name: HOPU
Condition: New
Dimension(L*W*H): 1.5x1.2x1.7
Power(W): 20 to 60
Voltage: 380
Usage: Transformer Oil
Model Number: zyd
Place of Origin: China (Mainland)
Working Pressure: 0.03
Flow: 100LPM
material: stainless steel

Specifications

HOPU ZYD-I Transformer Oil Regeneration and Reclamation System

 

as transformer oil ages, it oxidizes and begins to break down. during this time, oil purification which effectively removes moisture, solids and gaseous contamination will not be able to remove other by-products from the aging transformer oil. The by-products of the degradation process include acids, aldehydes, and peroxides, which bind together to form sludge.

 

Sludge attacks the cellulose insulation, inhibits oil flow and traps heat inside the transformer. Eventually the dielectric gap will be bridged, thus, resulting in failure of the transformer.

Used Transformer Oil Regeneration System Insulation Cable Oil Reclamation Machine transformer oil reconditioner

Oil Regeneration Extends Transformer Unit Life

 

Deding mobile regeneration system restores transformer oil by removing acidity, sludge, soluble oil decay products and improves oil colour with Fullers earth treatment technology. When the treatment is complete, the regenerated oil meets or exceeds international standards for new oil with lower acidity and improved tan delta, interfacial tension, and oxidation stability. the cellulose insulation and internal components of the transformer also benefit from the flushing effect of multiple passes of hot regenerated oil, which helps remove decay products and sludge from internal surfaces.


Used Transformer Oil Regeneration System Insulation Cable Oil Reclamation Machine transformer oil reconditioner

Advantages of Oil Regeneration

 

Extends the transformer life by restoring the qualities of the transformer oil to be similar to new oil condition

 

Oil Regeneration is much less costly than changing new oil

 

Minimal downtime as a result no revenue loss as Oil Regeneration can be performed 'on-inline or live'/ energized transformer

 

Environmentally friendly as the existing oil is reused. There will also be no hazard from oil spills and PCB contamination, including the trouble with the disposal of old oil

 

 

Oil Regeneration removes the sludge build up and deposited on the internal core and coils of the transformer, which a traditional oil change will not

 

Oil Regeneration can be continuously performed in most weather conditions and will not run the risk of exposing the internal transformer core to adverse weather conditions during an oil change

Used Transformer Oil Regeneration System Insulation Cable Oil Reclamation Machine transformer oil reconditioner

Technical Parameters

Parameter Unit ZYD-I-30 ZYD-I-50 ZYD-I-100 ZYD-I-150 ZYD-I-200 ZYD-I-250 ZYD-I-300
Flow rate L/h 1800 3000 6000 9000 12000 15000 18000
Working vacuum MPa -0.07~-0.099
Working pressure MPa 0.5
Temperature 30 ~ 80
Power   3 ph 380V 60Hz (or please contact HOPU'S presentives)
Working noise DB(A) 60 65 70 75 78 80 85
Heating power kW 30 36 48 60 80 108 120
Total power kW 36 44 54 66 93 120 135
Oil Inlet/Outlet mm 32 32 42 42 48 60 76
Weight Kg 850 1000 1200 1600 2200 2600 3000
Size L,mm 1050 1100 1200 1450 1600 1800 1900
W,mm 750 800 950 950 1100 1200 1200
H,mm 1350 1400 1500 1650 1800 1900 1900

Oil Index after Treated by ZYD-I Machine

Item Unit after treatment
Breakdown Voltage kV 75
Moisture content PPM 3
Gas content % 0.1
Impurity size Micron 0.5 (no free carbon)
IFT Dynes/cm 40
Acid value Mg KOH/g 0.03
Dielectric loss factors Tg(90C) 0.001
Colour L 0.5